background image

Seagate Enterprise Capacity 3.5 HDD v7 SAS Product Manual, Rev. C

  25

  

6.0

Physical/electrical specifications

This section provides information relating to the physical and electrical characteristics of the drive.

6.1

PowerChoice

TM

 power management

Drives using the load/unload architecture provide programmable power management to tailor systems for performance and greater energy

 

efficiency.

The table below lists the supported PowerChoice modes. The further down the user goes in the table, the more power savings the user gets. For 
example, Idle_B mode results in greater power savings than Idle_A mode. Standby_Z mode results in the greatest power savings. 

PowerChoice modes

PowerChoice

TM 

can be invoked using one of these two methods:

• Power Condition mode page method—Enable and initialize the idle condition timers and/or the standby condition timers. The timer values are

 

based on the values set in the Power Condition mode page. 

• START STOP UNIT command method—Use the START STOP UNIT command (OPERATION CODE 1Bh). This allows the host to directly transition the

 

drive to any supported PowerChoice mode. 

If both the Power Condition mode page and START STOP UNIT command methods are used, the START STOP UNIT command request takes 
precedence over the Power Condition mode page power control and may disable the idle condition and standby condition timers. The REQUEST

 

SENSE command reports the current PowerChoice state if active and also the method by which the drive entered the PowerChoice state.

When the drive receives a command, all power condition timers are suspended if they were enabled via the Power Condition mode page. Once all 
outstanding commands are processed, the power condition timers are reinitialized to the values defined in the Power Condition mode page

6.1.1

PowerChoice reporting methods

PowerChoice

TM

 provides these reporting methods for tracking purposes:

Request Sense command reports

• Current power condition
• Method of entry

.

Mode Sense command reports (mode page 0x1A)

• Idle conditions enabled / disabled
• Idle condition timer values (100ms increments) (default, saved, current, changeable)

Power Condition Vital Product Data (VPD) Page (VPD page 0x8A)

• Supported power conditions
• Typical recovery time from power conditions (1ms increments)

Start/Stop Cycle Counter Log Page reports (log page 0x0E)

• Specified and accumulated Start/Stops and Load/Unload cycles

Power Condition Transitions Log Page reports (log page 0x1A, subpage 0x00)

• Accumulated transitions to Active, Idle_A, Idle_B, Idle_C, Standby_Y, Standby_Z

Mode

Description

Idle_A

Reduced electronics

Idle_B

Heads unloaded. Disks spinning at full RPM

Idle_C

Heads unloaded. Disks spinning at reduced RPM

Standby_Y

Heads unloaded. Disks spinning at reduced RPM.

 

Recovery requires the NOTIFY (Enable Spinup) command.

Standby_Z

Heads unloaded. Motor stopped (disks not spinning)

 

Recovery requires the NOTIFY (Enable Spinup) command.

Note

 Processing the Request Sense command does not impact the drive’s power save state.

Содержание ST12000NM0027

Страница 1: ...ST12000NM0027 Self Encrypting Drive SED model ST12000NM0037 Enterprise Capacity 3 5 HDD v7 SAS Product Manual Default configuration is 512E See Section 4 1 2 to Fast Format to 4KN in seconds 100815204...

Страница 2: ...d of measurement and report a lower capacity In addition some of the listed capacity is used for formatting and other functions and thus will not be available for data storage Actual quantities will v...

Страница 3: ...3 Environmental protection 10 2 3 1 European Union Restriction of Hazardous Substance Law 10 2 3 2 China Requirements China RoHS 2 11 2 3 3 Taiwan Requirements Taiwan RoHS 11 2 4 Reference documents...

Страница 4: ...Test DST 22 5 2 6 Product warranty 24 6 0 Physical electrical specifications 25 6 1 PowerChoiceTM power management 25 6 1 1 PowerChoice reporting methods 25 6 2 Power Balance 26 6 3 AC power requireme...

Страница 5: ...8 Power requirements 36 7 9 Supported commands 36 7 10 Sanitize CRYPTOGRAPHIC ERASE 36 7 11 RevertSP 36 8 0 Defect and error management 37 8 1 Drive internal defects errors 37 8 2 Drive error recovery...

Страница 6: ...iry data 47 10 3 2 Mode Sense data 48 10 4 Miscellaneous operating features and conditions 50 10 4 1 SAS physical interface 50 10 4 2 Physical characteristics 53 10 4 3 Connector requirements 53 10 4...

Страница 7: ...contacts For information regarding Warranty Support visit http www seagate com support warranty and replacements For information regarding data recovery services visit http www seagate com services s...

Страница 8: ...ill use one of the models listed or future generation products and need further assistance please contact the Field Applications Engineer FAE or our global support services group as shown in See Seaga...

Страница 9: ...llowing information provides an overview of requirements that may be applicable to the drive 2 2 1 Safety certification These products are certified to meet the requirements of UL cUL 60950 1 EN 60950...

Страница 10: ...Canada ICES 003 If this model has the ICES 003 2016 marking it complies with requirements of ICES tested per ANSI C63 4 2014 2 2 6 South Korean KC Certification Mark The South Korean KC Certification...

Страница 11: ...chnician for additional suggestions Users may find helpful the following booklet prepared by the Federal Communications Commission How to Identify and Resolve Radio Television Interference Problems Th...

Страница 12: ...n 5 of CNS 15663 effective January 1 2018 This product is Taiwan RoHS compliant The following table meets the Section 5 Marking of presence requirements Table 1 China Hazardous Substances Part Name Ha...

Страница 13: ...4 INCITS 536 Zone Block Commands ZBC INCITS 534 Serial Attached SCSI SAS 4 INCITS 506 SCSI Block Commands 4 SBC 4 INCITS 502 SCSI Primary Commands 5 SPC 5 ANSI Small Computer System Interface SCSI Do...

Страница 14: ...rate The Self Encrypting Drive models indicated on the cover of this product manual have provisions for Security of Data at Rest based on the standards defined by the Trusted Computing Group see www...

Страница 15: ...ical block User selectable logical block sizes for 512E 512 520 524 or 528 bytes per logical block Vertical horizontal or top down mounting Seagate Enterprise Capacity 3 5 HDD v7 SAS Self Encrypting D...

Страница 16: ...zero and less than the maximum number of LBAs in the Number of Blocks field changes the total drive capacity to the value in the Number of Blocks field A value greater than the maximum number of LBAs...

Страница 17: ...creased by 30 minutes 4 1 2 Fast Format Drive sector size transition Single code to support sector sizes from 512E T10 fast format conversion between 512E configurations in the field Possible only if...

Страница 18: ...of DC power SCSI stop time is 23 seconds There is no power control switch on the drive 4 3 Prefetch multi segmented cache control The drive provides a prefetch read look ahead and multi segmented cac...

Страница 19: ...he data to be written to the medium is stored while the drive performs the Write command If read caching is enabled RCD 0 then data written to the medium is retained in the cache to be made available...

Страница 20: ...are only detected during read operations but not caused by the read If an unrecoverable data error is detected a MEDIUM ERROR 03h in the Sense Key will be reported Multiple unrecoverable data errors r...

Страница 21: ...o communicate on its interfaces When the self test completes successfully the drive initiates a Link Reset starting with OOB An attached device should respond to the link reset If the link reset attem...

Страница 22: ...nal Exceptions Control mode page 1Ch An example if the MRIE is set to one the firmware will issue to the host an 01 5D00 sense code The FRU field contains the type of predictive failure that occurred...

Страница 23: ...e are two test coverage options implemented in DST 1 Extended test 2 Short test The most thorough option is the extended test that performs various tests on the drive and scans every logical block add...

Страница 24: ...hort test or 010b for the extended test in bytes 1 bits 5 6 and 7 5 2 5 2 3 Short and extended tests DST has two testing options 1 short 2 extended These testing options are described in the following...

Страница 25: ...agnostic Users can abort a DST executing in background mode by using the abort code in the DST Function Code field This will cause a 01 self test aborted by the application client code to appear in th...

Страница 26: ...orts the current PowerChoice state if active and also the method by which the drive entered the PowerChoice state When the drive receives a command all power condition timers are suspended if they wer...

Страница 27: ...additional drain on the 12V supply Table 3 12TB drive DC power requirements Notes 12 0Gb mode Amps Amps Watts Voltage 5V 12V 2 Regulation 5 5 10 2 Avg idle current DCX 1 6 0 309 0 292 5 05 Advanced i...

Страница 28: ...band from three quarters to maximum track General DC power requirement notes 1 Minimum current loading for each supply voltage is not less than 1 7 of the maximum operating current shown 2 The 5V and...

Страница 29: ...Rev C 28 6 4 3 Current profiles The 12V top and 5V bottom current profiles for the Enterprise Capacity 3 5 HDD drives are shown below Figure 1 12TB model current profiles Note All times and currents...

Страница 30: ...r for typical random read operations refer to the following I O rate curve see Figure 2 Locate the typical I O rate for a drive in the system on the horizontal axis and read the corresponding 5 volt c...

Страница 31: ...ations After the temperatures stabilize measure the case temperature of the drive See Figure 3 for HDA case temperature measurement location b Non operating 40 to 158 F 40 to 70 C package ambient with...

Страница 32: ...of 11ms half sinewave Shock occurring at abnormal levels may promote degraded operational performance during the abnormal shock period Specified operational performance will continue when normal opera...

Страница 33: ...in 1070 mm against a concrete floor or equivalent Figure 4 Recommended mounting Package size Packaged product weight Drop height 600 cu in 9 800 cu cm Any 60 in 1524 mm 600 1800 cu in 9 800 19 700 cu...

Страница 34: ...9 dB above the masking noise when measured according to Seagate specification 30553 001 6 6 6 Air cleanliness The drive is designed to operate in a typical office environment with minimal environment...

Страница 35: ...dard documented in SFF 8301 and SFF 8323 found at www sffcommittee org Note The image is for mechanical dimension reference only and may not represent the actual drive 2X 1 625 020 2X 3 000 010 1 432...

Страница 36: ...drive s owner to enable or disable firmware download operations see Section 7 4 Access to the Admin SP is available using the SID Secure ID password or the MSID Manufacturers Secure ID password 7 2 2...

Страница 37: ...Design Center Three conditions must be met before the drive will allow the download operation 1 The download must be an SED file A standard base drive non SED file will be rejected 2 The download fil...

Страница 38: ...ed to do so performs error recovery procedures to attempt to recover the data The error recovery procedures used depend on the options previously set in the Error Recovery Parameters mode page Error r...

Страница 39: ...ubsequent write command Sites are marked for DAR during read operations performed by the drive When a write command is received for an LBA marked for DAR the auto reallocation process is invoked and a...

Страница 40: ...daries across the interface if RDPROTECT and WRTPROTECT bits are nonzero values Type 1 does not allow the use of 32 byte commands Type 2 Provides checking control and additional expected fields within...

Страница 41: ...tructions provided by the host system This connects the drive directly to the system s SAS connector The SAS connector is normally located on a SAS backpanel See Section 10 4 1 for additional informat...

Страница 42: ...side mounting holes If mounting the drive using the bottom holes ensure the drive is not physically distorted by attempting to mount it on a stiff non flat surface The allowable mounting surface stiff...

Страница 43: ...erent SCSI domains Each drive port has a unique SAS address The two ports have the capability of independent port clocking e g both ports can run at 12Gb s or the first port can run at 6Gb s while the...

Страница 44: ...Inquiry 12h Y Block Device Characteristics B1h Y Block Limits B0h Y Date Code page C1h Y Device Behavior page C3h Y Device Identification 83h Y Extended Inquiry Data 86h Y Firmware Numbers page C0h Y...

Страница 45: ...e 02h Y Mode Select same pages as Mode Sense 1Ah 15h Y 2 Mode Select 10 same pages as Mode Sense 1Ah 55h Y Mode Sense 1Ah Y 2 Caching Parameters page 08h Y Control Mode page 0Ah Y Disconnect Reconnect...

Страница 46: ...3h 0Ch Y Report Supported Task Management Functions A3h 0Dh Y Report Timestamp A3h 0Fh Y Request Sense 03h Y Actual Retry Count bytes Y Extended Sense Y Field Pointer bytes Y Reserve 16h Y 3rd Party R...

Страница 47: ...Y Verify 10 2Fh Y BYTCHK bit Y Verify 10 2Fh Y Verify 12 AFh N Verify 16 8Fh Y Verify 32 7Fh 000Ah N Supported if formatted for type 2 protection information Write 6 0Ah Y Write 10 2Ah Y DPO bit Y FU...

Страница 48: ...epresenting the eight digits of the product serial number Bytes 16 through 26 reflect model of drive The table above shows the hex values for Model ST12000NM0027 Refer to the values below for the valu...

Страница 49: ...torage location on the media prior to shipping 3 Current values Current values are volatile values being used by the drive to control its operation A Mode Select command can be used to change the valu...

Страница 50: ...00 00 00 00 1C 20 00 00 CHG 04 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Verify Error Recovery 07h DEF 07 0A 00 14 FF 00 00 00 00 00 FF FF CHG 07 0A 0F FF 00 00 00 00 00 00...

Страница 51: ...provided in the SAS Interface Manual Figure 8 Physical interface Table 10 Miscellaneous features Supported Feature or condition N Automatic contingent allegiance N Asynchronous event notification N S...

Страница 52: ...TUM B L 5 08 1 27 6X 1 27 14X 15 875 0 35MIN 15 875 33 43 0 05 B 4 90 0 08 0 84 0 05 22X 0 15 B P15 P1 S7 S1 SEE Detail1 0 30 0 05 4X 4 00 0 08 0 15 D 0 30 0 05 2X 41 13 0 15 B B C C A A 0 20 B 42 73...

Страница 53: ...A 0 30 0 05 x 45 5X 0 40 0 05 X 45 3X CORING ALLOWED IN THIS AREA 2 25 0 05 4 85 0 05 0 10 B E S14 S8 4 40 0 15 SEE Detail 2 3 90 0 15 SECTION A A SECTION C C A 0 35 0 05 45 R0 30 0 08 C 1 95 0 08 0...

Страница 54: ...out of the SAS device and a description of the functions provided by the pins Table 12 SAS pin descriptions Short pin to support hot plugging Power Disable T10 Industry Standard for remote management...

Страница 55: ...em to reduce inrush current to the drive during hot plugging 10 5 Signal characteristics This section describes the electrical signal characteristics of the drive s input and output signals See Table...

Страница 56: ...e receive losses in the system 2 A Feed Forward Equalizer FFE optimized to provide balanced receive margins over a range of channels bounded by the best and worst case channels as defined by the relev...

Страница 57: ...ted States 408 658 1000 ASIA PACIFIC Seagate Singapore International Headquarters Pte Ltd 7000 Ang Mo Kio Avenue 5 Singapore 569877 65 6485 3888 EUROPE MIDDLE EAST AND AFRICA Seagate Technology SAS 16...

Отзывы: