Operation
31
4.4 Unit Identification Number
4.4.1 How To Set the Unit Identification Number
The unit identification number is not set before the first system power on. The display is set to “00”
(flashing). The enclosure continues to power up even if the unit identification number is not set.
To set the unit identification number:
1
Press and hold the Input switch on the ops panel for a period of five seconds. The left-hand digit flashes.
2
Press and release the Input switch to increment the number until the required digit is reached.
3
Press and hold the Input switch for a period of five seconds. The right-hand digit flashes.
4
Press and release the Input switch to increment the number until the required digit is reached.
5
Press and hold the Input switch for a period of five seconds to finish setting the number.
Values of “01” to “99” are valid.