NOTICE

SEA s.r.l can not be deemed responsible for any damage or accident caused 
by product breaking, being damages or accidents due to a failure to comply 
with the instructions herein. The guarantee will be void and the manufacturer 
responsibility (according to Machine Law) will be nullified if SEA Srl original 
spare parts are not being used.

This is a 

quotation from the GENERAL NOTICE that the installer must read carefully 
before installing.

Packaging materials such as plastic bags, foam polystyrene, nails etc must 
be kept out of children’s reach as dangers may arise. 

The electrical installation shall be carried out by a professional technician 
who will release documentation as requested by the laws in force. 

Sistemi Elettronici

di Apertura Porte e Cancelli

International registered trademark n. 804888

®

7

6

3

4

2

1

5

CORONA S/RP

Fig. 28

67410622

Rev 00 - 02/2012

8. TYPICAL INSTALLATION

9. PERIODICAL MAINTENANCE

Verify the smooth sliding of the chain

Verify the tightening of the chain

Verify the stability of the ceiling and 

door junctions

Verify the door is in a good state and 

that the slides are not dirty

Verify the tension of the steel cable of 

the external release

Verify the general condition of the operator 

(transformer, motor, electronic control unit)

Keep the chain and the sliding support

lubricated

Semestral

Semestral

Semestral

Annual

Annual

Annual

Semestral

All the above described operations must be made 
exclusively by an authorized installer.

SAFETY PRECAUTIONS:

All electrical work should conform to current regulations. A 16 A   0,030 A differential switch must be incorporated into the source of the operators 
main electrical supply and the entire system properly earth bonded. Always run mains carrying cables in separate ducts to low voltage control 
cables to prevent mains interference.

INTENDED USE:

The CORONA S/RP operator has been designed to be solely used for the automation of sectional doors and balancing doors. 

SPARE PARTS:

To obtain spare parts contact: 

SEA s.r.l. -Zona Ind.le, 64020 S. ATTO   Teramo   Italia

SAFETY AND ENVIRONMENTAL COMPATIBILITY:

Don’t waste product packing materials and/or circuits.
When being transported this product must be properly packaged and handled with care.

CORRECT DISPOSAL OF THIS PRODUCT (WASTE ELECTRICAL & ELECTRONIC EQUIPMENT) - EUROPE ONLY

(Applicable in the European Union and other European countries with separate collection systems)
This marking shown on the product or its literature, indicates that it should not be disposed with other household wastes at the end of its 
working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from 
other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local government office, for details of where 
and how they can take this item for environmentally safe recycling. 

LIMIT OF GUARANTEE

For the guarantee see the sales conditions on the official SEA price list.

MAINTENANCE AND OUT OF SERVICE:

The decommission and maintenance of this unit must only be carried out by specialised and authorised personnel.

NOTE: THE MANUFACTURER CAN NOT BE DEEMED RESPONSIBLE FOR ANY DAMAGE OR INJURY CAUSED BY IMPROPER USE OF 
THIS PRODUCT.

  

 

SEA

 

reserves the right to do changes or variations that may be necessary to its products with no obligation to notice.

ENGLISH

18

1) CORONA S/RP operator
2) On board receiver 
3) Left photocell
4) Right photocell
5) Start-Stop button
6) Safety box for external release
7) Warning lamp

Содержание CORONA 110

Страница 1: ...ushing safety is assured by an electronic system which set during installation stops the door in opening and reverses during closing phase Corona S RP irreversibility avoids the use of electro locks while guaranteeing maximum security during forcing attempts A Manual Release ensures door operation also in case of power failure ENGLISH MAIN PARTS OF THE CORONA S OPERATOR MAX DOOR MAX DOOR DIMENSION...

Страница 2: ...ed screws B into the holes of the aluminium profiles Fig 4 Connect the two ends of the chain using the connecting link and the two provided screws Fig 5 Make sure that the chain has been correctly mounted on the pinion of the Corona S body Fig 7 A Place the guide on the stop of the Corona S body and fix it with the special bracket Fig 7 B Mount the front fixation support on the other end of the gu...

Страница 3: ... making sure that it s placed iat the centre of the door Fix the anchor bracket to the door frame or if necessary on the wall using rivets or bolts Fig 8 Lift the Corona S and fix it to the ceiling with the special brackets keeping a maximum distance of 400 mm from the ceiling and making sure that the operator is in a perfectly horizontal position Fig 9 Release the Corona S operator and drag the d...

Страница 4: ...m Min 90 Fig 10 Fig 12 Fig 13 Fig 14 1 2 3 up to 2 7 H x 3 L m up to 2 7 H x 3 L m CORONA60 CORONA60 up to 2 7 H x 4 L m up to 2 7 H x 4 L m CORONA110 CORONA110 OPERATORS FOR COUNTERBALANCED OVERHEAD DOORS MAX DOOR MAX DOOR DIMENSIONS DIMENSIONS ENGLISH Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n 804888 Fig 11 CORONA S RP 67410622 Rev 00 02 2012 14 We reco...

Страница 5: ...e Release knob Fixing bracket U shaped bracket To adjust the door closing as precise as possible release the bolts on the curved rod and adjust the run on the two holes Fig 15 CONNECTION OF THE OPERATOR CORONARPWITH THE GUIDE TRACK Before installing the operator remove all unnecessary ropes or chain and disable any equipment such as locks not needed for powdered operation Before installing the ope...

Страница 6: ... 18 Fig 19 Fig 20 Fig 21 Fig 22 67410622 Rev 00 02 2012 Centre line Wall Door ENGLISH 16 5 INSTALLATION OF THE GUIDE ON THE WALL AND ON THE CEILING FOR CORONA RP Guide Wood Thikness 25mm junction in the space within door and guide Sleigh After having fixed the operator to the hanging firmware remove the wood ...

Страница 7: ...e bend link lever the link lever and the sleigh Fig 25 Install the the manual release at a height of max 1 8m The warning boards against entrapment should be permanently fixed in a known place or near any fixed control The notice concerning the manual release should be permanently fixed next to said release After installation make sure that the mechanism is properly adjusted and that the drive rev...

Страница 8: ...ways run mains carrying cables in separate ducts to low voltage control cables to prevent mains interference INTENDED USE The CORONAS RPoperator has been designed to be solely used for the automation of sectional doors and balancing doors SPARE PARTS To obtain spare parts contact SEAs r l Zona Ind le 64020 S ATTO Teramo Italia SAFETYAND ENVIRONMENTALCOMPATIBILITY Don t waste product packing materi...

Страница 9: ...STEM FOR CORONA S To release the operator work as follows Turn the knob and open the door manually Fig 30 Notice This release system allows the external releasing of the door Fig 29 ENGLISH Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n 804888 19 Fig 30 To the attention of users and technicians CORONA S RP 67410622 Rev 00 02 2012 ...