Installation of a high power expansion card may require additional cooling to ensure the system can
operate reliably up to 40 degrees Celsius. If a PCIe expansion card dissipates more than 7 Watts inside
the computer an optional PCI slot exhaust fan (PN: PCF-5200-5.7) will likely be necessary to remove the
extra heat.
To install the exhaust fan into the R5200, follow these instructions:
1.
Turn off the system and disconnect from power source.
2.
Remove the three screws from the side of the enclosure and remove the side panel.
3.
Loosen the eight (8) screws located on the top of the system.