Sealey AK458DX.V4 Скачать руководство пользователя страница 2

4.  AsseMbly

4.0.1.   

Connect the ball valve (fig.1.1) to the drain basin and tighten it with a suitable wrench.

4.0.2.   

Insert the assembled group into the reservoir tank and tighten the ring sleeve (fig.2.1). Adjust the height and lock in position using the  

 

hand wheel (fig.2.2). 

4.0.3.   

Attach the hose with the ball valve adaptor (fig.3.1) to the base of the reservoir tank.

5.  Air supply

5.1.    

The recommended hook-up is shown in fig.4.

5.2. 

  

Ensure the air valve is in the “Off” position before connecting to  

 

the air supply.

5.3.    

You will require an air pressure of 0.45bar (7psi).

 

‰

  

WArning!

 ensure the air supply is clean and does not exceed  

  pressures specified in these Instructions. Too high an air pressure  

  and/or unclean air will shorten the drainer life due to excessive  

  wear, and may be dangerous, causing damage and/or personal  

 injury.

5.4.    

drain the air tank daily. Water in the air line may damage the drainer.

5.5.    

Clean the air inlet filter screen weekly. 

5.6.    

line pressure should be increased to compensate for unusually  

 

long air hoses (over 8 metres). The minimum hose diameter should  

 

be 10mm I.d. and fittings must have the same inside dimensions.

5.7.    

Keep hose away from heat, oil and sharp edges. Check hoses for wear, and make certain that all connections are secure.

6.  operAtion

 

‰

  

WArning!

 ensure that you read, understand and apply the safety instructions in Section 1.

6.1.    

DrAining oil into the DrAiner

6.1.1.   

To raise or lower the drain pan, slacken off the handwheel (fig.5.1) while supporting the weight of the drain pan, move drain pan to    

 

the correct height and then tighten the hand wheel.

note: 

oil should be removed when hot (70-80°C). Keep hands, face and body protected using suitable personal protective equipment (PPe).

6.1.2.   

drain the oil into the drain pan ensuring that the drain pan valve is open (fig.5.2) and the ball valve tap at the base of the tank is  

 

 

closed (fig.3.1).

6.1.3.   

When draining is complete, lower oil pan before moving drainer.

 

‰

  

WArning!

 ensure the oil level never rises above the maximum level on the indicator located on the side of the tank.

   fig.1

   fig.2

   fig.3

   fig.4

AK458dX.V4 Issue 3 (3) 11/06/19

Original Language Version