Page 14 - Galaxy 2000RS Plus
Entering System Programming
Enter System Programming:
1. Turn on ignition.
2. Within 5 seconds, press the valet switch 5 times.
· The parking lights will provide three blinks, indicating that you have entered Programming.
3. Press the valet switch the number times equal to the System Parameter you want to change.
· The parking lights will flash each time the valet switch is pressed.
4. Within 5 seconds, press the Brake Pedal Number of times corresponding to the desired operating
mode for that System Parameter, within two second parking light will flash to indicate the setting.
1 flash
2 flashes
3 flashes
5. When you are finished, turn off the ignition to save the changes.
Default Reset
Following this procedure will set all System Programming Parameters to factory default settings.
1. Enter System Programming.
2. Press the Brake Pedal three times.
· The parking lights will flash 6 times indicating that the reset signal was received.
· All System Programming parameters are now set to factory default settings.
· The Valet Mode is off.
3. Turn off ignition.
Programmable System Options
The following is a description of the programming options of the system. Some of the program branches
control more than one option, and may require accessing a particular branch number twice in order to
program all desired features.
1.
Ignition Door Locking.
Selects whether or not the system will automatically lock the doors 5 seconds
after the ignition key is turned on.
2.
Ignition Door Unlocking.
Selects whether or not the system automatically unlocks the doors when
the ignition is turned off. The Ignition Door Locking feature may be programmed to unlock all doors or
the driver’s door only. If driver’s door only is selected, the optional Passenger Unlock wire must be
connected. (
See Two Stage Door Lock Diagrams)
3.
Door Unlock Pulse.
Selects between one pulse or two pulse operation for the door unlock output.
Many new import vehicles’ factory door locking systems require two pulses on the proper wire to unlock
the doors. These systems can be interfaced directly without the use of relays or any additional circuitry
by programming the system for double unlock pulse.
4.
Door Lock Pulse Length.
Selects between a 1-second and a 3-second output for door locking and
unlocking. Program to 3 seconds for vehicles equipped with vacuum door locking systems.
5.
Aux 2 Auto Activate with Arm.
When selected, the Auxiliary 2 output will activate when the system
S
Sy
ys
stte
em
m P
Prro
og
grra
am
mm
miin
ng
g
Содержание Galaxy 2000RS-MDL
Страница 1: ...2 20 00 00 0R RS S M MD DL L S SE ER RI IE ES S REMOTE START SYSTEM PRODUCT MANUAL...
Страница 4: ......
Страница 25: ...Galaxy 2000RS Plus Page 21...
Страница 26: ...Page 22 Galaxy 2000RS Plus...