background image

P:\INSTALLATION INST\Access Controls\INST-920\INST-920.vsd     Rev C     10-14     Page 2

CAUTION

IF THE UNIT IS AC POWERED, MAKE SURE

THAT THE SECONDARY OF THE SYSTEM IS 

ISOLATED FROM EARTH GROUND

!

!

Fig. 2 Wiring Pigtail Color Code

KEYPAD
POWER

WIRE
HARNESS
(E1-E8)

MAIN
RELAY

AUXILIARY
RELAY

ANTI-TAMPER
SWITCH

BACK

JP1

E1

E8

JP2

TO POWER SUPPLY

KEY PAD POWER

12-24 VOLTS

AC OR DC

}

+

-

RED

BLACK

NC

AUXILIARY RELAY

2 AMPS @ 28VDC MAX

}

NO

COM

ORG/BLK

BLK/WHT

BRN/YEL

MAIN RELAY

5 AMPS @ 28VDC MAX

}

NO

COM

NC

ORANGE

WHITE

YELLOW

BLACK

PINK/SALMON

GREEN

GRAY

BLACK

VIOLET

BLACK

BLUE

DOOR POSITION 

SWITCH

[N/C]

REQUEST-TO-EXIT 

SWITCH

[N/O]

GROUND

OUTPUT #4

OUTPUT #3

GROUND

GROUND

SENSE

REQUEST TO EXIT

GROUND

EARTH 

GROUND

CONNECTION

E

1

E

8

E

7

E

6

E

5

E

4

E

3

E

2

C

NO

C

NC

NO

AUXILIARY OUTPUTS

100mA MAX TO COMMON

{

*

*

QuickStart  Programming

You must first enter programming mode to perform any function. The yellow indicator will blink slowly showing that the  920 
EntryCheck™ is in programming mode. Use the option codes to program each function.   After the new data entry is complete for 
each function , the yellow indicator will flash quickly while the data is being stored and the green indicator will light briefly if the 
programming has been accepted.  The red indicator will light if any programming data is entered incorrectly or the function is 
rejected. If a red indicator is seen, the entire function (option code + data)  will have to be fully re-entered.  The keypad will remain 
in programming mode until        # is pressed or after 30 seconds of inactivity.

**

RED/GREEN
POWER/ACCESS
INDICATOR

YELLOW
“PROGRAM”
INDICATOR

KEYPAD

FRONT

Test  your new user code

Enter user code ‘9876#’. The green indicator should illuminate, the 

main relay should activate and the  door should unlock for 5 seconds.

Program the first user code

Step 1. Enter:  

#9#  123456#

Enter the program mode (default master code)

Step 2. Enter: 

03#  4# 

Set the entry code length to 4 digits

Step 3. Enter:  

21# 5#

Set the main relay activate time to 5 sec.

Step 4. Enter:  

01# 001# 9876# 9876# 1#

PIN code ‘9876’ is assigned to User #001 to 
momentarily activate  the main relay  

Step 5. Enter:  

#  

Exit programming mode

**

Adding additional user codes

Once the code length and relay time have been set  you do not need to set them each time 
you additional  users.

To add additional users:

Step 1. Enter:  

#9#  123456#

Enter the program mode (default master code)

Step 2. Enter:  

01# 002# 2222# 2222# 1# 

PIN code ‘2222’ is assigned to User #002 to 
momentarily activate the main relay  

Step 3. Enter:  

01# 003# 2580# 2580# 10# 

PIN code ‘2580’ is assigned to User #003 to 
toggle (on/off) the main relay  

Step 4. Enter:  

#  

Exit programming mode

**

Deleting a  user code

To delete a user:

Step 1. Enter:  

#9#  123456#

Enter the program mode (default master code)

Step 2. Enter:  

02#  002# 002# 

User #002 has been deleted. 

Step . Enter:  

#  

Exit programming mode

**

Содержание 920 EntryCheck

Страница 1: ...o provide codeless activation of the Main Relay Auxiliary Relay Output 3 or Output 4 user programmable The ALARM SHUNT signal is available when access is granted This signal can be programmed to activ...

Страница 2: ...correctly or the function is rejected If a red indicator is seen the entire function option code data will have to be fully re entered The keypad will remain in programming mode until is pressed or af...

Страница 3: ...two wires from the switch to the keypad Connect the door switch to the keypad s SENSE wire gray E8 and COM wire any black wire Inhibit Disable access If an inhibit switch or timer is going to be used...

Страница 4: ...ay 2 toggled The yellow indicator will flash quickly while the 920 stores the new user information in memory The green indicator will light when the new code is accepted If the user number already exi...

Страница 5: ...activates when the keypad is locked out after too many incorrect entry code attempts The lockout time is 60 seconds Press 13 Output Output Output to Activate 0 4 1 Main Relay 2 Auxiliary Relay 3 Outpu...

Страница 6: ...uring Main Relay Default No Selects whether or not the keypad beeps during Main Relay activation Press 41 Sound Sound 1 for Yes 0 for No Solid state Output 4 On time Default 02 Seconds Sets the length...

Страница 7: ...T Access Controls INST 920 INST 920 vsd Rev C 10 14 Page 7 5 750 1 375 3 000 MOUNTING TO SINGLE GANG RECESSED OUTLET BOX 2X Mount at slots 4X Mount at holes With supplied screws and hole expansion anc...

Страница 8: ...P INSTALLATION INST Access Controls INST 920 INST 920 vsd Rev C 10 14 Page 8 OPTIONAL SHROUD SURFACE MOUNT WITH OPTIONAL SHROUD 4X Mount at holes POST MOUNT WITH SHROUD 4 4...

Отзывы: