28
Pulsar XT.2 SAS Product Manual, Rev. B
7.4
Power dissipation
400GB models in 6Gb operation
Typical power dissipation under idle conditions in 6Gb operation is 5.92 watts 20.20 BTUs per hour).
To obtain operating power for typical random write operations, refer to the following I/O rate curve (see Figure
4). Locate the typical I/O rate for a drive in your system on the horizontal axis and read the corresp5
volt current, +12 volt current, and total watts on the vertical axis. To calculate BTUs per hour, multiply watts by
3.4123.
Figure 4.
400GB (at 6Gb) DC current and power vs. input/output operations per second
200GB models in 6Gb operation
Typical power dissipation under idle conditions in 6Gb operation is 4.04 watts (13.79 BTUs
per hour).
To obtain operating power for typical random write operations, refer to the following I/O rate curve (see Figure
5). Locate the typical I/O rate for a drive in your system on the horizontal axis and read the corresp5
volt current, +12 volt current, and total watts on the vertical axis. To calculate BTUs per hour, multiply watts by
3.4123.
Figure 5.
200GB (at 6Gb) DC current and power vs. input/output operations per second