Diesel Engine. Sets the engine type for Diesel and monitors the glow plug input to make sure the glow
plugs are warm before cranking the starter.  If the glow plug wire is not connected, the built-in timer
waits 15 seconds before automatically cranking the starter.

22.

Ignition 2 Relay Program. 

Selects one of three operating modes for the Ignition 2 relay output:

Ignition 2, Accessory 2, or Starter 2. 

23.

Horn Output. 

When set for Horn Output the horn wire will pulse when the alarm is triggered.  When

Ignition 3 Output is selected, the output will activate during remote start to trigger a relay for Ignition 3. 

24.

Turbo Timer. 

When enabled, if the emergency brake has been applied Ignition power will be kept On

for a predetermined time (2min. Factory Default) from the application of the emergency brake.

25.

Extended Parking Lights.

When Enabled, upon Disarming Parking lights will turn On for 30 seconds

or untill the Dome light turns Off.

26.

Warn-Away Pager Report.

When Enabled, Warn-Away report will be sent to the pager. If Disabled

no Warn-Away report will be sent to the pager.

27.

Factory Rearm Function.

Camera Flash Mode- pulses Factory Rearm output for 1 second every time

the camera is activated. Factory Rearm Mode - enables the output to operate as a Factory Rearm

output.

28.

Zoom Mode.

Picture Zoom Mode- select zoom 1X, 2X, 4X

29.

Picture Orientation.

Select Normal or Inverted

Содержание VISIONGUARD 8000

Страница 1: ...VISIONGUARD 8000 VEHICLE SECURITY SYSTEM WITH BUILT IN CAMERA AND REMOTE START PRODUCT MANUAL...

Страница 2: ...ill be a maximum service charge of 25 00 per calendar year if required for repair and or replacement of any defective parts A copy of the original purchase receipt must accompany any products returned...

Страница 3: ...wn Page 13 Quick Stop Page 13 Automatic Start Mode Page 13 Turbo Timer Feature Page 14 Manual Transmission Remote Starting Page 14 5 Extended Features Page 14 Ignition Door Locking Page 15 Ignition Do...

Страница 4: ......

Страница 5: ...Contents Main Unit with built in ScyNet Network Interface Port Two Way Full Color Picture Ready LCD Remote Transmitter Camera Remote Transmitter Receiver One Way 5 Button Random Code Remote Transmitte...

Страница 6: ...1 output This output will remain on for as long as the button is pressed Button 4 Activates the Remote Start feature Button 5 is the Page Shift button Each time the Shift Button is pressed the LED on...

Страница 7: ...ransmitter If all four transmitters are to be used with both cars program transmitters A and B into the first vehicle in the manner described above Program transmitters C and D by pressing the Shift b...

Страница 8: ...en pressed together for 2 seconds Activates the Auxiliary 1 output normally used for trunk release Button 4 is the Confirmation button Pressing button 4 for 2 seconds activates the system s confirmati...

Страница 9: ...replacement in time Depending on the amount of use the battery may last up to two months before it needs replacement When the battery needs replacing the system s operating range will decrease the LC...

Страница 10: ...utton 4 The transmitter will beep once The transmitter will display CHIRP ON for on or CHIRP OFF for off NOTE SHOCK TURBO SENSOR 1 AND SENSOR 2 ARE NOT USED VALET To set the VALET mode ON or OFF 1 Pre...

Страница 11: ...VisionGaurd 8000 Page 7 Camera Features...

Страница 12: ...VisionGuard 8000 Page 8...

Страница 13: ...s an impact to the vehicle An optional sensor is disturbed When the alarm triggers the siren will sound the horn will honk and the parking lights will flash If the system is triggered by the doors hoo...

Страница 14: ...ne time silent operation Note The open zone warning chirps will not be bypassed when the system is Armed or Disarmed silently Passive Arming When programmed for the optional Passive Arming feature the...

Страница 15: ...dure be sure to have the ignition key ready and know the location of the override switch To Emergency Override the system 1 Unlock the door using the key 2 Enter the vehicle The system will trigger an...

Страница 16: ...icle in the event the system is accidentally disarmed With the Automatic Rearming feature enabled the alarm will automatically rearm an lock 30 seconds after disarming The Automatic Rearming feature f...

Страница 17: ...Quick Stop The Quick Stop Feature allows you to exit the vehicle while keeping the engine running for quick stops To leave the vehicle running 2 While the engine is running push the Remote Start butt...

Страница 18: ...remote start button on your transmitter parking lights will flash twice and stay on indicating Manual Start Mode is enabled turn off the Ignition switch the engine will remain running Open and close t...

Страница 19: ...activation power sunroof control auxiliary lighting audio video system control and more The Pulsed operation setting allows an output to activate as long as the button is held one way transmitter onl...

Страница 20: ...g 6 Verify with the owner the mounting locations for all visible components including the LED and Override switch 7 Verify with the owner the optional features of the VisionGuard 8000 and the features...

Страница 21: ...e Siren Choose a siren mounting location that is away from heat sources such as exhaust manifolds and where it cannot be easily accessed from underneath the vehicle Be sure to face the siren downward...

Страница 22: ...chless mode does not provide satisfactory operation Pin 3 WHITE RED WIRE Auxiliary 2 Output 500 mA Connect to a relay or module for an optional feature such as power window activation etc the output m...

Страница 23: ...wire to the circuit that shows 12V or ground only when the parking lights are on and set the internal parking light relay jumper to the proper polarity For parking light circuits exceeding 10 amps a...

Страница 24: ...olarity jumper will be visible next to the parking light relay Set the jumper for the correct polarity output as described below then reassemble the main unit case Parking Light Output Selects the pol...

Страница 25: ...ystem Programming 2 Press Transmitter Button 3 The siren will chirp 6 times indicating that the reset signal was received All System Programming parameters are now set to factory default settings The...

Страница 26: ...to Rearming Mode Disabled Enabled 3 Arming Chirps Siren Chirps On Silent Siren Horn Chirps On 4 Ignition Door Locking On Off Set Override Code 5 Ignition Door Unlocking Unlock All Unlock Driver Only O...

Страница 27: ...for Auxiliary 2 14 Disarm with Auxiliary 1 When selected activating the Auxiliary 1 output usually used to open the trunk will disarm the alarm 15 Start in Valet Mode Selects whether or not the vehicl...

Страница 28: ...to trigger a relay for Ignition 3 24 Turbo Timer When enabled if the emergency brake has been applied Ignition power will be kept On for a predetermined time 2min Factory Default from the application...

Страница 29: ...POSITIVE HORN WIRE 12V Brown White HORN OUTPUT TO NEGATIVE HORN WIRE 12V Brown White HORN OUTPUT Positive Horn Honk Negative Horn Honk Blue Yellow Wire GLOW PLUG INPUT Yellow Wire IGNITION GLOW PLUG...

Страница 30: ...igger using inverter or relays Reverse Polarity Vacuum Adding Actuators Follow the diagrams below for connecting basic door lock systems For Two Stage door lock systems separately unlocks driver and p...

Страница 31: ...sionGuard 8000 is equipped with a dedicated Passenger Unlock output allowing Two Stage Door Lock operation When connected as shown below disarming the system will unlock only the driver s door Pressin...

Страница 32: ...Page 28 VisionGaurd 8000 Two Stage Door Lock Diagrams cont d Two Stage Reverse Polarity Two Stage Adding Actuators...

Страница 33: ...es with Part 15 of FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interfe...

Страница 34: ...8000 Starter Diagnostics Starter doesn t start and parking lights flash 3 Times Engine RPM not detected Hood Trigger is active 4 Times Brake Trigger is active 5 Times Unit is in Valet service mode an...

Страница 35: ...VisionGaurd 8000 Page 31...

Страница 36: ...Unlock Output 500mA Blue Orange Remote Start Output 500mA Black Ground Red 12V Battery Input 3 Violet Door Trigger Input Green Door Trigger Input White Black Hood Trunk Input Orange Armed Output 500mA...