3.3.
Special features of automatic mode
Pressing the "STOP" button when the external command is active ("AUT" pictogram flashing) will stop the generating set
immediately in general fault mode,
(
the general fault LED will light up flashing and the following message will appear:
means S.O.S.
000
010
represents a fault code
Refer to the list of fault codes in
Section 4.4.
3.4.
Emergency stop
Pressing the emergency stop button switches off the generating set immediately.
The LED lights up red and remains lit, the LED flashes and the following screen appears:
This screen displays the SOS message and the emergency stop
fault code (also see section 4.4).
To restart, it is necessary to:
n
resolve the fault which has required the emergency stop button to be pressed
o
release the emergency stop button by turning it clockwise
p
acknowledge (reset) the fault by moving the key switch to OFF, waiting for the "ON" LED to go out completely and then
moving the key switch to ON.
Note:
Once you have set the key switch to "OFF", if you do not wait for the "ON" LED to go out completely, the fault will not be
acknowledged on restarting.