Medalist 13640, 10230, 6422 and 3210 Product Manual, Rev. B
9
During Standby mode, the drive accepts commands, but the drive is not
spinning, and the servo and read/write electronics are in power-down
mode.
1.7.1.1 Typical current profile
Figure 1 shows a typical current profile.
Figure 1. Typical startup and operation current profile
Mode
Typical Watts RMS
Typical Amps RMS
5V
12V
Spinup
—
0.72
2.2 (Peak)
Seeking
(Random,
no read/write)
9.7
0.5
0.65
Read/Write
6.1
0.675
0.275
Operating
6.1
0.575
0.30
Idle
5.5
0.5
0.25
Standby
1.1
0.22
—
Sleep
1.1
0.22
—
0
9
1
8
7
6
5
4
3
2
Time (seconds)
2.0
0
0.5
1.0
1.5
Current (Amps)