background image

0-12.7MM(0-0.5”) DIGITAL EXTERNAL 

MICROMETER

MODEL NO: 

AK9638D

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these 

instructions, and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  SAFETY

 

‰

WARNING!

 Ensure Health and Safety, local authority and general workshop practice regulations are adhered to when using tools and 

equipment.

 

8

DO NOT

 use micrometer if damaged.

 

9

Maintain micrometer in good and clean condition for best and safest performance.

 

9

Keep the work area clean, uncluttered and ensure there is adequate lighting. 

 

9

Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.

 

9

Keep children and unauthorised persons away from the work area.

 

8

DO NOT

 use the micrometer for any purpose other than for which it is designed.

 

8

DO NOT

 get micrometer wet or use in damp or wet locations, or areas where there is condensation. Keep micrometer clean and dry using 

a dry cotton cloth only.

 

8

DO NOT

 dip or submerge the micrometer in any type of liquid.

 

8

DO NOT

 expose calliper to bright sunlight or dust.

 

8

DO NOT

 dis-assemble micrometer. The micrometer must be checked by qualified service personnel only.

 

8

DO NOT

 apply any voltage to the micrometer i.e. with an electric marker pen.

 

9

The micrometer is a precision instrument, treat with care, avoid using force and do not subject to knocks or shocks.

 

9

Take particular care not to damage or scratch the scale surface.

 

9

Use micrometer in reasonably constant temperature conditions of approximately 20ºC.

2.  INTRODUCTION

Digital micrometer with spring loaded satin chrome pin. Easy-to-read LCD digital display with auto off feature. Zero display in any position for 

relative and tolerance readings. Display switchable between Metric and Imperial units.

3.  SPECIFICATION

Model No: ................................... AK9638D

Accuracy: ..........................±0.03mm(0.001”)

Battery:  .........................1 x LR44 (supplied)

Graduation: .......................0.01mm(0.0005”)

Range:  ............................ 0-12.7mm(0-0.5”)

4.  OPERATION

 

‰

  

WARNING!

 Ensure that you have read and understood Section 1 safety instructions before commencing.

4.1. 

  

Ensure all measuring surfaces are clean and then turn on micrometer by pressing on/off control. Wait at least one second before use.

4.2. 

  

If read-out does not show zero when micrometer is in closed position, reset by pressing zero control.

4.3. 

  

Select inch or mm units, as required, with the metric/imperial selector. Check that display shows the required units.

4.4. 

  

Retract the measuring pin by pressing the red lever above the display. Introduce the object to be measured into the measuring space and allow  

 

the pin to close onto the object so that it is between the end of the pin and the measuring pad.

4.5. 

  

Measurements will now be shown directly on the LCD display.

4.6. 

  

A new zero may be obtained, at any open position for relative and tolerance readings, by pressing the zero control. 

AK9638D  Issue 3 (4) 02/07/2020

Original Language Version

© Jack Sealey Limited

Refer to 

instructions

fig.1

1  Measuring Pad 

5  Measuring lever 

9  Battery Cover 

2  Measuring Space 

6  LCD Display 

 

   

 

 

3  Measuring Pin 

7  On/Off Control 

4  Metric/Imperial Selector 

8  Zero Button