Field Service Procedure – Pol Motor Kit, 6003A/6004
Page
6
of
6
Document No
135282 Rev B
Copyright © Sea Tel, Inc 2011 - The information contained in this document is proprietary to Sea
Tel, Inc.. This document may not be reproduced or distributed in any form without prior written
consent of Sea Tel, Inc.
11.
Drive
the
Polang
to
its
upper
and
lower
electrical
limits
and
verify
the
assembly
drives
in
the
correct
direction
and
that
the
feed
assembly
has
180
degrees
of
rotation:
On
the
ACU
press
the
arrow
key
to
display
cursor
underneath
Pol
value.
Press
and
hold
the
arrow
key
to
drive
the
feed
to
its
upper
end
stop
and
verify
the
LNB
is
horizontal
with
the
coax
cable
towards
the
left.
The
Pol
value
should
be
approximately
211
counts.
Now
press
and
hold
the
arrow
key
to
drive
the
feed
to
its
lower
end
stop
and
verify
the
LNB
is
horizontal
with
the
coax
cables
towards
the
right.
The
Pol
value
should
be
approximately
28
counts.
12.
In
the
DAC
setup
menu,
go
to
the
Pol
Type
parameter
and
set
antenna
back
into
Auto
Pol
Mode:
Press
and
hold
the
arrow
keys
together
until
the
‘EL
Trim’
or
‘Auto
Trim’
window
is
displayed.
Push
the
arrow
key
to
scroll
through
the
settings
until
the
‘Polang
Type’
window
is
displayed
and
press
the
arrow
key
to
activate
the
window.
Now
use
the
and
arrow
keys
to
scroll
the
cursor
along
and
use
the
and
arrow
keys
to
change
the
value
from
“0009”
to
“0072”
and
then
press
the
button
to
put
the
system
back
into
Automatic
Polang
(Auto
Pol)
mode.
Watch
the
LNB
and
verify
it
returns
to
the
correct
reception
position
(while
the
POL
motor
is
driving
the
target
light
will
be
illuminated
on
the
DAC).
13.
Save
the
settings
in
the
DAC
‐
2202:
Press
and
hold
the
arrow
keys
together
briefly,
“Save
New
Parameters”
will
be
displayed.
Press
the
arrow
key
to
activate
the
window
and
then
press
the
button,
“Parameters
Saved”
will
be
displayed
and
the
pol
type
and
pol
offset
will
be
stored
in
the
DAC.
Содержание 6003A