Maintenance
Cleaning
Disconnect the power adapter from the device. Clean
the EM Aware Monitor and its antenna using a dry brush
or vacuum cleaner. Clean its contacts using a contact
cleaner or brush, and tighten all connections. Do not
reconnect the power adapter until cleaning is finished.
Repairs and Servicing
There are no user-serviceable parts. Do not attempt to
repair the EM Aware Monitor yourself. Contact an SCS
sales representative or authorized distributor to request
inspection and repair.
Calibration
Contact an SCS sales representative or authorized
distributor to request product calibration if necessary.
Specifications
Power
Power Adapter
100-240 VAC
50-60 Hz
ESD Event Monitor
Output: 7 .5
voe
@ 1.5 A
Output Plug Polarization: Center
Positive
Output Plug: 5.5 mm O.D. x 2.1
mm I.D. x 9.5 mm L
Measurement
Magnitude ESD Event
ESD Event
Default setting: 80 dBµV
Threshold
Raw Input Signal
60 dBµV (~1mV) to 134 dBµV
(~5.0 V)
Filtering Function
ESD
Static Voltage Monitor
Measurement
Static Voltage
Setting Range
Output
Static Voltage - Change of
electrostatic field
12.5 V, 100 V, 250 V, 500 V, 1000
V, smart coefficient adjust
Ethernet
Ionizer Voltage and Decay Monitor
Compatible Ionizer Steady-State DC
Max. Decay Time
16 seconds** max, typical
Reading
Max. Decay Test
±5 V
Voltage
Connectivity
Input
SMA Connector for Remote
antenna
Outputs
RJ45 connector for Ethernet
output; 2-position terminal block
for relay output
General
Alarm
Display
Dimensions
(antenna not
included)
Weight
Buzzer
LCD
3.17" W x 2.25" H x 1.26" D
(81 mm W x 57 mm H x 32 mm D)
183 g
**The readings of ionization voltage and decay under
identical conditions may not always correlate with a
charged plate monitor. The EM Aware Monitor is not
intended to replace regular testing of ionizers by a
charged plate monitor.
Limited Warranty, Warranty Exclusions, Limit of
Liability and RMA Request Instructions
See the SCS Warranty -
StaticControl. com/Limited-Warranty .aspx
TB-9097
Page 19 of 19
© 2019 DESCO INDUSTR ES INC
Employee OWned