background image

Lyrion Series IDE Product Manual, Rev. B

27

4.2.1

Identify Device command

The Identify Device command (command code EC

H

) transfers information about the drive to the host following 

power up. The data is organized as a single 512-byte (256 word) block of data, whose contents are as shown 
in the following table.

Word

 

ATA specification

 

Value

 

0 General 

configuration 

information 

bit-significant 

information 

 Bit 15: 0 = ATA device  
 Bit 7:   1 = removable media 
 Bit 6:   1 = non-removable/fixed device  

0040h 

10–19 

Serial number: (20 ASCII characters) 

Serial number 

23–26  Firmware revision (8 ASCII character string) 

Firmware revision 

27–46  Drive model number:  

(40 ASCII characters, padded with blanks to end of string) 

Model number 

47 

Bits 7-0: Maximum number of sectors transferred per interrupt on 
               Read Multiple/ Write Multiple commands 

8010h 

49 Capabilities 

 

Bit 13: 1= Standby timer values specified in ATA-7 are supported 

Bit 11: 1= IORDY supported 

Bit 10: 0= IORDY may not be disabled 

Bit 9  : 1= LBA supported 

Bit 8  : 1= DMA supported 

2B00h 

53 

Bit 2: 1= the fields reported in word 88 are valid 

Bit 1: 1= the fields reported in words (70:64) are valid 

0007h 

59 

Bit 8: 1=  Multiple sector setting is valid 

Bits 7-0:  Current setting for number of sectors transferred during a
                Read/Write Multiple command  

0110h 

60–61  Total number of user-addressable LBA sectors available 

37E3E40h (30GB) 
6FC7C80h (60GB) 

63 

Bit 10: 1= Multiword DMA mode 2 is selected 

           0= Multiword DMA mode 2 is not selected 

Bit 9:   1= Multiword DMA mode 1 is selected 

           0= Multiword DMA mode 1 is not selected 

Bit 8:   1= Multiword DMA mode 0 is selected 

           0= Multiword DMA mode 0 is not selected 

Bit 2:   1= Multiword DMA mode 2 and below are supported 

Bit 1:   1= Multiword DMA mode 1 and below are supported  

Bit 0:   1= Multiword DMA mode 0 is supported 

xxx7h 

64 

Bits 7-0: PIO modes supported 

0003h 

65 

Minimum Multiword DMA transfer cycle time per word 
Bits 15-0: Cycle time in nanoseconds 

0078h 

66 

Recommended Multiword DMA transfer cycle time 
Bits 15-0: Cycle time in nanoseconds 

0078h 

67 

Minimum PIO transfer cycle time without flow control 
Bits 15-0: Cycle time in nanoseconds 

0078h 

68 

Minimum PIO transfer cycle time with IORDY flow control 
Bits 15-0: Cycle time in nanoseconds 

0078h 

Содержание ST730212DEG

Страница 1: ...Product Manual Lyrion Series IDE 100462437 Rev B May 2007 ST760211DE ST730212DE ...

Страница 2: ...ate Technology LLC or one of its affiliated companies in the United States and or other countries All other trademarks or registered trademarks are the property of their respective owners One gigabyte or GB equals one billion bytes when referring to hard drive capacity Accessible capacity may vary depending on operating environment and formatting Seagate reserves the right to change with out notic...

Страница 3: ... 11 2 8 6 Vibration 11 2 8 7 Corrosive environment 13 2 9 Acoustics 14 2 10 Electromagnetic immunity 14 2 11 Reliability 14 2 12 Agency certification 15 2 12 1 Safety certification 15 2 12 2 Electromagnetic compatibility 15 2 12 3 European Union Restriction of Hazardous Substances RoHS Directive 15 2 12 4 China Restriction of Hazardous Substances RoHS Directive 16 2 12 5 FCC verification 16 3 0 Co...

Страница 4: ...ii Lyrion Series IDE Product Manual Rev B ...

Страница 5: ...Figure 3 Location where tri axial accelerometer will be placed on Lyrion Series drives 11 Figure 4 Drive axis definition for Lyrion Series drives 11 Figure 5 Lyrion Series breather hole location 19 Figure 6 Lyrion Series proper handling example 19 Figure 7 Lyrion Series mechanical dimensions top side and end view 21 Figure 8 Lyrion Series Area for Protective Mounting 22 ...

Страница 6: ...iv Lyrion Series IDE Product Manual Rev B ...

Страница 7: ...600 RPM spindle speed and a 2 Mbyte buffer combined for superior read write performance Quiet operation Fluid Dynamic Bearing FDB motor Perpendicular recording heads and EPRML technology which provide the drives with increased areal density State of the art cache and on the fly error correction algorithms 1500 G nonoperating shock and 500 G operating shock SeaTools diagnostic software performs a d...

Страница 8: ...ntial damages including but not limited to loss of use data or profits procurement of substitute goods or services or business interruptions however caused and on any theory of liability whether in contract strict liability or tort including negligence or otherwise arising in any way from the use of this kit even if advised of the possibility of such damage 1 2 Drive care Do not use the Lyrion Ser...

Страница 9: ...ack density TPI tracks inch average 165 000 Areal density Gbits inch2 average 169 Spindle speed RPM 3 600 Internal data transfer rate OD Mbits sec max 350 Sustained data transfer rate OD Mbytes sec 24 5 I O data transfer rate Mbytes sec max 66 7 UDMA 4 ATA data transfer modes supported PIO modes 0 4 Multiword DMA modes 0 2 Ultra DMA modes 0 4 Height 5 0 0 15 mm 0 1968 0 006 inches Width 54 0 0 3 m...

Страница 10: ...mean sea level max 60 98 m to 12 192 m 200 ft to 40 000 ft Shock operating Gs max at 2 msec 500 Shock nonoperating Gs max at 1 msec 1500 Vibration operating max displacement may apply below 10 hz 1 0 Gs 0 to peak 10 500 Hz 2 oct min sweep rate Vibration nonoperating max displacement may apply below 22 hz 5 0 Gs 0 to peak 10 500 Hz 0 5 oct min sweep rate Idle sound power bels typical 1 6 Operationa...

Страница 11: ...165 000 Areal density Gbits inch2 average 169 Spindle speed RPM 0 2 3 600 Internal data transfer rate OD Mbits sec max 350 Sustained data transfer rate OD Mbytes sec max 24 5 I O data transfer rate Mbytes sec max 66 7 UDMA 4 Cache buffer Mbytes 2 Height mm inches 5 0 0 15 0 1968 0 006 Width mm inches 54 0 0 3 2 1260 0 0118 Length mm inches 71 0 0 3 2 7953 0 0118 Typical weight grams pounds 48 0 ty...

Страница 12: ... and does not execute a read or write operation Servo electronics are active Seek power is measured based on three random seek operations every 100 msecs Read write mode Read write power is measured with the heads on track while the head is reading writing from to disc It is performed with 100 percent duty cycle of read write operation Performance Idle mode During Performance Idle mode the heads a...

Страница 13: ... in 10 msec window 2 7 1 1 Typical current profile Figure 2 Typical 3 3V startup and operation current profile Table 2 DC power Power Consumption at 3 3V Average W Startup max 1 15 Read 1 0 Write 0 9 Performance idle typical 0 5 Low power idle typical 0 3 Standby Sleep typical 0 08 ...

Страница 14: ...3 3 volt line Using 3 3 volt power the drive is expected to operate with a maximum of 70 mV peak to peak square wave injected noise at up to 20 MHz Note Equivalent resistance is calculated by dividing the nominal voltage by the typical RMS read write current 2 7 3 Voltage tolerance and Maximum current Voltage tolerance including noise 3 3V 5 Maximum Current peak to peak 500mA ...

Страница 15: ...Performance Idle mode when the Advanced Power Management Level is set between 80h and FDh and the Idle timer reaches 15 seconds Disc is spinning and heads are parked and drive accepts all commands and returns to Active mode any time disc access is necessary Standby Sleep mode The drive enters Standby mode when the host sends a Standby Immediate command In Standby mode the drive buffer is disabled ...

Страница 16: ...3 1 Relative humidity 2 8 3 2 Wet bulb temperature 1 Operating Wet bulb temperature is calculated by the operating Temperature and the Relative Humidity levels 2 Nonoperating Wet bulb temperature is calculated by the nonoperating Temperature and the Relative Humidity levels 2 8 4 Altitude Operating 0 to 60 C 32 to 140 F 70 C max case temperature Nonoperating 40 to 70 C 40 to 158 F Operating 20 C p...

Страница 17: ...ve is subjected to 10 shocks for each direction During the shocks there must be a minimum delay of 3 seconds between shock pulses Soft errors and automatic retries are allowed during the test No data loss or permanent damage occurs during a half sine shock pulse of 500 G 2 msec 2 8 5 2 Nonoperating shock The nonoperating shock level that the drive can experience without incurring any physical dama...

Страница 18: ...thout a hard error while being subjected to the following vibration levels 2 8 6 3 Nonoperating sweep sine vibration The following table lists the maximum nonoperating sweep sine vibration levels that the drive may experience while meeting the performance standards specified It consists of a forward and backward sweep from 5 Hz to 500 Hz to 5 Hz The drive does not incur any physical damage when su...

Страница 19: ...to uncontrolled chemical pollutants and corro sive chemicals as electronic drive component reliability can be affected by the installation environment The sil ver copper nickel and gold films used in Seagate products are especially sensitive to the presence of sulfide chloride and nitrate contaminants Sulfur is found to be the most damaging In addition electronic components should never be exposed...

Страница 20: ...t system the drive operates without errors or degradation in performance when subjected to the radio frequency RF environments defined in the following table 2 11 Reliability Table 6 Drive level acoustics Acoustic mode Idle Operational 1 6 bels typ 2 2 bels typ Table 7 Electromagnetic immunity Test Description Performance level Reference standard Radiated RF immunity 80 to 1 000 MHz 3 V m 80 AM wi...

Страница 21: ... these drives have the Korea Ministry of Information and Communication MIC logo they comply with para graph 1 of Article 11 of the Electromagnetic Compatibility control Regulation and meet the Electromagnetic Compatibility EMC Framework requirements of the Radio Research Laboratory RRL Ministry of Information and Communication Republic of Korea These drives have been tested and comply with the Ele...

Страница 22: ...ove to ensure that the total assembly enclosure disc drive motherboard power supply etc does comply with the limits for a Class B computing device pursuant to Subpart J Part 15 of the FCC rules Operation with noncertified assemblies is likely to result in interference to radio and television reception Radio and television interference This equipment generates and uses radio frequency energy and if...

Страница 23: ...itional sug gestions You may find helpful the following booklet prepared by the Federal Communications Commission How to Identify and Resolve Radio Television Interference Problems This booklet is available from the Super intendent of Documents U S Government Printing Office Washington DC 20402 Refer to publication num ber 004 000 00345 4 ...

Страница 24: ...18 Lyrion Series IDE Product Manual Rev B ...

Страница 25: ...breather hole location Keep the drive in the electrostatic discharge ESD bag until you are ready for installation to limit the drive s exposure to ESD Before handling the drives put on a grounded wrist strap or ground yourself frequently by touching the metal chassis of a computer that is plugged into a grounded outlet Wear a grounded wrist strap throughout the entire installation procedure Handle...

Страница 26: ...ve in the protective casing when not in use Turn the power off before installing or removing the drive Do not apply any force to the drive during handling or installation Do not touch the connector pins or the printed circuit board Do not drop the drive Do not expose the drive to wet conditions Do not place the drive near a strong magnetic field Do not expose the drive to extreme temperatures The ...

Страница 27: ... Follow instructions for the installation of data storage devices provided with your device s user manual Do not obstruct the breather hole on the drive see Figure 5 Handle the drive only by its edges or frame or designated finger grip region during mounting see Figure 6 Figure 7 Lyrion Series mechanical dimensions top side and end view X Temperature Measurement Position ...

Страница 28: ...can be operated in any orientation but horizontal or vertical orientation is preferred Allow a minimum clearance of 0 012 inches 0 30 mm around the entire perimeter of the drive for cooling with the exception of the mounting edges for better airflow In case the system design warrants bending of the FPC to the hard disc drive care should be taken to maximize the radius Mounting materials are availa...

Страница 29: ...nector Table 8 40 way ZIF IDE interface connector signals Pin number Signal Name Description 1 Reserved 2 Reserved 3 RESET Hard Reset 4 GROUND Ground 5 DD07 Data bus bit 7 6 DD08 Data bus bit 8 7 DD06 Data bus bit 6 8 DD09 Data bus bit 9 9 DD05 Data bus bit 5 10 DD10 Data bus bit 10 11 DD04 Data bus bit 4 12 DD11 Data bus bit 11 13 DD03 Data bus bit 3 14 DD12 Data bus bit 12 15 DD02 Data bus bit 2...

Страница 30: ...UND Ground 27 IORDY DDMARDY DSTROBE I O Channel Ready during register access Flow control during Ultra DMA data out burst Data in strobe signal for Ultra DMA data in burst 28 GROUND Ground 29 DMACK DMA Acknowledge 30 INTRQ Interrupt Request 31 DA01 Address bus bit 1 32 PDIAG 33 DA00 Address bus bit 0 34 DA02 Address bus bit 2 35 CS0 Chip Select 0 36 CS1 Chip Select 1 37 DASP Used to drive external...

Страница 31: ... 35h DMA data out Set Max Address Ext 37h Non data Write Multiple Ext 39h PIO data out Read Verify Sector s 40h Non data Read Verify Sector s Ext 42h Non data Execute Drive Diagnostics 90h Non data Download Microcode 92h PIO data out SMART B0h SMART Disable Operations Non data SMART Enable Disable Autosave Non data SMART Enable Operations Non data SMART Execute Off Line Immediate Non data SMART Re...

Страница 32: ...ta Sleep E6h Non data Flush Cache E7h Non data Flush Cache Ext EAh Non data Write Buffer E8h PIO data out Identify Device ECh PIO data in Set Features EFh Non data Security Set Password F1h PIO data out Security Unlock F2h PIO data out Security Erase Prepare F3h Non data Security Erase Unit F4h PIO data out Security Freeze Lock F5h Non data Security Disable Password F6h PIO data out Read Native Ma...

Страница 33: ...upported 2B00h 53 Bit 2 1 the fields reported in word 88 are valid Bit 1 1 the fields reported in words 70 64 are valid 0007h 59 Bit 8 1 Multiple sector setting is valid Bits 7 0 Current setting for number of sectors transferred during a Read Write Multiple command 0110h 60 61 Total number of user addressable LBA sectors available 37E3E40h 30GB 6FC7C80h 60GB 63 Bit 10 1 Multiword DMA mode 2 is sel...

Страница 34: ...SMART self test supported Bit 0 1 SMART error logging supported 6063h 85 Command sets referred in word 82 enabled xxxxh 86 Command sets referred in word 83 enabled xxxxh 87 Command set feature default Bit 5 1 General Purpose Logging feature supported Bit 1 1 SMART self test supported Bit 0 1 SMART error logging supported 6063h 88 Bit 12 1 Ultra DMA mode 4 is selected 0 Ultra DMA mode 4 is not sele...

Страница 35: ... 0102 189 0000 232 0000 18 xxxx 61 06FC 104 0000 147 0000 190 0000 233 0000 19 xxxx 62 0000 105 0000 148 0078 191 0000 234 0000 20 0000 63 0407 106 0000 149 0618 192 0000 235 0000 21 0000 64 0003 107 0000 150 0000 193 0000 236 0000 22 0004 65 0078 108 0000 151 0000 194 0000 237 0000 23 xxxx 66 0078 109 0000 152 0000 195 0000 238 0000 24 xxxx 67 0078 110 0000 153 1212 196 0000 239 0000 25 2020 68 0...

Страница 36: ...abled Hardware Reset Current setting Software Reset Current setting Software Reset Current setting Feature Description 02h Enable Write Cache 03h Set DMA and PIO transfer modes based on the value in the Sector Count register Sector Count register values 08h Set PIO Transfer Mode 0 09h Set PIO Transfer Mode 1 0Ah Set PIO Transfer Mode 2 0Bh Set PIO Transfer Mode 3 0Ch Set PIO Transfer Mode 4 20h Se...

Страница 37: ...rdware Reset and Software Reset Table 11 Register default values Power On Reset Hardware Reset Software Reset Error register 01h 01h 01h Sector Count register 01h 01h 01h Sector Number register 01h 01h 01h Cylinder Lo register 00h 00h 00h Cylinder Hi register 00h 00h 00h Device Head register 00h 00h 00h Status register 50h 50h 50h Alt Status register 50h 50h 50h ...

Страница 38: ...32 Lyrion Series IDE Product Manual Rev B ...

Страница 39: ...s with product information program benefits and sales tools You may register for customized communications that are not available on the web These communications contain product launch EOL pricing promotions and other channel related information To learn more about the benefits or to register go to spp seagate com any time from anywhere in the world Seagate Service Centers Presales Support Our Pre...

Страница 40: ...ailable on a global basis for the return of defective products Contact your customer support representative for the location nearest you USA Canada Latin America support services For an extensive list of telephone numbers to technical support presales and warranty service in USA Canada Latin America including business hours go to the Contact Us page on www seagate com Global Customer Support Presa...

Страница 41: ...on feedback survey We are interested in your comments and suggestions regarding this publication Please take a few minutes to participate in our survey at the following URL http survey seagate com survey techpubs nsf Thank you for your time and comments ...

Страница 42: ...36 Lyrion Series IDE Product Manual Rev B ...

Страница 43: ...ectromagnetic Compatibility Directive 15 electromagnetic immunity 14 EMC compliance 15 enclosures 16 environmental specifications 10 EPRML 1 error correction algorithms 1 errors 14 EU RoHS directive 15 European Union 15 F FCC verification 16 Features register 30 formatted capacity 4 frequency 14 G guaranteed sectors 4 H handling 19 heads 1 height 5 humidity 10 I I O data transfer rate 5 Identify D...

Страница 44: ...equency RF 14 read errors 14 read write mode 6 recording and interface technology 5 recording density 5 recording heads 1 recording method 5 register 30 register default values 31 relative humidity 10 reliability 14 resistance 8 RF 14 RoHS 15 16 S safety certification 15 SeaTools 1 sectors 4 seek mode 6 Set Features command 30 shock 11 signals 23 sleep mode 6 sound 14 specifications 3 spindle spee...

Страница 45: ......

Страница 46: ...Seagate Technology LLC 920 Disc Drive Scotts Valley California 95066 4544 USA Publication Number 100462437 Rev B Printed in U S A ...

Отзывы: