background image

WARNING! – Risk of Hand Arm Vibration Injury.

This tool may cause Hand Arm Vibration Syndrome if its use is not managed adequately.

This tool is subject to the vibration testing section of the Machinery Directive 2006/42/EC.

This tool is to be operated in accordance with these instructions.

Measured vibration emission value (a):. . . . . . . . . . .8.27 m/s²

Uncertainty value (k):. . . . . . . . . . . . . . . . . . . . . . . . . .  1.5 m/s²

Please note that the application of the tool to a sole specialist task may produce a different average vibration emission. We recommend that a

specific evaluation of the vibration emission is conducted prior to commencing with a specialist task.

A health and safety assessment by the user (or employer) will need to be carried out to determine the suitable duration of use for each tool. 

NB: 

Stated Vibration Emission values are type-test values and are intended to be typical. 

Whilst in use, the actual value will vary considerably from and depend on many factors.  

Such factors include; the operator, the task and the inserted tool or consumable. 

NB:

 ensure that the length of leader hoses is sufficient to allow unrestricted use, as this also helps to reduce vibration.

The state of maintenance of the tool itself is also an important factor, a poorly maintained tool will also increase the risk of Hand Arm Vibration 

Syndrome.

Health surveillance.

We recommend a programme of health surveillance to detect early symptoms of vibration injury so that management procedures can be modified 

accordingly.

Personal protective equipment.

We are not aware of any personal protective equipment (PPE) that provides protection against vibration injury that may result from the 

uncontrolled use of this tool. We recommend a sufficient supply of clothing (including gloves) to enable the operator to remain warm and dry and 

maintain good blood circulation in fingers etc. Please note that the most effective protection is prevention, please refer to the Correct Use and 

Maintenance section in these instructions. Guidance relating to the management of hand arm vibration can be found on the HSC website 

www.hse.gov.uk - Hand-Arm Vibration at Work.

 

Original Language Version

© Jack Sealey limited

C

P18VRP    Issue 1    16/09/19

Содержание CP18VRP

Страница 1: ...l A Connect the BROWN live wire to the live terminal L B Connect the BLUE neutral wire to the neutral terminal N C After wiring check that there are no bare wires and ensure that all wires have been correctly connected Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight 8 8 DO NOT connect either wire to the earth terminal Sealey recommend that repa...

Страница 2: ...he polisher where there are flammable liquids solids or gases such as paint solvents etc 8 8 DO NOT allow children to operate the polisher 8 8 DO NOT operate the polisher if any parts are missing as this may cause failure and or personal injury 8 8 DO NOT hold unsecured work piece in your hand 8 8 DO NOT leave the polisher operating unattended 8 8 DO NOT carry the polisher with your finger on the ...

Страница 3: ...e the tool is thoroughly dry before using it 5 2 5 If available use clean dry compressed air to blow through the ventilation holes where applicable 5 3 LUBRICATION 5 3 1 Lightly lubricate all moving parts at regular intervals with a suitable lubricant 5 4 STORAGE 5 4 1 Store this tool carefully in a secure dry place out of the reach of children WARNING Risk of Hand Arm Vibration Injury Original La...

Страница 4: ...nserted tool or consumable NB ensure that the length of leader hoses is sufficient to allow unrestricted use as this also helps to reduce vibration The state of maintenance of the tool itself is also an important factor a poorly maintained tool will also increase the risk of Hand Arm Vibration Syndrome Health surveillance We recommend a programme of health surveillance to detect early symptoms of ...

Страница 5: ... by Jack Sealey Ltd Being the responsible person appointed by the manufacturer Signed Date Name Position Place Bury St Edmunds Cordless Rotary Polisher Ø150mm 18V Li ion CP18VRP v1 2014 30 EU EMC Directive 2006 42 EC Machinery Directive 2011 65 EU RoHS Directive References to harmonised standard s EN 55014 1 2017 EN 55014 2 2015 EN 60745 1 2009 A11 2010 EN 60745 2 3 2011 A13 2015 15 October 2019 S...

Страница 6: ...t to alter data specifications and component parts without prior notice There may be alternative versions of this product please contact us should you require this information IMPORTANT No liability is accepted for incorrect use of product Spare parts must be fitted by a competent person WARRANTY Guarantee is 12 months from purchase date proof of which will be required for any claim Parts Informat...

Страница 7: ...lt M4 X 14 Zinc 4 CP18VRP 04 Front Cover 5 B 6201 2RS Bearing 6201 2rs 6 DAS150T V3 36 Rd Head S T Screw M4 X 12 Black 7 CP18VRP 07 Gear Large 8 CP18VRP 08 Axis Circlip 12mm 9 B 696ZZ Bearing 696zz 10 ER1700P V2 53 Rd Head S T Screw M4 X 16 Black 11 CP18VOP 24 Gear Case 12 CP18VRP 12 O Ring 13 CP18VOP 26 Self Lock Button Spring 14 CP18VOP 27 Self Lock Button 15 CP18VRP 15 Self Lock Button Clip 16 ...