SE Audiotechnik I-Line Series Скачать руководство пользователя страница 15

IA 202D / IA 402D Instruction Manual 

 

 

 

Revision 3 

15 

 

The names of the presets are organized in such a way that first five symbols would 

always represent loudspeaker model for which the preset is made. This is due to the safety 

reason so that user always knows if his user preset has the right factory settings. 

 

Factory  presets  are  each  speaker  systems  default  configuration  with  factory  pre-

defined filter & limiter settings layer. User presets are being built on top of factory presets by 

saving additional user adjustment layer containing: 

 

 

User HP filter settings 

 

User EQ settings 

 

User Delay settings 

 

6.3.3.1.1.

 

Preset Loading 

To load a preset scroll to the chosen preset and click the rotary controller. A dialogue 

is displayed on the screen to either load preset, save preset or go back. Saving is only available 

in user preset area to save user presets. 

 

By  pressing 

Load  Preset

  the  preset  is  loaded  in  the  DSP  and  “Preset  Loaded!”  is 

displayed shortly on the screen. 

 

To return choose 

Back

 and click the rotary controller. 

 

 

Figure 10. Preset Loading. 

6.3.3.1.2.

 

Preset Saving 

To save a preset choose one of the existing or empty user preset locations and click 

the rotary controller. A dialogue similar to factory preset loading is displayed on the screen, 

only in this case an additional option is available to save the preset. 

 

 

Figure 11. Preset Loading & Saving. 

By click on 

Save Preset

 a dialogue to enter preset name is displayed.  

Here user can edit last 9 symbols to write a note or name for the user preset. To edit 

the name click on the name with rotary controller. Character selection is done by scrolling the 

controller and choosing the letter by clicking. Character deletion is performed by choosing 
the 

 symbol and clicking. To complete the editing of the name choose space symbol and 

click twice. 

To  confirm  preset  saving  choose 

Save

  and  click  the  rotary  controller.  Saving  is 

confirmed with a display on the screen “Preset Saved!” 

 

   FACTORY PRESET   

  IC 34: DEFAULT    
  Back
> Load Preset  

     USER PRESET    
      EMPTY: USER 1 

  Back

  Load Preset  
> Save Preset

Содержание I-Line Series

Страница 1: ...IA 202D IA 402D Instruction Manual I Line Elegant installation speaker systems Elegant installation speaker systems Firmware version 1 0 Revision 3 0...

Страница 2: ...documentation such as this instruction manual When reselling this product hand over this manual to the new owner If you supply SE Audiotechnik products please draw the attention of your customers to...

Страница 3: ...ding 15 6 3 3 1 2 Preset Saving 15 6 3 3 1 3 Preset Information 16 6 3 3 2 Input Level 16 6 3 3 3 HP LP Filter 17 6 3 3 4 Phase Inversion 17 6 3 3 5 Equalizers EQ 1 to EQ 5 17 6 3 3 6 Delay 18 6 3 3 7...

Страница 4: ...96 EC and Directive 2003 108 EC of the European Parliament on waste electrical and electronic equipment WEEE Main Electrical Safety Precautions THE MAINS PLUG OF THE POWER SUPPLY CORD MUST REMAIN REA...

Страница 5: ...the grounding type plug A grounding type plug has two blades and a third grounding prong The third prong is provided for your safety If the provided plug does not fit into your outlet consult an elec...

Страница 6: ...mation 2 1 Features Both system amplifiers are equipped with a simple to use LCD screen and rotary knob controller in a simple and unobtrusive aluminum housing Both amplifiers have both Phoenix and SP...

Страница 7: ...er Phase Invert Mute Output Gain Controls Digital encoder with push button Maximum Input Level 20dBu Signal Connectors XLR 3 pin male line level inputs link outputs Phoenix Contact MSTB 3 pin inputs l...

Страница 8: ...D IA 402D Instruction Manual Revision 3 8 3 Overview 3 1 Front Panel 1 2 3 4 5 1 Alpha numeric LCD screen 2 Master Control rotary encoder with push button 3 Power switch 4 Air intake fan 5 Air intake...

Страница 9: ...ru Channel A XLR Male 14 Input Channel B Euroblock Phoenix 15 Link Thru Channel B Euroblock Phoenix 16 Input Channel A Euroblock Phoenix 17 Link Thru Channel A Euroblock Phoenix 1 AC power connector 2...

Страница 10: ...ik dealer or SE Audiotechnik support center for help and assistance We recommend that you save all packing materials and full package contents if you ever need to transport the amplifier This also inc...

Страница 11: ...ower until the condensation has completely dried out Rapidly turning the unit on and off in succession can cause it to malfunction After turning the unit off wait for more than five seconds before tur...

Страница 12: ...t Routing mode is shown When clipping occurs the level is replaced with INPUT CLIP text and the backlight of the amplifier blinks thus calling for user attention Further actions from the Overview scre...

Страница 13: ...ngs menu is shown in Figure 5 Figure 5 DSP Settings menu 6 3 1 Input Sensitivity Input Sensitivity menu allows user to change amplifier s reference sensitivity Two options are available Pro Audio refe...

Страница 14: ...ivided in two basic types Factory presets Marked with an F letter at the right side of the preset name User presets Marked with an U letter at the right side of the preset name Currently loaded preset...

Страница 15: ...Preset Loaded is displayed shortly on the screen To return choose Back and click the rotary controller Figure 10 Preset Loading 6 3 3 1 2 Preset Saving To save a preset choose one of the existing or...

Страница 16: ...hen the level is equal to 24 12 6 3 and 1 dBFS a corresponding level threshold is displayed To avoid input clipping set your levels depending on the program material and leave the headroom of at least...

Страница 17: ...Two settings are available Normal In phase setting Inverted In this setting phase polarity is inverted 180 phase shift for all frequencies 6 3 3 5 Equalizers EQ 1 to EQ 5 Each of IA 202D IA 402D ampli...

Страница 18: ...delay of 2 samples For more information about delay settings please refer to section 6 3 5 Delay Settings Figure 18 Channel Delay Menu In chosen channels Delay menu user can see and adjust the delay...

Страница 19: ...4 2 Load Preset In a similar way as presets are managed and loaded for individual channels Load Preset enables user to load the same preset in both channels at once Currently only Loading of both chan...

Страница 20: ...es 2 samples minimum latency Only one channel can have this configuration The other one is bypassed Delay Settings menu allows to change delay settings for each channel The delay values are displayed...

Страница 21: ...On selection of this setting a dialogue appears where the timeout can be set with a maximum value of 60 seconds Always On which sets the backlight to be always on Figure 24 LCD Backlight Menu 6 4 2 L...

Страница 22: ...used by service personnel only Figure 28 Firmware Update Menu 6 4 6 Lock In the Screen lock menu user can set automatic screen locking settings Automatic Lock Will lock the amplifier screen after a se...

Страница 23: ...further operation 7 2 Quick Output Level Change If the amplifier is in the Overview screen and is unlocked turning the rotary encoder will act as a Quick Level Change or Master Level control This all...

Страница 24: ...Preset EQ Polarity Inversion Polarity Inversion Delay Delay RMS Peak Limiters RMS Peak Limiters PHOENIX SPEAKON CH A B PHOENIX SPEAKON CH A PHOENIX SPEAKON CH B AMP CH A AMP CH B 1 1 2 2 1 1 2 2 1 1 2...

Страница 25: ...oth Channels Delay Settings Exit Back Back LCD Backlight LCD Brightness Reset HW Information Firmware update Lock Exit Back Preset Input Level HP LP Filter Phase Inversion EQ 1 Low Shelf EQ 2 Parametr...

Страница 26: ...IA 202D IA 402D Instruction Manual Revision 3 26 10 Mechanical Dimensions 483 66 230 4 252 4 264 7 54 22...

Страница 27: ...SE Audiotechnik 2018...

Отзывы: