SDC 101-DE Скачать руководство пользователя страница 10

P:\INSTALLATION INST\Delayed Egress\INST-101DE_KDE.vsd      Rev E               07-15     Page 9

*

Erase All Users (Option 8)

To 

ERASE ALL USERS!!

Press  8#   .

All 

users are erased and the Default Master Code is reset to 

1234

.

*

Returning the Keypad to Factory Default Settings

Short the 

Keypad Reset [J4] 

jumper terminal located on the main controller board.

Press 99# 1234   8#   .

Press 3#1#2#   . Sets the Output #1 (Reset) for 2 seconds.
Press 3#2#2#   . Sets the Output #2 (Auth Exit) for 2 seconds.
Press 3#3#0#   . Sets the Output #3 (Bypass) for latching.

Press 1#02#11#2#   . Adds user # 2  with a code of 11. [Reset]
Press 1#03#22#3#   . Adds user # 3  with a code of 22. [Auth Exit]
Press 1#04#33#4#   . Adds user # 4  with a code of 33. [Bypass]

Press       to exit programming mode.

Remove the shorting jumper from the  

KP RST

terminal.  

*

*

*
*

*

*

*

**

*

Entering Programming Mode

Press  99#  Master Code    .

For example:

99# 1234  

Enters programming mode using the Default Master Code.

*

**

Exit Programming Mode

Press       .

*

*

**

*

*

Changing the Master Code

User 1 is always used as the Master Code and is required  to access  keypad programming. The Factory 
Default Master Code is “1234 ”.    It is strongly recommended that a new Master Code is assigned after 
installation.  WRITE DOWN THE NEW CODE. If the master code is lost, you must use the keypad reset jumper 
on the main circuit board to enter programming mode by using the Default Master Code.

To Change the Master Code (User 1)
1) Enter Programming Mode: Press  99#  Master Code    .
2) Assign new Master Code : Press  1#  01#   New Pin Code# Output Relay #    .

For example:

99# 1234   1# 01# 3871# 0# 

changes the Master code from 1234  to 3871.

3) Press       to exit programming mode.

Output Relay Codes

2

= Reset

3

= Authorized Exit

4

= Bypass

*

Adding a User / Changing User Pin Codes (Option 1)

To add a user:

Press  1#  User Number (2 digits)#   New Pin Code#  Output Relay #    .

For example:

1# 05# 55# 3# 

adds user 5's  pin code as one that will activate authorized exit.

*

REX

TRIG

RESET

IBO

J4

J6

J1

KEYPAD

RESET

C

NO

C NO

C

NO

C

NO

*

Deleting a User (Option 2)

To delete a user:

Press  2#  User Number (2 digits)#    .

For example:

2# 05#  

deletes user 5.

*

Содержание 101-DE

Страница 1: ...OFF BYPASS BYPASS RESET 101 4AM GRN SECURE YEL ALARM RED UNLOCKED OFF BYPASS AUDIBLE SHUNT 101 PAM GRN SECURE YEL ALARM RED UNLOCKED OFF BYPASS AUDIBLE SHUNT ACCESS ON OFF GRN SECURE YEL ALARM RED UNL...

Страница 2: ...ST Delayed Egress INST 101DE_KDE vsd Rev E 07 15 Page 1 Any suggestions or comments to this instruction or product are welcome Please contact us through our website or email engineer sdcsecurity com A...

Страница 3: ...o re secure the door Unlocking the door for extended periods of time Authorized Bypass mode is accomplished by entering an Authorized Bypass code on the integral keypad momentarily turning the optiona...

Страница 4: ...ture assembly with tray required for proper operation of the trigger switch EMLock Door Mount magnet and armature tray assembly per template ARMATURE HOLDER ARMATURE 1 2 DOOR 1 1 4 SEX NUT 5 16 18 ARM...

Страница 5: ...d PUSHUNTILALARMSOUNDS DOORCANBEOPENEDIN15 SECONDS RECESSED MOUNTING DRY WALL 3 3 4 PUSHUNTILALARMSOUNDS DOORCANBEOPENEDIN15 SECONDS KEY CYLINDER INSTALLATION KDE Model Only 1 Cut hole in dry wall to...

Страница 6: ...E WALL or POST MOUNTING with WEATHER SHROUD 1 Use optional 3 Gang Box inside optional Shroud as a template to drill pilot holes through shroud and into post or wall 2 Mount 3 Gang Box and Shroud to Po...

Страница 7: ...PACKING FOAM BETWEEN WALL AND UNIT TO PREVENT DAMAGE TO FACEPLATE USE 1 1 4 SCREWS SUPPLIED WITH WALL MOUNT FRAME TO HANG UNIT TEMPORARILY FOR WIRING PURPOSES VIEW A A WIRE UNIT AS SHOWN SHOWN WITH NO...

Страница 8: ...7 8 3 4 5 6 7 8 l PAIR OF DOORS 101 DE 101 KDE PWR LOCK RED R NO C TRIG REX RESET C NO C NO C NO To Power Supply WARNING CONTACT THE AUTHORITY HAVING JURISDICTION FOR APPROVAL PRIOR TO SELECTING DELAY...

Страница 9: ...lay is counting down with audible alarm voice instructions Once the display reaches 00 the door will unlock 15 14 01 DELAYED EGRESS MODE 00 00 The door is unlocked and has been opened ALARMED UNLOCKED...

Страница 10: ...ess Changing the Master Code User 1 is always used as the Master Code and is required to access keypad programming The Factory Default Master Code is 1234 It is strongly recommended that a new Master...

Страница 11: ...ctions 1581DEV SPST only D Door position sensor indicates door open and door closed Commonly used to verify egress after alarm and exit delay activation Not available with 1581DE 1576DE or 1575DE VI S...

Страница 12: ...ystem 6 Upon power up you must manually reset the lock to activate the IBO input P INSTALLATION INST Delayed Egress INST 101DE_KDE vsd Rev E 07 15 Page 11 Connection to a Infant Patient Monitoring Sys...

Страница 13: ...R Power Supply Power Transfer Hinge or Loop MSB550 PSB560 REX Bar Lock Power RED LED GRN LED LED COM 101 1A or 101 1AK REMOTE ANNUCIATION REMOTE TRIGGER MSB550 PSB560 REX TRIG RESET IBO J4 J6 J1 KEYPA...

Страница 14: ...SECURE YEL ALARM RED UNLOCKED OFF BYPASS BYPASS RESET 101 4AM GRN SECURE YEL ALARM RED UNLOCKED OFF BYPASS AUDIBLE SHUNT 101 PAM GRN SECURE YEL ALARM RED UNLOCKED OFF BYPASS AUDIBLE SHUNT ACCESS ON OF...

Отзывы: