background image

are not crimped or damaged in any way. Keeping extra cables
on hand for troubleshooting saves time and frustration.

For each ribbon cable, verify that pin 1 of the cable is matched
to pin 1 of the connector. Pin 1 is usually denoted by a stripe
on the side of the ribbon cable.

Caution. Do not randomly reverse-plug the cables. This can

damage some systems. 

When  connecting  the  diskette  drive,  make  sure  you  use  a
control cable for a diskette drive and not a hard drive. Unlike
the hard drive cable, the diskette drive control cable has seven
lines split and twisted.

Check the BIOS memory address. Make sure the address
you  typed  during  DEBUG  agrees  with  the  address  you  se-
lected with the host adapter BIOS address selection jumper. 

Assuming you have configured the host adapter correctly and
a memory conflict exists, the problem might be that the host
adapter is trying to use the same BIOS memory address as
another peripheral on your system. The easiest solution is to
try all possible BIOS addresses. 

If the memory conflict persists, isolate the conflict by discon-
necting  all  other  peripherals  (except  the  video  card)  and
installing the drive and the host adapter separately from the
other components. Then, install the other peripherals one at
a time until the conflict resurfaces.

Once you have isolated the source of the address conflict, you
can resolve the conflict by either changing the BIOS address
of  the  peripheral  that  appears  to  cause  the  conflict,  or  by
changing the BIOS address of the host adapter. 

Check for viruses.

 Before you load new software, scan the

diskette for viruses.

ST3390N, ST3655N Installation Guide, Rev. A

13

Содержание ST3390N

Страница 1: ...ST3390N ST3655N SCSI Interface Drive Installation Guide...

Страница 2: ...trademarks of their owners Seagate reserves the right to change without notice product offerings or specifications No part of this publication may be reproduced in any form without written permission...

Страница 3: ...eted areas Drive handling The drive is extremely fragile handle it with care Do not attach labels to any part of the drive Inspection Once you are familiar with the handling precautions listed above i...

Страница 4: ...an der Unterseite nicht mehr als 5 08 mm betragen 3 Als Versorgungsspannugen werden ben tigt 5V 5 0 5A 12V 5 0 5A 1 9A fur ca 30 Sek fur 10 4 Die Versorgungsspannung mu SELV entsprechen 5 Alle Arbeite...

Страница 5: ...and 4 of the terminator power source jumper block does not disconnect the terminating resistors from the circuit If your application requires no terminatingresistors you must unplugthem from the drive...

Страница 6: ...ed in the following table Fast SCSI SCSI Termination Active Active or passive Terminator specification 110 ohms 110 ohms or 220 330 ohms Install active passive termination jumpers Pins 1 and 2 Pins 1...

Страница 7: ...e maximum cable length is 6 feet 1 8 meters Spindle synchronization pins are located on two separate jumper blocks the options jumper block and the user con figuration jumper block Use either jumper b...

Страница 8: ...ound Signal 6 5 J9 Active passive termination jumper block Circuit board 2 85V to 110 ohms 3 4 1 2 5 6 LSB Terminating resistor packs pin 1 Circuit board Power and ground to 220 330 ohms J6 Terminator...

Страница 9: ...ground Remote LED Remote LED Reserved Do not use Pin 17 18 15 16 19 20 J12 Options jumper block 7 8 5 6 3 4 1 2 Circuit board Pin Function 1 Ground 2 Parity enable 3 Ground 4 Remote start enable 5 Cl...

Страница 10: ...drive You can mount the drive in any orientation Follow the guidelines below for either bottom mounting or side mounting Figure 3 shows the recommended mounting orientations and the optimum placement...

Страница 11: ...Interface connector Power connector Figure 3 Recommended mounting orientations ST3390N ST3655N Installation Guide Rev A 9...

Страница 12: ...set to zero or the no hard drive installed option Physical geometry for non DOS operating systems When installing the drive in non DOS operating systems use the following information to configure you...

Страница 13: ...using you need to prepare the drive by writing partitioninginformation on it After you have configured the drive and defined it in the CMOS boot the system from the diskette drive with a bootable DOS...

Страница 14: ...cards Verify compatibility Reread the documentation for the host adapter and the drive to confirm that these components are appropriately matched to each other and to your computer Verify your configu...

Страница 15: ...ction jumper Assuming you have configured the host adapter correctly and a memory conflict exists the problem might be that the host adapter is trying to use the same BIOS memory address as another pe...

Страница 16: ...ngs and the active passive termination jumper settings described on pages 3 and 4 respectively Check the power supply specifications Reboot and make sure the drive spins up It may be difficult to hear...

Страница 17: ...reboot the host adapter may be incompatible or defective See your dealer The system hangs in FDISK or fails to create or save the partition record Check all cables The DOS utilities diskette may be c...

Страница 18: ...ays consult your system dealer first for technical support Dealers are generally more familiar with unique system configu rations Technical support is available for all Seagate products by calling the...

Страница 19: ...e Request a return phone call from the technical support staff SeaBoard is available 24 hours daily It supports communica tions up to 9600 baud Set your communications software to eightdata bits no pa...

Страница 20: ...Seagate Technology Inc 920 Disc Drive Scotts Valley CA 95066 USA Publication Number 36235 001 Rev A Printed in USA...

Отзывы: