SEA USA USER 1 24V DG R1 Скачать руководство пользователя страница 17

9 10 11 12 13

E

dg

e

A

U

X

C

om

m

on

F

L(

-)

CN1

Security edge

MOTOR POWER SUPPLY 

Power input

Input for the connection of the electric 
power.
P = SINGLE PHASE 120V~
N = NEUTRAL
G  = GROUND

N O T I C E :  

f o r   t h e  

connection to the electric 
power see the law in force.

TRANSFORMER

3,6 A blow fuse on 230V ~ power supply
6,3A blow fuse on 115V ~ power supply

17

G

N

115V~

o

230V~

P

POWER 

(CN8)

P      G     N

MOTOR 

(CN6)

M+

M-

1

2

P      G     N

+

-

CN1

1

2

3 4

5

6

7

8

9 10 11 12 13

S

ta

rt

SECURITY EDGE

Between clamps   9 and 11 of CN 1 it is possible to connect an active safety edge on the terminal   M8. If this 
device is pressed it opens the contact causing a partial inversion of the movement both in opening and in 
closing.   If not used you must put a jumper between   the contacts GND and 9 of CN1.
Note1: contact N.C.
Note2: Through the on-board display or the Jolly programmer it is possible to activate the balanced edge 
8K2, in this case the edge contact is controled by a special resistance value revealing the eventual 
involuntary short- circuit   of the device. In case of imbalance of the device a special alarm will show on the 
on-board dispaly or on the JOLLY programmer.

SECURITY EDGE AND WARNING LAMP OR BUZZER

EXTERNAL RECEIVER 

Example: Connection of a 
radio receiver

For the connection of the 
receiver refer to the relative 
instructions manual.

C

om

m

on

C

om

m

on

S

ta

rt 

pe

d.

-

+

Flashing Lamp  24V       15W  (Warning lamp ) or Buzzer
The flashing lamp or buzzer can be connected between the clamps 24V (Accessories) and   FL (-) of CN 1.

The warning lamp or buzzer advises that the automatic gate is moving with 1 flash/second in opening and 2 flashes / second in closing. During 
pause it remains switched on. Through the warning lamp or buzzer it is also possible to identify alarms lied to the STOP, PHOTOCELL 1, 
PHOTOCELL 2 and EDGE devices. Through the display or the JOLLY programmer it is possible to activate the pre-flashing function   and/or to 
modify the function of the warning lamp/buzzer choosing between fix flashing, control lamp or Buzzer.

WARNING:
K e e p   t h e   p o w e r  

c a b l e s   ( m o t o r s ,   p o w e r  
supply)  SEPARATE from the 
command cables (push 
buttons, photocells and so 
on). In order to avoid any 
interference it’s preferable to 
foresee and use two separate 
sheaths.

BUZZER

International registered trademark n. 2.777.971

USER 1 - 24V DG R1 

24

V

 (A

cc

es

so

rie

s)

24

V

 (A

cc

es

so

rie

s)

67411535

REV 07 - 06/2014

Содержание USER 1 24V DG R1

Страница 1: ...ES AND BARRIERS 67411535 REV 07 06 2014 International registered trademark n 2 777 971 SEA USA Inc 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 USA Tel Toll free 1 305 594 1151 1 305 594 7325 800 689 4716 web site www sea usa com e mail sales sea usa com ...

Страница 2: ...xternal controls and devices serving as required protection against entrapment shall be provided with the operator when such controls are shipped with the operator Instructions regarding intended installation of the gate operator shall be supplied as part of the installation instructions or as a separate document The following instructions or the equivalent shall be supplied where applicable a Ins...

Страница 3: ...al landscaping or similar obstruction A wireless contact sensor shall function under the intended end use conditions 6 One or more contact sensors shall be located on the inside and outside leading edge of a swing gate Additionally if the bottom edge of a swing gate is greater than 6 inches 152 mm above the ground at any point in its arc of travel one or more contact sensors shall be located on th...

Страница 4: ...fet R1 Motors command relay R2 Motors command relay PR1 Rectifier jumper F1 Fuse 10 AT CN8 F1 CN1 CNA CN3 CN5 CNP CN6 RL2 RL1 CN2 CN4 CN7 UP DOWN OK RD3 RD1 PR1 DISPLAY 1 2 3 4 5 6 7 8 9 10 11 12 13 1 EXP POWER FUSE BATTERY S MOTOR LIGHT MASTER SLAVE PROG RADIO MODULE JOLLY LIMIT SWITCH 156 mm 6 inches 100 mm 4 inches RECEIVER RX JOLLY JOLLY2 TECHNICALSPECIFICATIONS Control unit power supply Absor...

Страница 5: ...sion 34 Flash Photocell 2 1 2 3 4 5 6 7 8 9 10 11 12 13 CN1 ANT COM START PEDST STOP COM PH1 PH2 EDGE AUX COM 24V FL Start Stop Common Antenna START Ped Common Photocell 1 Common AUX 24V 200 mA max 24V 750 mA max Accessori Safety edge Flash Photocell 2 Optional WARNING The control unit is designed with the automatic detection of not used N C inputs photocells Stop and Limit switch except the SAFET...

Страница 6: ...to main menu With UP or DOWN choose a delay for automatic closing To confirm and return to main menu Skip this step if you wna tto work in half automatic logic With UP or DOWN Choose ON To confirm and return to main menu With UP or DOWN choose ON to start times learning At the end of the selflearning the control unit returns automatically to the main menu With UP or DOWN Choose ON to start test To...

Страница 7: ... nt 4 eters U Spr nt 5 eters U Stor 5 eters U U Stor 6 eters U U Stor 7 5 eters U U satvrn Er vry 800 U Uergl 5 eters U Uergl 4 eters U Uergl 3 eters U Sl d ng Sl d ng U 4 reuerse otor 5 log Avto at U open stop lose stop open 2 bvttons safety Dead an U open stop lose open 6 paVse t e U Pedestrian Start Delete single transmitter Sliding Synchronized right motor Synchronized left motor Automatic Ste...

Страница 8: ...osing reverses the movement STEPBYSTEPTYPE 1 LOGIC The start impulse follows the OPEN STOP CLOSE STOP OPEN logic STEPBYSTEPTYPE 2 LOGIC The start impulse follows the OPEN STOP CLOSE OPEN logic DEAD MAN LOGIC The gate opens as long as the START button of opening is pressed releasing it the gate stops The gate closes as long as the button connected to the PEDESTRIAN START is pressed releasing it the...

Страница 9: ...al menu move on one of the menu and press the buttons at the same time for 5 s For exiting the special menu move on one of the menu and press the buttons at the same time for 5 s Description Set Value Setting from 30 to 100 Setting from 30 to 100 Setting from 10 to 100 Setting from 10 to 100 Disabled Disabled Setting from 5 to 100 Setting from 5 to 100 Pre flashing active only before closing Contr...

Страница 10: ... pausing time Photocell active before opening The photocell stops in closing and closes when released Photocell active in closing Photocell active in opening and closing The photocell gives a command to close during opening pause and closing The photocell charging the pausing time Photocell active before opening The photocell stops in closing and closes when released Normal N C contact If the phot...

Страница 11: ... Adjusts the amperometric tolerance in relation to the detected stop in closing Adjust the amperometric tolerance in relation to the detected stop in opening Disabled PXOTO1 2 The flashing light remains ON with active timer and open gate The flashing light remains OFF with the active timer and open gate Adjustable from 10 to 99 Increasing the value the reversing on obstacles will be delayed 21 24u...

Страница 12: ...rease or decrease the number press OK to confirm it and you will pass automatically to the entering of the next number Pressing OK after the last entered number the word SvRE appears confirm the activation of the PASSWORD and the message Ok appears pressing UP or DOWN instead you can cancel the operation and NO OPERATION will appear on the display Once entered the PASSWORD it will be definitively ...

Страница 13: ... must be N O If activating the related command on the display the item SET lights up the input will be working If SET is always on check the wirings Safety edge test Photocell 1 test Photocell 2 test The contact must be N C If activating the related command on the display the item SET lights up the input will be working If SET is always on make sure that the contact is a N C one The contact must b...

Страница 14: ...rmine the type of the remaining radio transmitters If the receiver is a Rolling Code press twice the button of the radio transmitter that you want to program to memorize the first TX Notes Enter radio transmitters learning only when the working cycle stops and the gate is closed You can store max 2 of the available 4 functions If the control unit receives a code which was already associated to ano...

Страница 15: ...an start can be connected between the clamps 2 and 4 of the CN1 terminal This input allows a partial opening the opening space can be set through the on board display or through the JOLLYdevice Note1 The contact for partial opening is a N O Contact Normally open Note2 In 2 BUTTONS logic it is necessary to keep pressed the Start Ped to re close the automation Note3 In dead man logic this button exe...

Страница 16: ...switch can be connected through the special LIMIT SWITCH connector on the control unit The control unit can administrate mechanical inductive and magnetic limit switches Only on some special applications il will not be necessary to connect the limit switches The control unit will automatically realize if limit switches are present or not 1 Through the on board display or through the JOLLY programm...

Страница 17: ...alarm will show on the on board dispaly or on the JOLLYprogrammer SECURITY EDGE AND WARNING LAMP OR BUZZER EXTERNAL RECEIVER Example Connection of a radio receiver For the connection of the receiver refer to the relative instructions manual Common Common Start ped Flashing Lamp 24V 15W Warning lamp or Buzzer The flashing lamp or buzzer can be connected between the clamps 24V Accessories and FL of ...

Страница 18: ...t Note 1 The master and slave settings on the control unit are present in the special menu selecting ASter slaue Note 2 All these operations can also be managed through the JOLLY programmer Note 3 On the SLAVE it is possible to set the following functions only torque speed motor type slowdown speed acceleration deceleration position recovery AUX and motor inversion All other parameters will be set...

Страница 19: ...charge 200mA BAT GND PSOL BAT 28V GND CN1 S GND GND Solar Panel Batteries 12V 12V charge 360mA charge 800mA Cod 23101105 800 360 200 12 or 16 7 2 19 International registered trademark n 2 777 971 USER 1 24V DG R1 CONNECTION OF BATTERIES TO BATTERY CHARGER CARD Specifications of optional batteries 24V Pb 1 2Ah min 67411535 REV 07 06 2014 ...

Страница 20: ...TROUBLE SHOOTING Advises Make sure all Safeties are turned ON Problem Found Possibile Cause Solutions Motor doesn t respond to any START impulse Gate doesn t move while the motor is running Gate doesn t reach the complete Open Closed position The gate opens but doesn t close The gate doesn t close automatically a Check the connected N C contacts b Burnt fuse a The motor is in the released position...

Страница 21: ... the original buyer only Hydraulic and oil bath motors 36 months warranty from the date of invoice on manufacturing assembling and workmanship defects Electro mechanic motors and electronic control systems 24 months warranty from the date of invoice on manufacturing assembling and workmanship defects Lepus and Full Tank Standard model 60 months warranty from the date of invoice on manufacturing as...

Страница 22: ......

Страница 23: ......

Страница 24: ...c 10850 N W 21st unit 160 DORAL MIAMI Florida FL 33172 USA Tel Toll free 1 305 594 1151 1 305 594 7325 800 689 4716 web site www sea usa com e mail sales sea usa com International registered trademark n 2 777 971 ...

Отзывы: