![SDE Lighting Sixty Scan Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/sde-lighting/sixty-scan/sixty-scan_manual_1220358002.webp)
2
SDE Lighting –
www.sdelighting.com
– Sixty Scan
2. The Sixty Scan
FEATURES
High Performance Mobile DMX Scanner with 1 60W LED Source
7 White
7 Rotating Gobos + Open
9 DMX Channels
3- Button Menu System with LED Display
3 Operating Modes: DMX, Master/Slave, Sound Active
Sound Sensitivity Knob and microphone
Built in Lighting Programs
Manual Focusing Lens
Gobo Shake effect
Strobe effect in every color
13-degree beam angle
Dual-Fan cooled
Hanging Bracket Included
Safety Rope Eyelet
3. SETUP
To run light shows you can use a DMX-512 controller or run shows on two or
more fixtures set to master/slave operating mode. The combined number of
channels required by all the fixtures on a link determines the number of
fixtures that can be supported.
Fixtures on a DMX link must be daisy chained in one single line. Connecting
more than 32 fixtures may result in deterioration of the digital DMX signal.
The maximum recommended cable-run distance is 1640 ft.
The maximum recommended number of fixtures on a single link is 32.
To link fixtures together you’ll need DMX cables. You should always use data
grade cables that can carry a high quality signal and are less prone to
interference.
Standard microphone XLR cables will work, but are not designed for data
transmission, and could cause continuity issues.
OVERHEAD RIGGING requires extensive experience, including calculating
working load limits, installation material being used, and periodic safety
inspection of all installation material and the device. If you lack these
qualifications do not attempt the installation yourself, but instead use a
professional structural rigger.
Before rigging make sure the installation area can hold a minimum point
load of 10 times the device’s weight. Mount the device using an appropriate
clamp and always install a safety-rope that can hold at least 12 times the
weight of the fixture.