background image

The 

EntryCheck

™  920P Indoor/Outdoor Keypad is a surface-mount digital 

keyless entry system designed for access control applications.  The backlit 
keys  are bright and easy-to-read. A heavy cast vandal resistant housing 
design with mounting plate allows the 920P  to be mounted on a  rugged 
surface or on a standard single-gang electrical box.  

The 920P has a capacity of 500 users. Users can be assigned to use 4 to 6 
digit  PIN codes and/or HID 125kHz proximity access credentials. An 
authenticated access can be programmed to activate one or both of the 
relay outputs. 

The timed “anti-passback” feature prevents using the same credentials  
twice  before a programmed waiting period has  elapsed.

Two long lasting solid state LED indicators show the status of the system.  
The left bi-color indicator lights red to indicate power, then green when a 
relay is active (access grant, etc.).  The right indicator flashes yellow to 
indicate that the keypad is in programming mode.

An internal sounder can be programmed to beep each time a key is 
pressed or when an output is activated.  An internal jumper sets the 
sounder volume high or low.

The 

SENSE 

input can be configured  two ways through programming .  

When configured for “Door Sense”, the input is wired to a normally closed 
door position switch to detect when the door is opened or closed.  Forced 
entry or door ajar situations can then be detected. The “Auto-relock” feature 
can also be used  to  turn off the Main Relay output immediately when the 
door is closed after access has been granted to prevent “tailgating”.
When the 

SENSE 

input is configured for “Inhibit”, the input can be wired to 

a normally open “service” switch or automatic timer that will disable access 
while the switch is closed.

The 

REQUEST-TO-EXIT 

input can be wired to a normally open pushbutton 

to provide codeless activation of the Main Relay, Auxiliary Relay, Output #3 
or Output #4 (programmable).

The 

ALARM SHUNT 

signal is available when access is granted.  This 

signal can be programmed to activate any of the relays or solid state 
outputs  to shunt alarm contacts on the access door/gate  preventing the  
triggering of an alarm when an authorized access occurs.

The 920P 

EntryCheck

™ is powered from a 12 or 24V AC or DC source. 

The non-volatile EEPROM memory retains  entry codes and programming 
when power is removed.  An internal jumper is provided to reset the master 
code.  The Main Relay has a 5 Amp capacity.  The Auxiliary Relay has a 2 
Amp capacity.  Two solid state outputs, capable of sinking 100 mA to 
common are programmable for alarm shunting, or to signal forced entry, 
door ajar, keypad lockout, request-to-exit, and keypad active conditions.

P:\INSTALLATION INST\Access Controls\INST-920\INST-920P.vsd     Rev G     01-18     Page 1

INSTALLATION INSTRUCTIONS

920P 

EntryCheck 

TM

801 Avenida Acaso, Camarillo, Ca. 93012  •   (805) 494-0622  •
www.sdcsecurity.com  •  E-mail: [email protected]

SPECIFICATIONS

Mechanical

Dimensions: 3.00" W x 5.75" H x 1.375" D

(1.4375” wall projection)

Electrical

Input Voltage: 12/24 Volts AC or DC
Operating Current: 30 mA typical, 150 mA max

Output Ratings

Main Relay: Form “C” 5 Amps @ 28 Volts max

Auxiliary Relay: Form “C” 2 Amp @ 28 Volts max
Type:  Solid state outputs (Outputs #3 & #4)
Short-to-common 100 mA @ 24 VDC maximum

Environmental

Temperature: -4°F to 140°F (-20°C to 60°C)
Humidity: 5% to 95% non-condensing

Features

4 to 6 digit user codes
4 independent outputs
4 independent timers
2 Form C relay contacts
2 solid state open collector outputs
Program entry codes to activate one or 
two relays
Disable input
Door sense input
Request-to-exit/Reception input
Keypad tamper lockout
Timed anti-passback
Anti-tailgate
Two LED status indicators
Tactile key feel
Audible code entry verification
12V or 24V, AC or DC operation

Keypad programmable
500 user codes
3 User Modes 

PIN or Card
Card Only
Card and PIN

Содержание 920P EntryCheck

Страница 1: ...ide codeless activation of the Main Relay Auxiliary Relay Output 3 or Output 4 programmable The ALARM SHUNT signal is available when access is granted This signal can be programmed to activate any of...

Страница 2: ...ramming mode default master code Step 2 Enter 01 003 2580 2580 1 Assign User 003 with a PIN code of 2580 Activate the main relay when entered Step 3 Repeat Step 2 to enter another unique user PIN or c...

Страница 3: ...er earth ground Connect the green earth ground wire to a good earth grounding point Suggested wiring size is 18 AWG for earth ground Sense Input RE Note The SENSE input gray wire can be programmed as...

Страница 4: ...open Relay 2 toggled The yellow indicator will flash quickly while the 920P stores the new user information in memory The green indicator will light when the new code and card are accepted If the use...

Страница 5: ...larm Shunt Output Default No Output Sets which output activates during the time access is granted Use this output ot shunt alarm contacts attached to the access door This output may be timed or toggle...

Страница 6: ...ps during Main Relay activation Press 41 Sound Sound 1 for Yes 0 for No Solid state Output 4 On time Default 02 Seconds Sets the length of time Output 4 activates when triggered Press 24 Seconds Secon...

Страница 7: ...Access Controls INST 920 INST 920P vsd Rev G 01 18 Page 7 5 750 1 375 3 000 MOUNTING TO SINGLE GANG RECESSED OUTLET BOX 2X Mount at slots 4X Mount at holes With supplied screws and hole expansion anc...

Страница 8: ...P INSTALLATION INST Access Controls INST 920 INST 920P vsd Rev G 01 18 Page 8 OPTIONAL SHROUD SURFACE MOUNT WITH OPTIONAL SHROUD 4X Mount at holes POST MOUNT WITH SHROUD 4 4...

Отзывы: