中文
EN
D
LCD PL
ATE AMPLIFIER
27
26
DSP SETTINGS > BYPASS USER EQ
In order compare the response of the subwoofer with and without the applied EQ, this section allows to
bypass all user EQs with a single click.
BYPASS USER EQ
Back
Bypass a l l +
Enable a l l
Figure 23.
Bypass User EQ menu.
Remember that user EQs are bypassed by default and can be activated individually.
DSP SETTINGS > DELAY
The
Delay
section allows the user to apply a delay to the signal, visualise it in different units and
determine the total delay. This screen has the following three sections:
-
User added delay
: This is the delay defined or added by the user depending on the specific needs
of his application.
-
Preset delay
: Depending on the preset enabled or selected, the system may include an additional
delay. This delay is added by the current preset and for some factory presets, it can be also edited.
-
Total DSP delay
: Total sum of "
User
", "
Preset
" and internal DSP latency. It is not an editable
parameter and is only shown for information and reference.
The "
User
" and "
Preset
" delays can be defined in three different units, corresponding to the editable
parameters in the first two delay sections:
-
Samples
: for 48 kHz sampling rate.
-
Time
: Delay in milliseconds (ms), referred to the 48 kHz sampling rate.
-
Distance
: Delay in meters (m), referred to
c
= 343 m/s.
When changing a parameter in any section, all the other parameters are updated with the corresponding
value in their units.
Figure 24.
Delay menu.
DELAY
Back
User added delay:
> Bypass: OFF
Samples: 0
Time: 0.00 ms
Distance: 0.00 m
Preset delay:
Bypass: OFF:
Samples: 10
Time: 0.21 ms
Distance: 0.07 m
Total DSP delay:
Samples: 63
Time: 1.31 ms
Distance: 0.45 m
The minimum "
User
" delay available for the
B 15A
subwoofer is 1,297 samples, that corresponds to
27 ms and approximately 9.3 meters of propagation delay. Depending on the factory preset selected,
the maximum available is 1,380 samples, equivalent to 28.8 ms and 9.9 meters.
DSP SETTINGS > RESET USER PARAMS
The
Reset User Params
submenu allows to reset user DSP settings such as:
-
High-pass filter
-
Low-pass filter
-
Equalizers
-
Delay
-
Phase Inversion
-
Bypass user EQ
The Output Gain, Input Sensitivity and the Preset selected are not affected by this function.
Reset User
Parameters?
(DLY, EQ, Filter, PHA))
Back
> Reset
Figure 25.
Reset user parameters menu.
By turning the controller the options "
Reset
" or "
Back
" will appear. By choosing the first one, the message
"
Reset Done
" is shortly displayed on the screen. To return to the DSP Settings, choose "
Back
".