SRMETER2 Surface Resistance Meter

Installation, Operation and Maintenance

Description

The SCS 

SRMETER2

 Surface Resistance Meter is a 

portable battery powered checker fitted with built-in 

parallel electrodes that allow for tests of material surface 

resistance.  This meter is designed for quick checks 

of surface resistance for ESD control applications in 

electronics manufacturing or handling environment.  The 

Surface Resistance Meter is equipped with an automatic 

test voltage selector.  The test voltage will switch from 

10V to 100V should the measured resistance exceed 1 

x 10

5

 ohms.  Two banana jacks and an electrode toggle 

switch allow for the connection of two external 5 pound 

electrodes that measure surface resistance point to 

point (Rtt) or resistance to equipment ground (Rtg).

December 2018

ESD protected area products should be tested:
A. Prior to installation to qualify for listing in user’s ESD 

  control plan.  Approved ESD materials (see product 

  qualification table at ANSI/ESD S20.20 Table 3 EPA 

  ESD control items).
B. During initial installation.
C. For periodic checks of installed products as part of 

  ANSI/ESD S20.20 Compliance Verification testing per 

  ESD TR53.
Compliance Verification Plan

“A Compliance Verification Plan shall be established 

to ensure the Organization’s fulfillment of the technical 

requirements of the ESD Control Program Plan. Process 

monitoring (measurements) shall be conducted in 

accordance with a Compliance Verification Plan that 

identifies the technical requirements to be verified, the 

measurement limits and the frequency at which those 

verifications shall occur. The Compliance Verification 

Plan shall document the test methods and equipment 

used for process monitoring and measurements. If the 

test methods used by the Organization differ from any 

of the standards referenced in this document, then 

there must be a tailoring statement that is documented 

as part of the ESD Control Program Plan. Compliance 

verification records shall be established and maintained 

to provide evidence of conformity to the technical 

requirements.
The test equipment selected shall be capable of 

making the measurements defined in the Compliance 

Verification Plan.” (ANSI/ESDS20.20 section 7.3)  The 

Surface Resistance Meter is not recommended for use 

in Resistance to Ground (Rtg) measurements.

Packaging

1  Surface Resistance Meter

1  9V Battery

1  Certificate of Calibration