0.01 Active alarms causing out of service
This parameter shows the active alarms that are causing the current out of service state.
DG0
DG1
DG2
DG3
DG4
DG5
DG6
0 0 1 0
DG456
=
[0.01.0]
To scroll through the list (consisting of a maximum of 16 alarms)
set the cursor on DG3456 and press the ˄
or ˅ push-buttons.
0.02 Alarms log
Parameter 0.02 shows the last 32 alarms registered. To scroll through the list (consisting of a maximum of 32
alarms) set the cursor on DG3456 and press the ˄ or ˅ push-buttons.
DG0
DG1
DG2
DG3
DG4
DG5
DG6
0 0 2 _
DG3
=
[0.02.1]
Number of times of consecutive triggering of
the alarm shown by DG456
DG456
=
[0.02.0]
DG0
DG1
DG2
DG3
DG4
DG5
DG6
0 0 2 0 0
DG56
=
[0.02.2]
Car position (floor number) when the alarm
was activated. 00 means “position not known”, while 01 is
the lowest floor
DG0
DG1
DG2
DG3
DG4
DG5
DG6
0 0 2
_
DG3456
=
[0.02.3]
Time elapsed from when the alarm was
activated, first part: days (0000
9999)
DG0
DG1
DG2
DG3
DG4
DG5
DG6
0 0 2 0 0
_
DG56
=
[0.02.3]
Time elapsed from when the alarm was
activated, second part: hours (00
23)