TROUBLESHOOTING:

TROUBLESHOOTING:

PROBLEM

DISPLAY

SOLUTION

System is not operational 
although it is switched on.

Power switch and power LED do not 
light up.

Check mains connection.

Disconnect the system from the 
mains! Check the primary fuse of the 
system and replace it if necessary. If 
the fuse trips repeatedly, disconnect 
the system from the power mains 
and hand it over to an authorised 
service centre.

Power switch, ON LED and Protect LED 
light up.

System is overloaded. Reduce volume. 
Protect LED goes out after a short 
time; the system is operational again.

Protect LED remains lit even after 
reduction of the volume.

Internal fault. Turn off the system, 
disconnect it from the power mains, 
and hand it over to an authorised 
service centre.

Microphone signal distorted.

Reduce the microphone channel 
volume and increase the overall 
volume (Main Level). Reduce the 
volume of any additionally connected 
audio source (e.g., keyboard) by the 
same amount.

Guitar/MP3 signal distorted.

Reduce the guitar/MP3 channel volume 
and increase the overall volume (Main 
Level). Reduce the volume of any 
additionally connected audio source 
(e.g., keyboard, microphone) by the 
same amount.

Reduce the volume of the audio 
source (e.g., guitar, MP3 player) and 
increase the channel and/or overall 
volume.

Signal from line input 
distorted.

Reduce the line channel volume and 
increase the overall volume (Main 
Level). Reduce the volume of any 
additionally connected audio source 
(e.g., keyboard, microphone) by the 
same amount.

Reduce the volume of the audio 
source (e.g., mixer increase the 
channel and/or overall volume.

Overall signal distorted.

Limit LED is always on.

Reduce overall volume (MAIN LEVEL).

Содержание M-A5

Страница 1: ...A5 ALL IN ONE ARRAY SYSTEM Designed in Germany 2014 7 www se audiotechnik com Hot line 400 109 1122 Web www se audiotechnik com E mail sales se audiotechnik com Asia Pacific Sales Center USER S MANUA...

Страница 2: ...ars Therefore guarantees for high quality products with its name and many years of experience as a producer Please take a few moments to read these instructions carefully as we want you to enjoy your...

Страница 3: ...cing instructions in the literature accompanying the appliance CAUTION HIGH VOLUME You will operate this transmission system for professional use Therefore the commercial use of this equipment is liab...

Страница 4: ...t in order toavoid loud popping sounds when the connected devices are turned on and off CONNECTIONAND OPERATION It is possible to set both the overall system volume as well as the volume of the subwoo...

Страница 5: ...NE INPUT LEFT RIGHT UNBALANCED Unbalanced line input RCA for connecting an external audio source e g laptop 5 LINE INPUT LEFT RIGHT BALANCED Balanced line input XLR 6 3 mm jack combo for connection of...

Страница 6: ...ipping range Brief flashing is not a cause for concern since the internal audio limiter compensates for over modulation Permanent illumination should be avoided by reducing the volume PROTECT Lights u...

Страница 7: ...service centre Microphone signal distorted Reduce the microphone channel volume and increase the overall volume Main Level Reduce the volume of any additionally connected audio source e g keyboard by...

Страница 8: ...nector M A5 40 Hz 20 kHz 126 dB 120 2 8 40 OZ Ferrite magnet 2 voice 16 3 Neodymium magnet 1 voice coil 1 1 N42H Neodymium magnet phenolic diaphragm 1 voice coil Class D amplifier SMPS DSP 48 kHz 24 b...

Страница 9: ...warranty is expressly limited of the possibility of a is not liable for any dam branded hardware product fails to work as warranted above your sole and exclusive remedy LIMITATION OF LIABILITY If you...

Страница 10: ...centre for such equipment This will help to protect the environment in which we all live BATTERIES AND ACCUMULATORS The supplied batteries or rechargeable batteries can be recycled Please dispose of...

Отзывы: