TB-9080
Page 16 of 18
© 2017 DESCO INDUSTRIES, INC.
Employee Owned
SCS
- 926 JR Industrial Drive, Sanford, NC 27332
East: (919) 718-0000 | West: (909) 627-9634 • Website:
StaticControl.com
Specifications
Power
Power Adapter
100-240VAC
50-60 Hz
Output: 7.5VDC @ 1.5A
Output Plug Polarization: Center
Positive
Output Plug: 5.5 mm O.D. x 2.1
mm I.D. x 9.5 mm L
ESD Event Monitor
Measurement
Magnitude ESD Event
ESD Event
Threshold
Default setting: 80 dBµV
Raw Input Signal
60 dBµV (~1mV) to 134 dBµV
(~5.0V)
Filtering Function
ESD
Static Voltage Monitor
Measurement
Static Voltage - Change of
electrostatic field
Static Voltage
Setting Range
12.5V, 100V, 250V, 500V, 1000V,
smart coefficient adjust
Output
Ethernet
Ionizer Voltage and Decay Monitor
Compatible Ionizer Steady-State DC
Max. Decay Time
Reading
16 seconds** max, typical
Max. Decay Test
Voltage
(+) and (-) 5 Volt
Connectivity
Input
SMA Connector for Remote
antenna
Outputs
RJ45 connector for Ethernet
output; 2-position terminal block
for relay output
General
Alarm
Buzzer
Display
LCD
Dimensions
(antenna not
included)
3.17" W x 2.25" H x 1.26" D
(81 mm W x 57 mm H x 32 mm D)
Weight
183g
**The readings of ionization voltage and decay under
identical conditions may not always correlate with a
charged plate monitor. The EM Aware Monitor is not
intended to replace regular testing of ionizers by a