background image

• 200 kHz Echosounder transducer  
 

- Digital smart transducer 

            - 7 degree beam 
            - Bottom tracking technology 
            - QA Sonar strength signal 
            - Breakaway design 

• 12-volt power supply/charger  
           - Rapid Charge 
           - Discharge feature 
           - Charge disconnect when battery is fully charged 

• Serial interface cable 
           - Used for data transfer 

• Training CD-ROM  
           - User Manual  
           - Other programs 

• 1-year Warranty parts & labor 

 

Options

 

• HydroLite-TM Pole Kit 
• Custom Case 
• GPS 
• Datalogger 
• Software 
• Sidescan Sonar 
 

Getting Started 

The Sonarmite echosounder can be used in multiple configurations.  
• Log in Hypack or other hydrographic survey software on laptops 
• Using DGPS  
• RTK GPS 
• Survey Topo Software on data collectors 
• SM Mobile Software 
• RC Unmanned Boats 
• Robotic Total Stations 
 

Switching the System On

 

Plug in the Transducer cable to the control box; look for a blinking red LED light. Red 
light indicates that the system is on and outputting depths. The transducer MUST be in 

Содержание SonarM8

Страница 1: ...time We cut the Army s system down from 3 cases to one pelican case also the ease of operation was appreciated As time went on we began building the systems in our Northern California facility upgradi...

Страница 2: ...parts labor Options HydroLite TM Pole Kit Custom Case GPS Datalogger Software Sidescan Sonar Getting Started The Sonarmite echosounder can be used in multiple configurations Log in Hypack or other hy...

Страница 3: ...specific setup guides for your system http www seafloorsystems com support html Bar checking Bar checking is calibrating the system for the sound velocity of the water you will survey in There are on...

Страница 4: ...uetooth or serial to laptop software is included on Sonarmite CD 4 View streaming data Control F will cycle through the output formats below Control S will save the output format Control R will reset...

Страница 5: ...below SMDBT 1 6 f 0 48 M 5C SMDBT 1 6 f 0 48 M 5C SMDBT 1 6 f 0 48 M 5C SMDBT 1 6 f 0 48 M 5C SMDBT 1 6 f 0 48 M 5C SMDBT 1 6 f 0 48 M 5C This is a standard NMEA output which can be used with various...

Страница 6: ...500 8 9 0 This is the system format here you change the sound velocity output Control U will increase from the default 1500 and Control D will decrease in increments of 10 When you are satisfied with...

Страница 7: ...d is between two and four mph the slower you go the more soundings you will log Surveying in a grid format is the best way to ensure proper coverage of the survey area F A Q Is Dual Frequency required...

Страница 8: ...check the Barcheck was normally also performed at the start and end of a survey There are several problems with this method The location of the barcheck is only relevant to the water column at that pa...

Страница 9: ...pattern versus output power applied This generally means that the spread beamwidth of the transmitted ultrasound increases with amplitude Most modern echo sounders use a Digital Signal Processing DSP...

Страница 10: ...in shallow water situations with multipath reflections What is Latency Latency is the time difference between a position and depth being recorded the topic is extremely complex and can included some...

Страница 11: ...ure of the water sample Pressure Sum of water depth and barometric pressure All of the above parameters can vary considerably in any particular water column but the assumption made with a single beam...