Tag-Processing Operations

 

The TagMate USB

®

 is primarily an RFID reader that recognizes TurboTag

®

 T-700 tags 

and ToggleTag™ Mode Selection tags and carries out a pre-programmed sequence of 

communications for reading and/or writing data from/to the tag, then it may process 
the results from a tag into data files and alarm calculations.  This sequence always 

begins with “Tag Search”, in which the device continually scans the environment for 
suitable RFID tags.  Under AC line power, the reader is in Tag Search whenever the 

stand-by LED pattern is active.  In handheld mode, the reader temporarily goes from 
standby into Tag Search for about 10 seconds, allowing users some time to 
reposition the reader after pressing the button (the user does not need to continue 

to press the button while processing a tag).

6

 

 

Once a tag is found, the device attempts to carry out a complete processing 
sequence with it.  While this is occurring, the LED remains blue, indicating that the 

reader is busy.  The process is complete when one of the following results occurs, 
and the LED has returned to the standby state (repetitive blue blink pattern). 

 

1.

 

No Beep

 plus 

three repeats of a red-green alternating LED pattern

This indicates a processing error.  The process should always be retried at 

least once in this case as the failure may have been only a communication 
“glitch”.  If a USB drive is plugged in, a record of each processing error can 

be found in the activity log (file path: TAGMATE\ACTIVITY.LOG), and this 
can help determine the nature of the failure. 

2.

 

Single Long Beep

 plus a 

solid green LED lasting for about a second

 This indicates successful completion of the tag process, and there was no 

alarm resulting from any data analysis. 

a.

 

If the USB drive is connected, and the process leads to a tag data 
file, then a second short beep will sound to indicate successful 

transfer of the data file to the USB drive (file path: 
TAGMATE\DATA\<fname>.TMD) 

3.

 

Two Long Beeps

 plus a 

solid red LED lasting for about two seconds

This indicates successful completion of a tag READ process, accompanied by 

data analysis yielding 

one or more alarms

a.

 

If the USB drive is connected, and the process leads to a tag data 

file, then a second short beep will sound to indicate successful 
transfer of the data file to the USB drive (file path: 
TAGMATE\DATA\<fname>.TMD) 

4.

 

Two Short Beeps

 and the 

LED reverts to the standby state

This indicates that an already-running tag was processed in START mode 

(confirmation of the running status). 

5.

 

Three Short Beeps

 and the 

LED reverts to the standby state

This indicates one of the following configuration-related processes: 

a.

 

A ToggleTag™ Mode Selection tag has updated the operating mode. 

b.

 

A TagMate

®

 Configuration Tag has updated the stored configuration 

on the reader. 

c.

 

A TagMate

®

 Clock Setup Tag has updated the time setting on the 

reader’s internal clock. 

                                                 

6

 

If a bar code scanner is present, barcode scanning is activated first.  When a barcode capture occurs, or 

the button is released, Tag Search begins.  This barcode scan process can be bypassed entirely by 
releasing the button immediately after pressing it. 

TagMateUSB Aug 11, 2009 

 

Page 9 of 20 

Содержание TurboTag USB

Страница 1: ...e 11 Creating TagMate Configuration Tags 12 Creating TagMate Clock Setup Tags 13 Tag READ Operations 14 Read Only vs Read Stop Mode 14 READ Outcomes 14 Tag Data Files 15 Bar Code Scan Data 15 File Man...

Страница 2: ...ause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation CAUTION Any changes or modifications to these devices not ex...

Страница 3: ...of operation of the TagMate USB by making appropriate DIP switch settings see next section The DIP switches are inside the battery compartment of the TagMate USB As shown in the information flow diagr...

Страница 4: ...uration T 700 configure Session Manager read Internet start setup setup configure start read file transfer USB wireless stop stop abc123456 scan scan TagMate USB can be combined with hosted solutions...

Страница 5: ...e section on battery replacement 3 If at power up the reader gives a repetitive red green flash of the LED and an immediate power down with no beep it may need a new firmware file Visit www turbotag d...

Страница 6: ...described later in the section All tag processing operations that can be performed by the TagMate USB from each of these modes are described in later sections The operating mode is controlled by cust...

Страница 7: ...switching perating modes A tool is required to set the DIP switches One simple option is a fter the next power up lection Tags porarily o jumbo paper clip about 5 cm 2 inches long bent as shown here N...

Страница 8: ...ver to hands free operation of the scanner this function always requires pushing the button and is described below Bar Code Scanner Operation The TagMate USB offers bar code scanning as a hardware con...

Страница 9: ...LOG and this can help determine the nature of the failure 2 Single Long Beep plus a solid green LED lasting for about a second This indicates successful completion of the tag process and there was no...

Страница 10: ...ion is optimal for desktop operations and does not obscure the LED The second configuration an end on read mode may be optimal for processing tags that are hard to reach since the reader may be extend...

Страница 11: ...be re started unless it is stopped first See Read Stop below A red green flashing pattern and no beep This indicates a processing error after tag recognition occurred Details about this error may appe...

Страница 12: ...of a TagMate Configuration Tag With this option selected a tag presented to the reader will be specially marked as a TagMate Configuration Tag and the protocol name first 16 characters will automatic...

Страница 13: ...Tags as it will give optimal precision to the clock setting operation The log delay must be zero 2 Once a Clock Setup tag is full it can no longer be used Based on a log interval of 0 1 to 1 0 minute...

Страница 14: ...sis as described below If a USB drive is plugged in a third very short beep will indicate completion of file creation on the USB drive A red green flashing pattern and no beep This indicates a process...

Страница 15: ...scanning is designed to enable the incorporation of identification information associated with monitored goods into the data record from the tag and possibly onto the tag itself see footnote 12 File M...

Страница 16: ...g Tags in Continuous Mode Continuous Mode is a special way of logging data whereby a tag will keep logging after reaching its initial capacity of 702 data points up to a total duration of 16 000 log i...

Страница 17: ...last three characters of the Info Field are therefore lost As described above under Tag START Operations the TagMate USB acquires its configuration parameters and Info field from a TagMate Configurat...

Страница 18: ...tag Tag is re started in continuous mode Tag configured and started in normal mode Full means that 16 000 data logging events have occurred since starting the tag in Continuous Mode it does not mean...

Страница 19: ...batteries Dispose of the expired battery properly and insert the replacement batteries into the holder as shown in the photos below then close the door Note that the polarity of batteries alternates f...

Страница 20: ...Appendix A Processing CFR Tags TagMateUSB Aug 11 2009 Page 20 of 20...

Отзывы: