FEATURES 

 

High Performance Mobile DMX Scanner with 1 60W LED Source 

 

7  White 

 

7 Rotating Gobos + Open 

 

9 DMX Channels 

 

3- Button Menu System with LED Display 

 

3 Operating Modes: DMX, Master/Slave, Sound Active 

 

Sound Sensitivity Knob and microphone 

 

Built in Lighting Programs 

 

Manual Focusing Lens 

 

Gobo Shake effect 

 

Strobe effect in every color 

 

13-degree beam angle 

 

Dual-Fan cooled 

 

Hanging Bracket Included 

 

Safety Rope Eyelet 

 
3. SETUP 

To run light shows you can use a DMX-512 controller or run shows on two or 
more fixtures set to master/slave operating mode. The combined number of 

channels required by all the fixtures on a link determines the number of 
fixtures that can be supported. 

Fixtures on a DMX link must be daisy chained in one single line. Connecting 
more than 32 fixtures may result in deterioration of the digital DMX signal. 
The maximum recommended cable-run distance is 1640 ft. 

The maximum recommended number of fixtures on a single link is 32. 
To link fixtures together you’ll need DMX cables. You should always use data 

grade cables that can carry a high quality signal and are less prone to 
interference. 

Standard microphone XLR cables will work, but are not designed for data 
transmission, and could cause continuity issues. 

OVERHEAD RIGGING requires extensive experience, including calculating 
working load limits, installation material being used, and periodic safety 

inspection of all installation material and the device. If you lack these 
qualifications do not attempt the installation yourself, but instead use a 
professional structural rigger. 
Before rigging make sure the installation area can hold a minimum point 

load of 10 times the device’s weight. Mount the device using an appropriate 
clamp and always install a safety-rope that can hold at least 12 times the 
weight of the fixture. 

 
 

 

Содержание Sixty Scan

Страница 1: ...door use only To prevent risk of fire or shock do not expose fixture to rain or moisture Make sure there are no flammable materials close to the unit while operating ALWAYS disconnect from the power source before replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT operate a...

Страница 2: ...32 fixtures may result in deterioration of the digital DMX signal The maximum recommended cable run distance is 1640 ft The maximum recommended number of fixtures on a single link is 32 To link fixtures together you ll need DMX cables You should always use data grade cables that can carry a high quality signal and are less prone to interference Standard microphone XLR cables will work but are not ...

Страница 3: ... d 2 for slow room scan d 3 for use with a remote sold separately The master unit must be the first unit Finally chain the units together using DMX cable 3 Select slave units by using the UP DOWN keys to reach S 1 in the Slave menu for identical movement S 2 for reverse pan S 3 for reverse pan and tilt S 4 for reverse tilt and they will react with the Master DMX Mode The Sixty Scan will automatica...

Страница 4: ...s DMX Channels Channel 1 Pan Horizontal Movement Value 0 255 128 Center Gradual mirror adjustment from left to right Channel 2 Tilt Vertical Movement Value 0 255 128 Center Gradual mirror adjustment from up to down Channel 3 Color Value Color 0 15 White Open 16 31 Dark Blue 32 47 Orange 48 63 Yellow 64 79 Pink 80 95 Light Blue 96 111 Green 112 127 Magenta 128 255 Rainbow Effect Slow Fast Channel 4...

Страница 5: ...otation Slow Fast 136 255 Counter Clockwise Gobo Rotation Fast Slow Channel 6 Shutter Strobe Value Feature 0 7 Blackout 8 15 Shutter Open 16 131 Strobe Slow Fast 132 139 Shutter Open 140 180 Shutter Slow Open Fast Close 181 189 Shutter Open 190 231 Shutter Fast Open Slow Close 232 239 Reset 240 247 Random Strobe 248 255 Shutter Open Channel 7 Dimmer Value 0 255 Dimmer Control 0 100 Channel 8 Built...

Страница 6: ... in a case to minimize wear and tear Returns Like any complex piece of equipment designed and built by humans manufacturing errors can cause a problem If you find yourself with a fixture that isn t behaving like it should you ll need to obtain a Return Merchandise Authorization RMA Just send an email to support sdelighting com and we ll issue you an RMA Then you ll need to send the unit to us usin...

Страница 7: ...A 125V Power Consumption 90W Light Source LED 1 x 60w White LED 50k Hours Optical Beam Angle 13 degrees Luminous Intensity 9 200 Lux 1m Thermal Max Operating Temp 113 degrees F 45 degrees C Control Protocol DMX 512 DMX Channels 9 Input 3 pin XLR Male Output 3 pin XLR Female Other Operating Modes Standalone Master Slave Sound Active Warranty 1 year limited warranty does not cover malfunction caused...

Отзывы: