Tag START Operations

 

 

There are two START operating modes, Start-Only and Start-Config, described 
below.  For details on entering one of these modes, see “Operating Modes of the 

TagMate USB

®

”.  For details about processing tags, see “Tag Processing Operations”. 

 

Start-Only Mode

 

This mode is for processing pre-configured tags, to place them into the “timer-on” 

state for data logging.  Start-Only Mode will work to start any previously-configured 
tag that is not yet running, even if it has stored data from a previous logging 

episode.  The starting time (current time plus log delay, if any) will be written to the 
tag.  Start-Only mode is normally used when a PC is available for pre-configuration 

of tags using TurboTag

®

 

Session Manager

 software. 

 
While a tag is being processed, the LED is solid blue.  The LED and beeper on 

TagMate USB

®

 convey the outcome of a START process as follows:   

 

Single beep accompanied by a green LED light (approx. one second duration, 

then returning to standby).  This indicates a successful processing event.  If 
file creation on START is enabled (DIP switch 3) AND a USB drive is plugged 

in, a second cery short beep will signal completion of file creation on the USB 
drive.  

 

Double short beep, and immediate return to standby.  This indicates that the 
tag is already running and cannot be re-started unless it is stopped first (See 
Read-Stop, below). 

 

A red-green flashing pattern and no beep.  This indicates a processing error 
after tag recognition occurred.  Details about this error may appear in the 

activity log (path: TAGMATE\ACTIVITY.LOG) if a USB drive is plugged in. 

 

No change in LED pattern and no beep.  This indicates that the reader did not 

recognize the tag. This may indicate a damaged tag. 

 

Start-Config Mode 

Tags can be processed using this operating mode as long as they are not running.  
Just prior to starting, tags will be re-configured based on the set of configuration 

values and Info field stored in the TagMate USB

®

.

7

  As with Start-Only mode, the 

current time plus log delay, if any, is also written to the tag, and the possible 

outcomes are as just described. 

 

Note: 

Make sure that any reading of data from a prior logging episode has been completed 
before the Start-Config step, which erases previous data as well as the previous 
configuration. 

Start-Config Mode is useful in packing and shipping operations where it would be 
inconvenient to have quantities of pre-configured tags on hand for shipments that 

require different configurations.   
 

There is no user interface for manual entry of the configuration into the TagMate 
USB

®

.  Instead, one or more special T-700 tags, called a TagMate

®

 Configuration 

                                                 

7

 

For a complete description of tag configuration parameters, see separate instructions for TurboTag

®

 

Session Manager software. 

TagMateUSB Aug 11, 2009 

 

Page 11 of 20 

Содержание TurboTag USB

Страница 1: ...e 11 Creating TagMate Configuration Tags 12 Creating TagMate Clock Setup Tags 13 Tag READ Operations 14 Read Only vs Read Stop Mode 14 READ Outcomes 14 Tag Data Files 15 Bar Code Scan Data 15 File Man...

Страница 2: ...ause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation CAUTION Any changes or modifications to these devices not ex...

Страница 3: ...of operation of the TagMate USB by making appropriate DIP switch settings see next section The DIP switches are inside the battery compartment of the TagMate USB As shown in the information flow diagr...

Страница 4: ...uration T 700 configure Session Manager read Internet start setup setup configure start read file transfer USB wireless stop stop abc123456 scan scan TagMate USB can be combined with hosted solutions...

Страница 5: ...e section on battery replacement 3 If at power up the reader gives a repetitive red green flash of the LED and an immediate power down with no beep it may need a new firmware file Visit www turbotag d...

Страница 6: ...described later in the section All tag processing operations that can be performed by the TagMate USB from each of these modes are described in later sections The operating mode is controlled by cust...

Страница 7: ...switching perating modes A tool is required to set the DIP switches One simple option is a fter the next power up lection Tags porarily o jumbo paper clip about 5 cm 2 inches long bent as shown here N...

Страница 8: ...ver to hands free operation of the scanner this function always requires pushing the button and is described below Bar Code Scanner Operation The TagMate USB offers bar code scanning as a hardware con...

Страница 9: ...LOG and this can help determine the nature of the failure 2 Single Long Beep plus a solid green LED lasting for about a second This indicates successful completion of the tag process and there was no...

Страница 10: ...ion is optimal for desktop operations and does not obscure the LED The second configuration an end on read mode may be optimal for processing tags that are hard to reach since the reader may be extend...

Страница 11: ...be re started unless it is stopped first See Read Stop below A red green flashing pattern and no beep This indicates a processing error after tag recognition occurred Details about this error may appe...

Страница 12: ...of a TagMate Configuration Tag With this option selected a tag presented to the reader will be specially marked as a TagMate Configuration Tag and the protocol name first 16 characters will automatic...

Страница 13: ...Tags as it will give optimal precision to the clock setting operation The log delay must be zero 2 Once a Clock Setup tag is full it can no longer be used Based on a log interval of 0 1 to 1 0 minute...

Страница 14: ...sis as described below If a USB drive is plugged in a third very short beep will indicate completion of file creation on the USB drive A red green flashing pattern and no beep This indicates a process...

Страница 15: ...scanning is designed to enable the incorporation of identification information associated with monitored goods into the data record from the tag and possibly onto the tag itself see footnote 12 File M...

Страница 16: ...g Tags in Continuous Mode Continuous Mode is a special way of logging data whereby a tag will keep logging after reaching its initial capacity of 702 data points up to a total duration of 16 000 log i...

Страница 17: ...last three characters of the Info Field are therefore lost As described above under Tag START Operations the TagMate USB acquires its configuration parameters and Info field from a TagMate Configurat...

Страница 18: ...tag Tag is re started in continuous mode Tag configured and started in normal mode Full means that 16 000 data logging events have occurred since starting the tag in Continuous Mode it does not mean...

Страница 19: ...batteries Dispose of the expired battery properly and insert the replacement batteries into the holder as shown in the photos below then close the door Note that the polarity of batteries alternates f...

Страница 20: ...Appendix A Processing CFR Tags TagMateUSB Aug 11 2009 Page 20 of 20...

Отзывы: