中文
EN
D
U-BR
ACKET A
CCES
SOR
Y
17
16
Figure 11.
Bracket mounting steps.
Figure 12.
A
CV 212
hung from a truss structure using half coupler/s both with
one (left) and two (right) pick points of the
CV 212 UB
U-bracket.
5. Make sure the silicon washer is placed on the side of the cabinet, and that the metal washer is on the
side of the handle screw.
6. Place the U-bracket vertically, matching the attaching holes in the center arm.
7. Fully and securely tighten the handle screws at the flying points to hold the U-bracket in place before
making the final installation.
Please note that the handle of the handle screws can be rotated in order to find the most suitable position
for tightening and loosening the screw. Furthermore, after the installation, both handles can be equally
orientated to give the assembly a nicer appearance. To do this, simply:
1.
Pull the handle of
the handle screw.
2.
Rotate it to the desired position.
3.
Release the handle
to fix it in place.
Before performing any installation procedure, always:
-
Adhere to and respect any local regulation regarding manipulation and hoisting
of heavy loads.
-
Calculate the total suspended loads and guarantee that all components involved
will be used within their respective mechanical limits.
-
Validate and approve all installation calculations and designs with a professional
licensed in Structural or Mechanical Engineering.
-
Make sure the fixation points and elements in the ceiling and/or structure resist
loads at least 10 times greater than the weight of the unit.
-
Verify that all the elements and components are in optimal conditions before performing
the attachment. In addition, make sure all of these are safe and correctly used.
-
Ensure that only qualified and experienced personnel carry out the installation.
-
Establish at least one independent safety attachment in addition to the main one,
foreseeing the failure of the later.
The
CV 212 UB
can be hung at one or two points, using the M10 holes in the centre arm. The unit can be
hung directly from a truss structure using the proper adapter/s, like half coupler clamp/s for example.
INSTALLATION