TB-9026 

Page 2 of 6

© 2015 DESCO INDUSTRIES, INC.

Employee Owned

SCS 

- 926 JR Industrial Drive, Sanford, NC 27332 • (919) 718-0000 • Website: 

StaticControl.com

Installation

Wire Attachment

The AC adapter should not be connected during the 

wire attachment process. Attach 18 AWG wires to the 

unit as described below. Strip vinyl insulation at each 

end of the wires to approximately 1/3 in. (8 mm). Twist 

the stranded wire on each end before inserting wire into 

each connector location.

Attach ground wire to the GND connector on the back of 

the unit. Insert a small blade screw driver into the orange 

slot above. Push inward and insert the stripped wire fully 

into the hole in the green connector. Hold wire fully in 

and release the screw driver to allow the wire to catch.

If you are planning to use the Ground Man Plus Ground 

Monitor output to the tool, attach wire to the Out 

connector on back of unit. Insert the wire as described 

above.

Attach the impedance monitor wire(s) to the chosen 

ground line(s) G1, G2, G3 connector(s) on back of unit. 

Insert the wire as described above.

AC/DC Adapter Connection

Connect the circular plug of the AC/DC Adapter into the 

power jack on the back of the unit.

Mounting

Determine the mounting location of the Ground Man 

Plus Ground Monitor.  Attach the unit using one of the 

following recommended methods:

•  Screws

•  SCS Dual Lock Fastener

Enabling or Disabling Monitoring of 

Ground Lines

Sometimes not all three ground points in the tool need 

to be monitored. This procedure will set up the number 

of ground lines (G1, G2, G3) that will be used, so that 

there is no need to put jumpers or shunts on the unused 

ground monitoring inputs. The AC Adapter should not be 

plugged in at this moment.

alarm so that it is not missed. The unit will respond to 

either positive or negative voltage. The alarm is also 

activated when the wrist band is worn too loosely and 

the loop resistance level is exceeded. The red LED 

indicates an over the resistance limit without a voltage 

being generated on the person at the same time. The 

green LED indicates proper connection of operator. 

A green LED plus blinking red LED will indicate if there 

is a body voltage generated; operator may still be 

connected properly. The green LED is off when a dual 

conductor ground cord is not plugged into the jack.

Enabling and Disabling Audible Alarm

The audible alarm can be enabled or disabled by 

momentarily pressing a recessed miniature push-button 

Set switch located on the back of the unit while the 

monitor is powered on. Use a pin to press the switch.

Environmental Conditions

This equipment has been tested and found to be safe to 

operate within these environmental conditions:

•  This is not a warranty of equipment performance within 

these conditions.

•  Indoor use only

•  Ingress Protection: IPX0

•  Altitude: Up to 2,000 m

•  Mains supply voltage fluctuations up to ± 10% of the 

nominal voltage.

•  Transient over voltages up to the levels of over voltage 

category II.

•  Temporary over voltages occurring on mains supply.

•  Pollution degree 2.

•  Temperature: Maximum 110°F / 43°C Minimum 50°F / 

10°C

•  Humidity: Maximum relative humidity 80% for 

temperatures up to 31°C decreasing linearly to 50% 

relative humidity at 40°C .

Specification

Figure 2. Rear view of Ground Man Plus Ground 

Monitor.

Power

AC/DC Adapter

Universal 100 - 240VAC, 0.5A, 

~50 - 60Hz

Output: 12VDC, 1.5A

General

Dimensions (approx) 2.4" W x 0.85" H x 2.6" D (61 

mm W x 21 mm H x 66 mm D)

Weight (approx)

75g