Technical Specifications for CASSETTE Indoor Units 

 

 

Model Of Indoor Unit 

SMZCA12H4ZIGX 

SMZCA18H4ZIGX 

SMZCA24H4ZIGX 

 

Product Code 

243-6004-E 

243-6005-E 

243-6006-E 

Performance 

& Electrical  

Rated Voltage 

208-230V AC / 1 PH 

208-230V AC / 1 PH 

208-230V AC / 1 PH 

Control 

Remote (standard) or 

Wall (optional) 

Remote (standard) or 

Wall (optional) 

Remote (standard) or 

Wall (optional) 

Setting Range 

61°F to 86°F 

61°F to 86°F 

61°F to 86°F 

  Cooling Capacity (BTU/H) 

12000 

14400 

22800 

Heating Capacity (BTU/H) 

13000 

16000 

27400 

Wire Size / No. of Conductors 

4C- 14 AWG 

(Recommended) 

4C- 14 AWG 

(Recommended) 

4C- 14 AWG 

(Recommended) 

Indoor Air Circulation (CFM)                                  

(High Fan Speed) 

353 

353 

694 

Dehumidifying Volume(pts/h) 

2.96 

3.8 

5.28 

FAN Motor 

Fan Motor Speed (RPM)                                                         

(SH / H / M / L / SL ) 

845 / 700 / 530 / 600 / 515 

845 / 700 / 530 / 600 / 515 

620 / 570 / 520 / 280  

Output of Fan Motor (W) 

11 

11 

50 

Fan Motor Capacitor (ufd) 

Fan Motor RLA ( A) 

0.23 

0.23 

0.43 

Fan Type 

Centrifugal 

Centrifugal 

Centrifugal 

Diameter-Height (in) 

11.14 

– 5.83 

11.14 

– 5.83 

17.72 

– 4.41 

Evaporator 

Evaporator 

Aluminum fin - Inner 

Grooved copper tube 

Aluminum fin - Inner 

Grooved copper tube 

Aluminum fin - Inner 

Grooved copper tube 

Pipe Diameter (in) 

0.375 

0.375 

0.28 

Row-Fin Gap (in) 

2-0.06 

2-0.06 

3-0.05 

Coil length(L) x height(H) x coil 

width(W) (in) 

37.64 x 8.0 x 1.5 

37.64 x 8.0 x 1.5 

80.35 x 6.75 x 1.18 

Design Data 

Swing Motor Model                                         

(for horizontal louver) 

MP35EA 

MP35EA 

MP35EA 

Fuse(A) 

3.15 

3.15 

3.15 

High Pressure (PSI) 

550 

550 

550 

Low Pressure (PSI) 

240 

240 

240 

Auto Restart 

Yes 

Yes 

Yes 

Condensate Pump 

Yes 

Yes 

Yes 

Condensate Pump lift (ft) 

2.3 

2.3 

3.6 

Anti-Mildew Protection 

Yes 

Yes 

Yes 

Sound Pressure Level dB(A)                         

(High Fan Speed) 

46 

46 

39 

Sound Power Level dB(A)                       

(High Fan Speed) 

56 

56 

49 

Flare Liquid line 

1/4"  

1/4"  

 3/8" 

Flare Suction line 

3/8" 

1/2" 

5/8"  

Dimensions 

& Weight 

Dimensions of Unit                  

(W / D / H)  (approx in) 

22.4 / 22.4 / 9.1 

22.4 / 22.4 / 9.1 

33.1 / 33.1 / 9.45 

Dimension of Package            

(W / D / H)   (approx in) 

33.5 / 28.8 / 12.8 

33.5 / 28.8 / 12.8 

37.9 / 37.9 / 12.8 

Net / Gross Weight (lb) 

39.7 / 50.7 

39.7 / 50.7 

61.7 / 77.2 

Dimensions of Panel               

(W / D / H)   (approx in) 

25.6 / 25.6 / 2.0 

25.6 / 25.6 / 2.0 

37.4 / 37.4 / 2.36 

Dimension of  Panel Package 

(W / D / H) (approx in) 

28.9 / 26.5 / 4.6 

28.9 / 26.5 / 4.6 

41.1 / 40.5 / 5.12 

Net / Gross Weight of Panel (lb) 

5.5 / 8.1 

5.5 / 8.1 

14 / 22 

 
 
 

Содержание SHE12H4ZIGB

Страница 1: ...Y SERIES MINI SPLIT FIVE PORT MULTI ZONE INSTALLATION MANUAL SMZ42H46ZOGX Condenser SHE9H4ZIGX Evaporator SHE12H4ZIGX Evaporator SHE18H4ZIGX Evaporator SHE9H4ZIGB Evaporator SHE12H4ZIGB Evaporator SHE18H4ZIGB Evaporator SHE24H4ZIGB Evaporator ...

Страница 2: ...e Cable to the Outdoor Unit Diagram 15 Connect the Cable to the Indoor Unit Diagram 16 Typical Outdoor Installation Adaptor Explanation 17 Evacuation of the System 18 Leak Testing 18 Vacuum Purge 18 Start Up Testing 20 Preparation 20 Operational Test 20 Adjust Differential 21 Outdoor Unit Specifications 22 Indoor Unit Specifications Wall Mounted A 23 Indoor Unit Specifications Wall Mounted A 24 In...

Страница 3: ...the systems oil quickly absorbs moisture and will contaminate and damage the system To prevent mixing of refrigerant or refrigeration lubricating oil the sizes of connecting sections of charging port on main unit and installation tools are different from those used for the conventional refrigerant units Accordingly special tools are required for the new refrigerant R410A units The best and recomme...

Страница 4: ...cluded parts and connecting for above indoor units please refer to the manual to be included with each indoor unit INSTALLER SUPPLIED PARTS The following additional Items are required for proper installation Refrigerant line set Insulated copper tubing o 9K Indoor 1 4 liquid line and 3 8 suction line o 12K Indoor 1 4 liquid line and 1 2 suction line for SHE12H4ZIGX 1 4 liquid line and 3 8 suction ...

Страница 5: ...TALLATION CONSIDERATIONS General Information Application Check the application of the unit prior to installation Certain applications require additional components or installation parameters Computer or Data Server Rooms These require approximately 12 000 BTU H capacities per 250 ft of room size Based on 8 ceiling height Unit has low ambient controller Offices and Commercial Spaces Churches etc Th...

Страница 6: ...GX SMZFC18H4ZIGX SMZFC24H4ZIGX Ducted Indoor Unit SMZD9H4ZIGX SMZD12H4ZIGX SMZD18H4ZIGX SMZD21H4ZIGX SMZD24H4ZIGX 2 INDOOR UNITS 3 INDOOR UNITS 4 INDOOR UNITS 5 INDOOR UNITS 9K 9K 9K 12K 9K 18K 12K 12K 12K 18K 18K 18K 12K 21K 12K 24K 18K 21K 18K 24K 21K 21K 21K 24K 9K 9K 9K 9K 9K 12K 9K 9K 18K 9K 12K 12K 9K 12K 18K 9K 18K 18K 12K 12K 12K 12K 12K 18K 12K 18K 18K 9K 9K 21K 9K 9K 24K 9K 18K 21K 9K 12...

Страница 7: ... best location for mounting the outdoor unit Ensure the dimensions requirement indicated be the arrows are followed 2 Do not mount this unit close to combustibles or heat sources 3 Although this unit is fairly quiet when in operation do not mount where noise issues could be a problem Line set length Locate the Indoor and Outdoor units as close together as possible Line set height cannot exceed spe...

Страница 8: ...near hazardous chemicals or combustible gases 2 Mounting the Wall Plate After determining an acceptable location for the indoor unit fasten the wall bracket securely to the wall using the proper anchors installer supplied Be sure the wall bracket is level and firm to the wall using a minimum of 4 screws or wall anchors Failure to mount the wall bracket level can result in improper condensation dra...

Страница 9: ...r the bottom portion of the indoor unit towards the wall snapping it into the clips at the bottom of the unit See Figure 4 If using the left rear exit run lines from outside to indoor unit Form line set to mate to indoor unit stubs and connect prior to mounting to indoor unit If necessary run lines along inside wall and carefully remove the proper cut out from the indoor unit housing Line sets may...

Страница 10: ...ON Outdoor unit dimension 3 17 7 3 9 40 43 4 42 8 7 5 24 8 17 3 15 8 14 3 4 8 Outdoor unit location The location must allow easy servicing and provide good air circulation as shown in the illustration below 20 40 79 20 20 20 79 Figure 8 Figure 7 Top View Side View ...

Страница 11: ...purpose Follow mounting instructions for bracket to ensure safe installation Anchor bolts of the proper size and type Installer provided must be used For best results mount this unit as close as possible to the evaporators Check maximum line length below before mounting Maximum Line length and height b a e d c L4 L3 L2 L5 L1 Outdoorunit Height difference between indoor unit and outdoor unit H1 Hei...

Страница 12: ... the mounting location Pad Wall Brackets etc route the line sets from the Indoor unit to the outdoor unit and secure with clamps or Plastic Duct as required Installation Notes This unit is designed to run two three four or five indoor units DO NOT use this system with one indoor unit See page 7 The outdoor unit is supplied with a sufficient refrigerant charge of R410A for a maximum Design Length n...

Страница 13: ...ther Be sure to leave ample length on control cable to allow for termination Bundle can be secured together using vinyl tape Note Condensation drain MUST be placed at the bottom of the bundle as shown in the Figure 14 Failure to do so may cause evaporator to drain improperly 7 Line sets must have each tube insulated separately including their unions with at least 1 4 thick insulation Wrap the refr...

Страница 14: ...he control cables according to the diagrams on page 15 Make power connections per diagram on page 15 Remove the handle on the right side of the outdoor unit Remove panel on the right front Remove the cable clamp and connect the power connection cable to the terminal Wiring should be terminal to terminal and to correct indoor unit Do not cross wires Reattach the cable clamp Reinstall the handle Con...

Страница 15: ...venient sequence according to your installation considering line set sizes Example If installation consists of 2 9K indoor units it would be easier to use ports D and E since no adapter would be required Another example would be installation of an 2 18K indoor unit and 2 9K indoor units The best ports to use here would be B C for 18K indoor units and D E for 9Kindoor units again no adapter is requ...

Страница 16: ...o are the same as the wiring diagram Tighten terminal screws for safe connections DO NOT CROSS WIRES DO NOT CONNECT CONDENSATE PUMP TO THE INDOOR UNIT After wiring replace the electric box cover and then close the front panel by pressing the corners inward to latch Note For detailed information about other types of indoor units please refer to the manual to be placed with each indoor unit Screws C...

Страница 17: ... E since no adapter would be required Another example would be installation of an 18K indoor unit and 2 9K indoor units The best ports to use here would be B C D or E again no adapter is required Typical outdoor installation Figure 19a Figure 19c See page 12 for line set sizes and adapter requirements Figure 19d 1 4 3 8 Adaptor Figure 19b OR Intake Air Exhaust Air E E D D C C B B A A 1 4 3 8 1 4 1...

Страница 18: ...ose of the manifold valves to a vacuum pump and open fully the low and high pressure sides of the manifold valves DO NOT OPEN SERVICE PORT VALVES 2 Turn on the vacuum pump Evacuate system for about 30 minutes and confirm that the vacuum reading is 500 microns 3 Close all manifold valves and turn off the vacuum pump After waiting for several minutes confirm that the vacuum reading of the manifold h...

Страница 19: ...f the whole system Purge 150 PSI for 1 2 minutes Re tighten flare fitting Remove nitrogen tank from manifold and replace with vacuum pump Vacuum to 500 microns for 30 minutes Repeat the above steps for each connected indoor unit Figure 21b Once the vacuum operation has been performed on the system open the valve slowly to allow the flow of refrigerant Once the refrigerant flow cannot be heard open...

Страница 20: ...n the cooling mode 4 Press the FAN button to select high fan speed on all units 5 After operating for several minutes check for cool air flow Outlet temperature should be 20 to 24 º F lower than ambient temperature If outlet temperature is out of range contact technical support 6 If cooling mode is operating properly check for proper heat operation 7 Press the mode button to select HEAT see Note a...

Страница 21: ... heating and operation would flash for three times Alternately press the then button on remote three times within 5 seconds while in the heating mode with set point set to 19 The indoor unit will reset the temperature and deliver 1 1 8 F differential signal to the outdoor unit At this time 1 will display on the indoor unit LED of heating and operation would flash for three times Alternately press ...

Страница 22: ... x H x D in 39 96 x 43 43 x 17 32 Packing Dimensions W x H x D in 45 59 x 48 62 x 19 41 Net Gross Weight lb 224 9 246 9 Connection Flare Liquid line Four of 1 4 9K 12K 18K BTU One of 3 8 21K 24K BTU 1 Flare Suction line Two of 3 8 9K BTU Two of 1 2 12K 18K BTU 2 One of 5 8 21K 24K BTU 3 Service Port Fitting 1 2 20 UNF High Pressure psi 550 Low Pressure psi 240 Design Length ft 24 6 for each indoor...

Страница 23: ...050 900 1450 1250 1150 1050 1500 1150 1050 950 1500 1200 1100 1000 Output of Fan Motor W 10 10 20 Fan Motor Capacitor ufd 1 1 1 5 Fan Motor RLA A 0 17 0 17 0 32 Fan Type Cross Flow Fan Cross Flow Fan Cross Flow Fan Diameter Length in 3 35 26 34 3 35 26 34 3 86 28 86 Evaporator Evaporator Aluminum fin copper tube Aluminum fin copper tube Aluminum fin copper tube Pipe Diameter in 0 276 0 276 0 276 R...

Страница 24: ...A Fan Motor RLA A 0 2 0 2 0 32 0 24 Fan Type Cross Flow Fan Cross Flow Fan Cross Flow Fan Cross Flow Fan Diameter Length in 3 5 8 25 2 5 3 5 8 25 2 5 3 6 7 28 3 6 7 30 1 8 Evaporator Evaporator Aluminum fin copper tube Aluminum fin copper tube Aluminum fin copper tube Aluminum fin copper tube Pipe Diameter in 0 276 0 276 0 276 0 276 Row Fin Gap in 2 0 06 2 0 06 2 0 06 2 0 06 Coil length L x height...

Страница 25: ... 840 760 690 620 570 450 Output of Fan Motor W 30 30 30 Fan Motor Capacitor ufd N A N A N A Fan Motor RLA A 0 15 0 15 0 15 Fan Type Cross Flow Fan Cross Flow Fan Cross Flow Fan Diameter Length in 3 1 7 14 4 7 3 1 7 14 4 7 3 1 7 14 4 7 Evaporator Evaporator Aluminum fin copper tube Aluminum fin copper tube Aluminum fin copper tube Pipe Diameter in 1 4 1 4 1 4 Row Fin Gap in 2 0 05 2 0 05 2 0 05 Coi...

Страница 26: ...4 41 Evaporator Evaporator Aluminum fin Inner Grooved copper tube Aluminum fin Inner Grooved copper tube Aluminum fin Inner Grooved copper tube Pipe Diameter in 0 375 0 375 0 28 Row Fin Gap in 2 0 06 2 0 06 3 0 05 Coil length L x height H x coil width W in 37 64 x 8 0 x 1 5 37 64 x 8 0 x 1 5 80 35 x 6 75 x 1 18 Design Data Swing Motor Model for horizontal louver MP35EA MP35EA MP35EA Fuse A 3 15 3 ...

Страница 27: ...1 1 2 5 2 Fan Motor RLA A 0 28 0 28 0 56 0 63 Fan Type Centrifugal Centrifugal Centrifugal Centrifugal Diameter Height in 5 49 4 13 5 49 4 13 5 49 4 13 5 49 4 13 Evaporator Evaporator Aluminum fin Inner Grooved copper tube Aluminum fin Inner Grooved copper tube Aluminum fin Inner Grooved copper tube Aluminum fin Inner Grooved copper tube Pipe Diameter in 0 28 0 28 0 28 0 28 Row Fin Gap in 2 0 06 2...

Страница 28: ...49 75 Fan Motor Capacitor ufd 1 5 3 3 Fan Motor RLA A 0 35 0 35 0 43 Fan Type Centrifugal Centrifugal Centrifugal Fan Quantity 2 2 3 Diameter Length in 5 49 5 30 5 49 5 30 5 49 5 30 Evaporator Evaporator Aluminum fin Inner Grooved copper tube Aluminum fin Inner Grooved copper tube Aluminum fin Inner Grooved copper tube Pipe Diameter in 0 28 0 28 0 28 Row Fin Gap in 2 0 06 3 0 06 3 0 06 Coil length...

Страница 29: ...f Fan Motor W 22 5 22 5 Fan Motor Capacitor ufd 3 3 Fan Motor RLA A 0 54 0 54 Fan Type Centrifugal Centrifugal Fan Quantity 4 4 Diameter Length in 5 49 5 30 5 49 5 30 Evaporator Evaporator Aluminum fin Inner Grooved copper tube Aluminum fin Inner Grooved copper tube Pipe Diameter in 0 28 0 28 Row Fin Gap in 3 0 06 3 0 06 Coil length L x height H x coil width W in 36 4 x 8 3 x 1 5 36 4 x 8 3 x 1 5 ...

Страница 30: ...receiving range Is it obstructed Replace the batteries Is remote control damaged Water leaking into room The air humidity is excessively high Check to see if all windows and doors are closed Call service Tech if not corrected by the above action Water leakage in outdoor unit When the unit is running in Auto Defrosting mode ice will thaw and drip into pan When the unit is running in HEAT mode the w...

Страница 31: ...TICS Symbol Explanation Symbol Color Symbol Color Symbol Past Name WH WHITE GN GREEN SAT OVERLOAD YE YELLOW BN BROWN COMP COMPRESSOR RD RED BU BLUE PROTECTIVE EARTH YEGN YELLOW GREEN BK BLACK VT VIOLET OG ORANGE Wiring Diagram for SMZ42H46ZOGX P P A B C E P ...

Страница 32: ...OOR PC BOARD There is a LED display for error codes that is located on the outdoor main board Remove the top cover of the outdoor unit to gain access to the main board in the control box LED Display JUMPER if missing from the spare part pc board remove from factory installed pc board ...

Страница 33: ...r Unit E b7 22 Flashes B7 Jumper failure C5 C5 15 Flashes C5 Trial operation dd dd Flashing Flashing Flashing dd Incorrect connection of communication wire or expansion valve failure dn dn 3 Flashes 3 Flashes 3 Flashes dn High Pressure Protection E1 E1 1 Flash E1 Anti Freezing Protection E2 E2 2 Flashes E2 Low Pressure Protection E3 E3 3 Flashes E3 Exhaust Protection Temperature Overheat E4 E4 4 F...

Страница 34: ...lling LE LE 3 Flashes 3 Flashes 3 Flashes LE Over Speed LF LF 3 Flashes 3 Flashes 3 Flashes LF IPM Reset P0 P0 3 Flashes 3 Flashes 3 Flashes P0 Compressor Over current Protection P5 P5 15 Flashes P5 Communication Error between the Drive Board and the Main Board P6 P6 16 Flashes P6 Module Temperature Sensor Failure P7 P7 18 Flashes P7 Radiator Overheat Protection P8 P8 19 Flashes P8 AC Contactor Pr...

Страница 35: ...est for heating or cooling All indoor units will stop once the outdoor unit is turned off Tubing Connection Size INDOOR unit copper tubing 1 4 3 8 1 2 5 8 Adapter Included Adapter Size Wall Mounted Indoor Unit A 9K x x Yes 1 2 F to 3 8 M 12K 18K x x Yes 3 8 F to 1 2 M Wall Mounted Indoor Unit B 9K 12K x x Yes 1 2 F to 3 8 M 18K x x Yes 3 8 F to 1 2 M 24K x x No Cassette Floor ceiling Console Ducte...

Страница 36: ...nable time after the unit is returned This warranty DOES NOT cover Damage accidental or otherwise to the unit while in possession of the consumer that is not a result of a defect in material in workmanship Damage caused by consumer misuse tampering or failure to follow all care and maintenance instructions in the manuals Damage to the finish of the case or other parts caused by water Damage caused...