4.  A “PASS” test result is indicated by illumination 

of the green LEDs. A “FAIL LOW” test result is 

indicated by illumination of the red LEDs. A “FAIL 

HIGH” test result is indicated by illumination of the 

yellow LEDs. 

 

If your ESD test fails, check your wrist strap 

and footwear to ensure that they are being worn 

correctly and/or need to be replaced.

NOTE: Failures may be caused by dry skin or minimal 

sweat layer. For wrist straps, try using an approved 

dissipative hand lotion such as 

Menda Reztore™ ESD 

Hand Lotion

 to your wrist prior to use. Footwear test 

results can be improved by taking a short walk to build a 

sweat layer for better conductivity.
The Dual Combination Tester may also be used to 

test smocks or garments that feature a grounding 

mechanism for operators using a coiled cord 

connection.

Figure 10. Bridging the test switch’s contacts to initiate 

the test

Figure 11. Using the Dual Combination Tester

Содержание 770758

Страница 1: ...Combination Tester 770751 Limit Comparator 770752 Power Adapter 100 240 VAC Input 12 VDC 0 5 A Output All Plugs Per ANSI ESD S20 20 section 7 3 A Compliance Verification Plan shall be established to e...

Страница 2: ...rd here to test your wrist strap F Dual Wire Wrist Strap Jack Insert your dual wire wrist cord here to test your wrist strap G Wrist Strap Status LEDs Displays the wrist strap test results H Relay Ter...

Страница 3: ...ON 10 Megohms 1 x 107 ON OFF 35 Megohms 3 5 x 107 default setting DIP switch 5 must be ON default setting for the wrist strap test to be active The wrist strap test will be disabled if DIP switch 5 i...

Страница 4: ...Secure the backplate using the two Phillips head screws and nuts 4 Plug the ground cord into the ground jack located on the bottom of the tester and connect the ring terminal to equipment ground This...

Страница 5: ...onding jack located on the face of the Dual Combination Tester Place one foot on each foot plate 3 To begin the test use your finger to bridge the test switch s inner and outer contacts The blue stand...

Страница 6: ...to ensure that they are being worn correctly and or need to be replaced NOTE Failures may be caused by dry skin or minimal sweat layer For wrist straps try using an approved dissipative hand lotion s...

Страница 7: ...bs 2 5 kg Maintenance To maintain optimum performance cleaning should be performed on a regular basis Use a minimum of 80 Isopropyl alcohol to clean the foot plate and test switch Other cleaners are s...