MENU SP
Default
SET
----
----
Mechanical limit switch
Description
Set Value
35 - passuord
34 - TYPE OF L T SU T(X
U
U
E(XAN (AL
Agnet (
U
END
U
E(XAN (AL
Magnetic limit switch
Allows the entering of a
password which blocs the
modification of the control unit
parameters.
Select END and press OK to exit the special menu.
The special menu deactivates automatically after 20 minutes.
Note 1
: The * indicates that the default value may change depending on the selected motor type.
Note 2
: After initialization the parameters "motor type" and "limit switch type" remain son the value chosen in
the setup program.
0 50
33 - aster-slaue
U
aster
U
Slaue
off
off
0
*
10
Off
10 99
31 - (LOS NG SENS T U TY
32 - PXOTO off n (LOS NG
Disabled
Setting from 10 to 99
Setting from 0 to 50
For applications with two
motors in master-slave,
you can set the control
unit as slave
For applications with two
motors in master-slave, it
allows to set the control
unit as master
Disabled
With a new control unit all menus can be displayed and set and the password will be disabled.
Selecting one of the Menus and keeping UP and DOWN pressed at the same time for 5 seconds, you will access the
SP Menu containing the
Passuord
Submenu.
Pressing OK in the
Passuord
Menu, you will proceed with the entering of the numeric code of the 4-digit
PASSWORD.
Use UP and DOWN to increase or decrease the number, press OK to confirm it and you will pass automatically to the
entering of the next number. Pressing OK after the last entered number the word
SvRE?
appears, confirm the
activation of the PASSWORD and the message
Ok
appears, pressing UP or DOWN instead you can cancel the
operation and
NO OPERATION
will appear on the display.
Once entered the PASSWORD, it will be definitively activated, once the display switch off timeout has expired, or by
turning off and on again the control unit. Once the PASSWORD has been activated, the menus of the display can be
only displayed but not set. To unlock them you must enter the correct PASSWORD in the
Passuord
menu, if the
password is wrong the message
ERRor
will appear.
At this point, if the password has been entered correctly, the menus will be unlocked and it will be possible to change
the parameters of the control unit again.
If the control unit has been unlocked through
Passuord
Menu, it is possible to enter a new and different password,
using the same entering process as for the first one; at this point, the old password will no longer be valid.
If the password has been forgotten, the only way to unlock the control unit is to contact the SEA technical assistance,
which will assess whether to provide the procedure to unlock the control unit or not.
Note:
The password cannot be set through the Jolly or Jolly 2 terminal.