background image

GSM-R5-DIN_User_Manual_EN_v1-11.docx 

 

Strana 3 z 7

 

 

Caution 

 When  configurating  via  SMS  is  important  to  understand  that´s  only  change  of 
parameters and it will not match with configuration saved in PC. 
 

 

 

 

 

7.

 

Control 

7.1

 

Output control by “ringing” 

GSM

 rele

5

 is set by the manufacturer to switch ON an OUTPUT Y6 for 4 seconds when 

any user from the list of users calls to 

GSM

 rele

5

 phone number. This pulse is useful for 

an opening of an entry gate. Test this function by a call to 

GSM

 rele

5

 from your mobile 

phone  (it’s  important  to  send  a  valid  command  SMS  to 

GSM

 rele

5

  from  your  mobile 

phone if have inserted a “new” SIM card to 

GSM

 rele

5

). 

GSM

 rele

5

 rejects a call and at the same time generates a pulse on an OUTPUT Y6.   

 

7.2

 

Remote control of 

GSM rele

5

 via SMS 

GSM

 rele

5

 is controlled via SMS of the GMS network. Text SMS are in form: 

 
<PASSWORD> <COMMAND> [<COMMAND >] 

Password (access code) 

Password is a main security item for 

GSM

 rele

5

 control. Command SMS are accepted 

from any phone number. It means anybody who knows the password and the phone 
number can control the 

GSM

 rele

5

. The password is a string of digits (1 to 20) which 

must be on the beginning of any command SMS. Otherwise the SMS will be ignored. A 
text before the password is automatically ignored. It is useful when command SMS are 
sent from Internet GSM gates. The password can be changed using SEAConfigurator on 
the tab General or by a configuration SMS message. 
Default password set up by manufacturer: 

1234 

Command 

This part of a message specifies a requested action. See the following table for available 
commands. 

GSM

 rele

5

 commands are not a case sensitive, it’s possible to use upper 

letters as well as lower letters.  
Each command is preceded by Yx, where x is the number of controlled output. If output 
is not specified, the OUTPUT  (Y5) is used as default. Commands 

ON

 and 

Y5 ON

 and 

Y5ON

 has the same meaning. 

 

 
It´s possible to use multiple commands in one message separated by a space. 
E.g. 

1234 ON

   

… switch on device connected to output Y5 

1234 Y5 ON

 

… switch on device connected to output Y5 

1234 Y6 OFF

 

… switch off device connected to output Y6 

1234 Y6 PULSE 5

  … an OUTPUT Y6 will be switched on and then after 5 seconds 

will be switched off (Notes: if an output is already switched on, it will be just switched 
off after 5 seconds) 

1234 Y6 reg 5

 

… requested temperature for the function temperature regulation 

of OUTPUT Y6 will be set to + 5°C 
Using multiple commands in one SMS message can look like this: 

1234 Y5 OFF Y6 REG 25 

… switch off output Y5 and sets temperature regulation 

on output Y6 to 25 °C according to temperature sensor on input A3. 

Confirmation 

If a command message contains a valid password (access code) the 

GSM

 rele

5

 returns 

a confirmation message which informs if a command was accepted (see chapter Status 
SMS). If you don’t want a confirmation message (e. g. when sending a command SMS 
from the Internet GSM gates) add a command “

NOBACK

”. 

E.g. 

1234 Y5 ON NOBACK  

… 

GSM

 rele

5

 will switch on device on output Y5 and 

will not send message back. 

 

7.3

 

Local control of outputs 

GSM

 rele

5

 has 2 push buttons for local control of outputs Y5 a Y6 (see chapter 5.2). 

 

7.4

 

Status SMS message 

Whenever the command SMS contains valid password the 

GSM

 rele

5

 send back Status 

message.  

Note: if value of parameter 

Signal

 is ??, -- or== It´s an error. 

 

7.5

 

Control using CML (for Smart phones) 

This  application  can  use  smartphones  with  Android  or  iOS.  Application 
makes  easier  control  of 

GSM

 rele

5

  and  state  monitoring.  You  can 

download this application from   Google Play or Apple Store for free, type 
into search   „

CML SEA

“. After installing  the application, make  the  first 

registration, take a photo of the QR code of the device into the “paring code”. The QR 
code you find in the 

GSM

 rele

package

 

 

 

  

 

 

    

 

Command 

Parameter 

Meaning 

Y5 ON 

  Switch on output Y5 (

Y6 ON

 switch on output 

Y6) 

ON 

  If no output is specified, switch on output Y5 

Y5 OFF 

  Switch off output Y5 (

Y6 OFF

 switch off output  

Y6) 

OFF 

  If no output is specified, switch off output Y5 

Y5 PULSE 
Y5 RESET 


 

 Switch on output Y5 for 5 seconds creating pulse. 

Reset output Y5 for 5 seconds. 

PULSE 

RESET 

 

  If no output is specified, create 5 sec pulse on          

output Y5 

  If no output is specified, reset output Y5 

REG 

 

0 to 55 

Setting of requested temperature and starts 

regulation mode. Request of status SMS (state of 
inputs, outputs, temperatures, signal quality and 
credit). 

STATE 

Request of status SMS (state of inputs, outputs, 

temperatures, signal quality and credit). 

Command 

Meaning 

NOBACK 

No confirmation SMS will be sent 

Example of status SMS  message 

Meaning 

Base station: Y5 ON OK 

Command confirmation: Y5 is switched on. 

X1=ON 

State of input number 1 

X2=OFF 

State of input number 2 

A3=28'C 

State of input number 3 

A4=5.0V 

State of input number 4 

Y5=ON 

State of output number 1 

Y6=OFF 

State of output number 2 

Power=good 

Power state (from battery or power supply) 

Battery=100% 

State of battery charge 

Signal=58% 

State of GSM Signal 

Содержание GSM-R5-DIN

Страница 1: ...a confirmation SMS message on performing the operation The password 1234 can be changed later in configuration The GSM rele5 reacts on the SMS text message from any telephone as long as the access pa...

Страница 2: ...king on symbol window with hint will appear LED COLOR Meaning Off On Blink 1 per 3s 1 1 PWR green device is off powered from 230 V AC powered from backup battery ERR red no error error GSM blue No GSM...

Страница 3: ...ature regulation of OUTPUT Y6 will be set to 5 C Using multiple commands in one SMS message can look like this 1234 Y5 OFF Y6 REG 25 switch off output Y5 and sets temperature regulation on output Y6 t...

Страница 4: ...ed by the best software engineers in SEA and was carefully tested both in SEA and also by SEA customers using GSM applications products made in SEA In spite of making all possible to get error free so...

Страница 5: ...Y5 ON heat up to 22 C a 1234 Y5 OFF turn off heater If temperature drops below 5 C Output Y5 will be switched on and regulates to nonfreezing temperature If you have enabled heating to freezing tempe...

Страница 6: ...to 25 C 1234 Y6 OFF Y5 TEPL 25 thermoregulator is disabled Regulation to 22 C 1234 Y6 ON Y5 OFF thermoregulator is set to 22 C Regulation to 7 C 1234 TEPL 7 thermoregulator is disabled 10 3 Digital i...

Страница 7: ...le operator for help if necessary Check credit on a pre paid SIM card Ask your mobile operator for help if necessary Test the SIM card in your mobile phone The mobile phone should show the signal leve...

Отзывы: