ST12450W/WD Product Manual, Rev. A
25
Air-flow cooling
ST12450WD
differential
MTBF
500k hours
Card
Component
Reference
case temperature (°C)
RYGX
Transmitter
U5
64
RYGX
Detector
U58
73
RYGX
VIC 2
U20
59
RYGX
Flash PROM
U53
59
RYGX
Transceiver
U7
59
HDA housing
Figure 9
The air-flow pattern with which the temperature guidelines above were
generated is shown in Figure 6. Local average air velocities were 0.61
msec (120 lfpm) and inlet air temperature to the drive was 30°C (86°F).
The maximum allowable HDA case temperature is 60°C.
U20
U53
U7
U58
U5
Figure 8. RYGX temperature measurement locations
.50
1.00
Figure 9. Temperature measurement location
Measure the HDA housing temperature at the location specified in Figure 9.