Seagull MAP-X2 Скачать руководство пользователя страница 1

 
 
 

 

 

Product: Seagull #MAP-X2 
Released: 2020-04-20 
FW: 2.0 

Seagull

 

#MAP-X2

  

 

User Manual

 

Содержание MAP-X2

Страница 1: ...Product Seagull MAP X2 Released 2020 04 20 FW 2 0 Seagull MAP X2 User Manual ...

Страница 2: ...5 CAMERA ON OFF 5 LOG START END 5 CH1 CH2 COMMAND TABLE 5 CONFIGURING MAP X2 6 GENERAL 6 SETTINGS AND VALUES TABLE 7 FLIGHT CONTROLLER INTEGRATION 8 PIXHAWK 8 DJI A3 8 R C TRANSMITTER INTEGRATION 9 FLIGHT PLANNER SOFTWARE INTEGRATION 9 MISSION PLANNER 9 DJI ASSISTANT 2 10 PORT PIN DEFINITIONS 11 TROUBLESHOOTING 11 TECHNICAL SPECIFICATIONS 11 ...

Страница 3: ...and photos MAP X2 can receive GNSS data via Seagull UAVs GNSS receiver products or other GNSS receivers capable of providing necessary messages that are recognized by MAP X2 for data logging NOTE MAP X2 can also log GNSS data without a SYNC event feedback MAP X2 features High data rate sampling 4Hz MB 5Hz RTK 10Hz RAW 10Hz GNSS Various trigger modes SST ACT PWM BUTTON TIMELAPSE Trigger and Log wit...

Страница 4: ...n the MAP series cable finder PWM mode is meant to trigger cameras that use PWM signal as a command for triggering such as the FLIR VUE Pro thermal camera ACT PWM Autofocus Custom Trigger Pulse Width Modulation When operating in this mode it enables both modes ACT and PWM to trigger either on HIGH or LOW end of signal for CH1 input ACT mode is meant for use to trigger cameras that are connected to...

Страница 5: ...ly available with camera cables listed as Sony S2 w on off for Sony MULTI enabled cameras LOG START END This command must be executed in order for X2 to generate log files X2 will only start log generation once the command LOG START END has been executed The LOG START END can be executed via the following options Sending 1800 μS signal to MAP X2 via CH2 Clicking the LOG button on MAP X2 Setting Lo...

Страница 6: ...MAP X2 GENERAL MAP X2 can be configured by Seagull MAP X2 Config exe that can be downloaded via the following link https www seagulluav com seagull map x2 support Please use the C USB Port on MAP X2 to configure Seagull MAP X2 Configurator example photo ...

Страница 7: ... executed and PWM duration ends PWM Neutral Value Value in μS 550 2400 μS 1500 NEUTRAL value for your PWM camera meaning that when set in this value it will not execute anything and wait for trigger value to occur again LOGGING SETTINGS Logging Activation MANUAL AUTO n a MANUAL Can be enabled to AUTO logging start and end When there is a signal present on CH1 which is above 999 μS and below 2001 μ...

Страница 8: ...hawk 1 rails is 5 7V follow documentation of the ArduPilot controller that you have Its recommended to use 5V UBEC to provide power to the rails DJI A3 Connect the CHANNEL that you wish to control from MAP X2 to the F port that you wish to use DJI A3 can t provide power to the MAP X2 through its rails therefore connect only BLACK and WHITE signal to the F port and power MAP X2 via UBEC or such tha...

Страница 9: ...the do_digicam_control command When a channel is setup via Camera Gimbal menu that channel is occupied by Pixhawk and you will not be able to pass manual trigger commands via R C transmitter If you wish to control the channel manually you will need to setup the RC channel as pass through in the Mission Planner 1 Click on INITIAL SETUP OPTIONAL HARDWARE CAMERA GIMBAL 2 SHUTTER in the drop down list...

Страница 10: ...r mode CH1 CH2 COMMAND TABLE 3 SHUTTER DEFAULT PWM Set the value 1500 NEUTRAL STATE 4 SHUTTER PWM FREQUENCY Select 50Hz option 5 SHUTTER PWM ACTIVE Set the value to 100 It is also possible to map a switch to have manual triggering option this can be done when selecting the port to operate as Sx and inputting the value in LOW and HIGH range To achieve a NEUTRAL value for the switch it is calculated...

Страница 11: ...TROUBLESHOOTING To determine what Seagull MAP X2 is currently doing simply read the output of the X STATE and SD CARD LEDs then match it with the Action in the table below TECHNICAL SPECIFICATIONS Supply voltage 3 9 12V 5v recommended do NOT exceed 12V Current draw Min 17mA Average 43mA Max 55mA Input signal 3 3V standard R C PWM between 1000 2000μS Dimensions 48mm x 40mm x 11mm Weight 20g without...

Отзывы: