Module Replacement
49
5
Close the drawer using the instructions in section
6.2.2, “Closing a Drawer”, on page 45
Note
The drawers must be populated with drives in whole rows at a time (there are 3 rows of 14 drives per
drawer). The minimum number of drives in an enclosure is 14, the number of rows must not differ by
more than 1 between top and bottom drawers and the rows should be populated from the front to the rear
of the enclosure.
Note
The SP-3584 enclosure is not compatible DDICs intended for the previous generation SP-2584
enclosure. A keying mechanism will prevent insertion.
6.4 Replacing a Cooling Module
6.4.1 Removing a Cooling Module
Important
Before removing a module, make sure you have a replacement module to insert.
1
Identify the cooling module to be removed. If the module has failed, the fan fault LED will be lit amber
(see
).
Figure 6–7
Latch Position of a Correctly Inserted Drive