Sealey AK458DX.V4 Скачать руководство пользователя страница 3

6.2.    

eMptying

6.2.1.   

ensure that drain pan valve (fig.6.2) is closed and hand wheel (fig.6.1) is tight. 

6.2.2.   

Attach the end of the drain hose to a suitable waste oil container (fig.6).

6.2.3.   

open ball valve tap (fig.6.5).

6.2.4.   

Connect air supply at a pressure of 0.45bar to coupling (fig.6.4) and open valve 3 (fig.6.3).

6.2.5.   

After the fluids have been transferred from the tank close valve 5 (fig.6.5).

6.2.6.   

disconnect from air supply and vent any pressure remaining in the tank by opening drain pan valve (fig 6.2) and/or air valve (fig.6.3.).

note:

  This unit is equipped with a safety valve that has been factory set to cut in at a maximum of 0.45bar (7psi). 

1

2

1

2

3

4

5

   fig.5

   fig.6

sealey group, Kempson Way, suffolk business park, bury st edmunds, suffolk. ip32 7Ar

 01284 757500 

 01284 703534 

 [email protected] 

 www.sealey.co.uk

enVironMent protection

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to 
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely 
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids 
according to local regulations.

note

: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior 

notice. Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call 

our technical team on [email protected] or 01284 757505.

important

: no liability is accepted for incorrect use of this product.

Warranty

: Guarantee is 12 months from purchase date, proof of which is required for any claim.