12
Cheetah NS SAS Product Manual, Rev. B
4.2.2
Format command execution time (minutes)
Execution time measured from receipt of the last byte of the Command Descriptor Block (CDB) to the request
for a Status Byte Transfer to the Initiator (excluding connect/disconnect).
4.2.3
General performance characteristics
4.3
Start/stop time
The drive accepts the commands listed in the SAS Interface Manual less than 3 seconds after DC power has
been applied.
If the drive receives a NOTIFY (ENABLE SPINUP) primitive through either port and has not received a START
STOP UNIT command with the START bit equal to 0, the drive becomes ready for normal operations within 30
seconds (excluding the error recovery procedure).
If the drive receives a START STOP UNIT command with the START bit equal to 0 before receiving a NOTIFY
(ENABLE SPINUP) primitive, the drive waits for a START STOP UNIT command with the START bit equal to 1.
After receiving a START STOP UNIT command with the START bit equal to 1, the drive waits for a NOTIFY
(ENABLE SPINUP) primitive. After receiving a NOTIFY (ENABLE SPINUP) primitive through either port, the
drive becomes ready for normal operations within 30 seconds (excluding the error recovery procedure).
If the drive receives a START STOP UNIT command with the START bit and IMMED bit equal to 1 and does
not receive a NOTIFY (ENABLE SPINUP) primitive within 5 seconds, the drive fails the START STOP UNIT
command.
The START STOP UNIT command may be used to command the drive to stop the spindle. Stop time is 30 sec-
onds (maximum) from removal of DC power.
There is no power control switch on the drive.
ST3400755SS
Maximum (with verify)
180
Maximum (without verify)
100
Sustainable disk transfer rate*:
Minimum
54 Mbytes/sec
Maximum
97 Mbytes/sec
SAS Interface maximum instantaneous transfer rate
300 Mbytes/sec* per port
(dual port = 600 Mbytes/sec*)
Logical block sizes
Default is 512-byte data blocks
Sector sizes variable to 512, 520, 524, and 528 kbytes.
Read/write consecutive sectors on a track
Yes
Flaw reallocation performance impact (for flaws reallocated at format time using
the spare sectors per sparing zone reallocation scheme.)
Negligible
*Assumes no errors and no relocated logical blocks. Rate measured from the start of the first logical block transfer to or
from the host.
Содержание Cheetah NS SAS ST3400755SS
Страница 1: ...Product Manual Cheetah NS SAS 100453994 Rev B August 2007 ST3400755SS ...
Страница 6: ...2 Cheetah NS SAS Product Manual Rev B ...
Страница 8: ...2 Cheetah NS SAS Product Manual Rev B ...
Страница 12: ...6 Cheetah NS SAS Product Manual Rev B ...
Страница 16: ...10 Cheetah NS SAS Product Manual Rev B ...
Страница 28: ...22 Cheetah NS SAS Product Manual Rev B ...
Страница 38: ...32 Cheetah NS SAS Product Manual Rev B ...
Страница 46: ...40 Cheetah NS SAS Product Manual Rev B ...
Страница 72: ...66 Cheetah NS SAS Product Manual Rev B ...
Страница 79: ......