Field Service Procedure – Pol Motor Kit, 6003A/6004
Page
4
of
6
Document No
135282 Rev B
Copyright © Sea Tel, Inc 2011 - The information contained in this document is proprietary to Sea
Tel, Inc.. This document may not be reproduced or distributed in any form without prior written
consent of Sea Tel, Inc.
7.
Install
the
motor
to
the
feed
assembly,
apply
Loctite
242
to
the
mounting
threads
and
tighten
the
securing
nuts.
8.
Connect
the
IDC
connector
to
the
termination
block
and
secure
the
excess
cable
with
cable
ties.
8.
Pol
Alignment
and
Verification:
1.
Drive
the
reflector
to
zero
degrees
of
elevation
to
view
the
orientation
of
the
LNB:
Press
the
button
to
turn
the
Tracking
function
off
(if
applicable)
to
prevent
the
antenna
from
going
into
a
search.
Push
the
button
until
the
‘Antenna’
window
is
displayed
(the
screen
will
show
the
AZ,
EL
and
REL
values).
Press
the
button
twice
to
isolate
the
‘EL’
window
and
then
press
the
arrow
to
activate
it
(a
cursor
will
be
displayed).
Now
use
the
and
arrow
keys
to
scroll
the
cursor
along
and
use
the
and
arrow
keys
to
change
the
elevation
value
to
“00.0”
and
press
the
button.
2.
Set
Pol
Type
to
manual
mode:
Enter
the
‘Setup
Menu’
by
pressing
and
holding
the
arrow
keys
together
until
the
“EL
TRIM’
window
is
displayed.
Push
the
arrow
key
until
the
‘Polang
Type’
window
is
displayed.
Press
the
arrow
key
to
activate
the
window.
Now
use
the
and
arrow
keys
to
scroll
the
cursor
along
and
use
the
and
arrow
keys
to
change
the
characters.
Set
the
‘Polang
Type’
to
“0009”
which
is
manual
mode
and
press
the
button.
3.
Press
the
button
to
go
to
Pol
Offset
window
and
verify
the
default
setting
is
“0030”.
(If
necessary
use
arrow
keys
to
select
appropriate
digits
and
change
accordingly).
4.
Now
keep
pressing
the
button
until
the
‘Antenna’
window
is
displayed
(the
screen
will
show
the
AZ,
EL
and
REL
values).
5.
Press
the
button
4
times
until
‘POLxxx’
is
displayed
and
then
press
the
arrow
key
to
activate
the
window.
*Note:
It’s
advisable
to
have
someone
watching
the
feed
while
the
pol
is
driven.
Driving
the
LNB
past
its
normal
range
of
operation
can
cause
damage
to
the
assembly.
6.
Now
hold
either
the
or
arrow
key
to
rotate
the
Pol
until
a
count
of
“115”
is
displayed.
Содержание 6003A