background image

5

SeALAND ToILeT 

BASe ASSeMBLy

BAND CLAMp  

fASTeNeR

SpRING 

CARTRIDGe

WATeR vALve ASSeMBLy

Top vALve CAp

fILTeR SCReeN

WATeR vALve SCReWS

vALve BoDy

ShAfT

peDAL 

CoveR

BAND CLAMp

SeAL

fLuSh BALL

CAM STRAp

DISK

SeALAND ToILeT BoWL, ReAR vIeW 

(Model 712)

vACuuM 

BReAKeR

WATeR vALve hoSe 

CoNNeCTIoN

vACuuM BReAKeR/BoWL CoNNeCTIoN

 TRouBLeShooTING

operation

.   Twist  white  cap  counterclockwise  until  it  stops  (A).  Lift  off 

cap.

2.   Slide switch from OFF to TEST to assure fresh batteries and 

proper  operation.  In TEST  mode,  the  “3/4  FULL”  (left)  and 

“FULL” (right) lights should illuminate. The “LOW BATT” (center) 

light will not illuminate. Slide switch to ON for operation. The 

level indicator can be turned off if the toilet will not be used for 

an extended time.

3.   Replace white cap.

Indicator Lights

When  the  holding  tank  level  reaches  about  3/4  full,  the  yellow  

“3/4 FULL” light illuminates.
When the holding tank is full, the red “FULL” light illuminates. 
The holding tank should be emptied before the toilet is used again. 

If the holding tank fills up and the indicator lights do not glow, the 

probe ends may need to be cleaned. See CLEANING PROBES.

When emptying the tank, the indicator lights may remain lit until 

after the effluent drains from the sensing probes. 

If the lights con

-

tinue to remain lit after a few minutes, the probe ends may need 

to be cleaned. See CLEANING PROBES.

Cleaning probes

.   To remove probes from holding tank, twist off white cap and 

set aside.

2.   Twist and pull black probe body up to remove it from rubber 

grommet. After cleaning probes, be sure to put probe back into 

rubber grommet with the word “TOP” toward back of tank.

Batteries

When the batteries become weak, the red “LOW BATT” light will 

illuminate.  Replace  with AA 

alkaline

  batteries,  making  sure  to 

position new batteries as shown.

 TANK LeveL INDICAToR INSTRuCTIoNS

Содержание 712-TM09

Страница 1: ...Modification of this product can result in property damage WARNING Specifications 2 Installation 2 4 Toilet Operating Instructions 4 Toilet Maintenance 4 Preparing for Summer Use 4 Model Identificati...

Страница 2: ...into a rubber sealing grommet in either corner of the tank no more than 1 2 inch 13mm into tank Be sure to plumb vent pipe correctly to desired outside location Specifications Product Name 712 TM09 S...

Страница 3: ...gap between the bottom of the toilet base and the top of the tank Water line 8 Locate water valve at rear of flush lever 9 Attach water supply line from water system to inlet fitting on back of water...

Страница 4: ...t system by flushing several gallons of fresh water through with one cup of liquid laundry soap 2 Add odor control deodorant in amount specified for your holding tank capacity after cleaning and every...

Страница 5: ...hes about 3 4 full the yellow 3 4 FULL light illuminates When the holding tank is full the red FULL light illuminates The holding tank should be emptied before the toilet is used again If the holding...

Страница 6: ...m breaker c Cracked or defective toilet bowl a Band clamp may be loose a Use SeaLand holding tank deodorant a Tighten band clamp fastener b Clean between flush ball and seal c Replace seal d Replace f...

Страница 7: ...degrees of water hardness SeaLand Environment Friendly brand which is formaldehyde free is similarly effective How Much Deodorant and How to Add It The deodorant is added directly into the toilet bowl...

Страница 8: ...e in material or workmanship All labor and transportation costs or charges incidental to warranty service are to be borne by the purchaser user EXCLUSIONS IN NO EVENT SHALL DOMETIC BE LIABLE FOR INCID...

Отзывы: