background image

Beep Sounds During Auxiliary Relay

Default: No

Selects whether or not the keypad beeps during Auxiliary Relay 
activation.

Press: 42 # 

Sound

#  

Sound=1 for Yes, =0 for No

Beep Sounds During Output #3

Default: No

Selects whether or not the keypad beeps during Output #3 
activation.

Press: 43 # 

Sound

#  

Sound=1 for Yes, =0 for No

Beep Sounds During Output #4 

Default: No

Selects whether or not the keypad beeps during Output #4 
activation.

Press: 44 # 

Sound

#  

Sound=1 for Yes, =0 for No

Anti-Pass Back Time

Default: No Anti-Pass Back

Sets the length of time an entry code will not function after it is 
used.

Press: 51 # Minutes #  

Minutes=Time in minutes (2-4), 0=No Anti-passback

RESETTING KEYPAD

Master Reset

CAUTION:  Performing a master reset will clear the 
entire memory of the 920P and return all programmable 
options to the factory default values.  ALL ENTRY 
CODES WILL BE ERASED. NOTE:  The Master Code will 
NOT be reset.

STEP 1

Disconnect power from the keypad.

STEP 2

Press and hold down the * and # keys.

STEP 3

Apply power to the keypad, continue holding the keys 
down until the red indicator starts flashing

STEP 4

Release the keys.  The red and yellow indicators will 
remain lit until the process is complete, then the 
yellow indicator will go out.

Resetting the Master Code

STEP 1

Remove the 920P from the wall and disconnect 
power from the keypad.

STEP 2 

Locate & Remove jumper at JP2.  Reference page 2.  

STEP 3

Re-apply power.  You will get a single beep and 
the yellow LED will flash momentarily.

STEP 4

Replace jumper on JP2.

THE MASTER PROGRAMMING CODE IS NOW 123456.

Beep Sounds During Main Relay

Default:  No

Selects whether or not the keypad beeps during Main Relay 
activation.

Press: 41 # 

Sound

#  

Sound=1 for Yes, =0 for No

Solid-state Output #4 On-time

Default:  02 Seconds

Sets the length of time Output #4 activates when triggered.

Press: 24 # 

Seconds

#  

Seconds=Output time in seconds (1-60), 99=Toggle Mode

Beep Sounds on Keystrokes

Default:  Yes

Selects whether or not the keypad beeps as each key is pressed.

Press: 40 # 

Sound

#  

Sound=1 for Yes, =0 for No

P:\INSTALLATION INST\Access Controls\INST-920\INST-920P.vsd     Rev G     01-18     Page 6

Selects mode for Keypad LED Backlight

Default: 30 Seconds

Selects whether or not the keypad back light stays OFF, lights for 30 
seconds when activated or stays ON.

Press: 52 # Output #  

0 = Light always OFF

1 = 30 sec light when activated (default)

2 = Light always ON 

Solid-state Output #3 On-time

Default:  02 Seconds

Sets the length of time Output #3 activates when triggered.

Press: 23 # 

Seconds

#  

Seconds=Output time in seconds (1-60), 99=Toggle Mode

Beep Sounds Anti-Tamper Activation 

Default: No

Selects whether or not the keypad beeps during Anti-Tamper 
switch activation.

Press: 45 # 

Sound

#  

Sound=1 for Yes, =0 for No

Changing the Beeper Sound Level

The Keypad’s beeper can be set to high or low level.
Remove jumper JP1 to reduce beeper sound level.

Changing the 6-Digit Master Programming Code

Press: 98 # 

Master Code

Master Code

#  

Master Code=The new 6-digit Master Programming Code

Keypad Lockout Count

Default: 3 Attempts

Sets the number or incorrect entry code attempts allowed 
before the keypad “locks out” for 60 seconds.

Press: 50 # Attempts #  

Attempts=Number of attempts before lockout (2-7)

*Refer to Option 13 to Enable Lockout Feature

Door Ajar Timer

Default:  60 Seconds

Sets the amount of time the door may be held open after an 
authorized access.  The DOOR AJAR output will activate after the 
time expires.

Press: 25 # 

Seconds

#  

Seconds=Held open time in seconds (1-60)

Содержание 920P EntryCheck

Страница 1: ...ide codeless activation of the Main Relay Auxiliary Relay Output 3 or Output 4 programmable The ALARM SHUNT signal is available when access is granted This signal can be programmed to activate any of...

Страница 2: ...ramming mode default master code Step 2 Enter 01 003 2580 2580 1 Assign User 003 with a PIN code of 2580 Activate the main relay when entered Step 3 Repeat Step 2 to enter another unique user PIN or c...

Страница 3: ...er earth ground Connect the green earth ground wire to a good earth grounding point Suggested wiring size is 18 AWG for earth ground Sense Input RE Note The SENSE input gray wire can be programmed as...

Страница 4: ...open Relay 2 toggled The yellow indicator will flash quickly while the 920P stores the new user information in memory The green indicator will light when the new code and card are accepted If the use...

Страница 5: ...larm Shunt Output Default No Output Sets which output activates during the time access is granted Use this output ot shunt alarm contacts attached to the access door This output may be timed or toggle...

Страница 6: ...ps during Main Relay activation Press 41 Sound Sound 1 for Yes 0 for No Solid state Output 4 On time Default 02 Seconds Sets the length of time Output 4 activates when triggered Press 24 Seconds Secon...

Страница 7: ...Access Controls INST 920 INST 920P vsd Rev G 01 18 Page 7 5 750 1 375 3 000 MOUNTING TO SINGLE GANG RECESSED OUTLET BOX 2X Mount at slots 4X Mount at holes With supplied screws and hole expansion anc...

Страница 8: ...P INSTALLATION INST Access Controls INST 920 INST 920P vsd Rev G 01 18 Page 8 OPTIONAL SHROUD SURFACE MOUNT WITH OPTIONAL SHROUD 4X Mount at holes POST MOUNT WITH SHROUD 4 4...

Отзывы: