background image

SL20M   SL22M plissé   

contr

ol unit 

SL1807

Control unit 

This unit is used to control the polarity inversion necessary for

the correct function of the motor, which would not be realised

when using normal switches.

Each control unit can control one blind, or can simultaneously

control a group of up to four blinds, depending on the requi-

rements of the system. 

The limited dimensions of the unit allow its insertion inside the

standard electrical back box. 

It comprises an electronic card equipped with a protection fuse

that can be easily replaced.

Technical features

Dimensions (mm)

40x40x20

Input

supply, marked as 

24V dc

connection to the double switch or to the radio receiver, 

marked by a contact graphic

connection from another control unit, marked as 

REMOTE

;

this is used only for centralised connections to other groups

(see note below)

Output

• 

connection to the blind motor or to a bus line for connection  

towards other control units; marked as 

MOTOR

Fuse

6,3 A

Working temperature

-20 +60°C

14

Note

The 

REMOTE

terminal is available to allow the installer the opportunity to meet the client’s

requirements for a variety of group control combinations. This is achieved by connecting  the

REMOTE terminal to the MOTOR output terminal of another SL1807 CONTROL UNIT. A typical

application would be where a single control is required for a number in blinds already control-

led individually by a control unit. By connecting a new control unit via the  MOTOR output in

parallel with all the REMOTE  terminals of the existing control units involved in the total opera-

tion, the additional control unit, once has been activated, will control all the control units simul-

taneously, whilst still allowing control of each motor separately. 

Multiple control systems can be built up using this procedure.

MOTOR

REMOTE

24 Vdc

CO

M
NO

CO

M
NO

A

B

A

B

MOTOR

REMOTE

24 Vdc

COM

NO

COM

NO

A

B

A

B

Output for

blind motor

Input for additional
control unit

Input for power supply

Input for connection to switches
and/or radio receiver

SL20 22M plissé_GB  15-05-2007  9:45  Pagina 14

Содержание SL20M

Страница 1: ...635 info pellini net SL20M SL22M pliss MTL015GB Edition 05 07 www pellini net visual design stefanosiboni it Technical Catalogue english double glazed unit 20 mm 22 mm ScreenLine SL22M pliss SL20M pli...

Страница 2: ...in order to avoid excessive stress on the cords and to guarantee a longer life to the compo nents Faster speed for raising and lowering The motor and the entire electronic blind management system are...

Страница 3: ...rollers double bearings in output Total Ratio 214 1 95 1 in the reducer 2 25 1 in the corner key Encoder Magnetic encoder in Neodymium with a very high magnetic field with a resistance strength up to...

Страница 4: ...d aluminium SL20C System Dimensions 20 x 6 5 mm Upper extruded open spacer bar Lower extruded U shaped spacer bar with 2 mm clipping projection Sides L shaped side spacer with 8 mm pro jection on one...

Страница 5: ...ScreenLine 5 SL20 22M pliss _GB 15 05 2007 9 45 Pagina 5...

Страница 6: ...Internal motor with encoder SL1708 Plastic corner key 20x6 5 mm SL1740 Extruded L shaped spacer bar 20x6 5 mm SL1217 ScreenLine plastic label 14 mm Verosol pleated fabric SL1165 1 mm internal cord SL1...

Страница 7: ...ted SL1052 Calibrated tube SL1854 Internal motor with encoder SL1820 Plastic corner key 22 mm SL1772 Extruded C shaped spacer bar 22x6 5 mm SL1217 ScreenLine plastic label 14 mm Verosol pleated fabric...

Страница 8: ...EXTRUDED L SHAPED SPACER BAR EXTRUDED U SPACER BAR 2 6 5 12 OUT IN 14 mm PLEAT 20 12 55 SL22M pliss double glazed unit 8 3 12 6 5 EXTRUDED C SPACER BAR EXTRUDED U SPACER BAR 2 6 5 12 OUT IN 14 mm PLEA...

Страница 9: ...ss dimensions for double glazing 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 30 35 40 45 50 60 70 80 90 100 110 120 130 140 150 Width cm Height cm W H SL22M pl...

Страница 10: ...d to insert the corner key into the bottom of each side spacer bar fill them with the molecular sieve and block the open end with butyl or fibres to avoid any loss of sieve during further operations A...

Страница 11: ...e pressing system Gas filling Using the appropriate equipment and in accordance with the standard procedure replace the internal air with argon Testing After the press operation but prior to applying...

Страница 12: ...on tubes should remain straight and not damaged Where the final seal is applied horizontally any glass deflection should be corrected by equalisation after curing i e the glass surfaces should be para...

Страница 13: ...in order to avoid any friction between bottom rail and glass surface during raising and lowering Transport and storage For transport and storage procedures please check the recom mendations contained...

Страница 14: ...marked as MOTOR Fuse 6 3 A Working temperature 20 60 C 14 Note The REMOTE terminal is available to allow the installer the opportunity to meet the client s requirements for a variety of group control...

Страница 15: ...cks one for the main s power supply connection and the other for the 24V dc output It can supply up to a maximum of 4 motors Technical features Dimensions mm 110 130 included fixing fins x85x50 height...

Страница 16: ...malfunction Cover the area around the connection with more secondary sealant to ensure no possibility of water penetration creating a short circuit after glazing Ensure that there is no possibility of...

Страница 17: ...oid sudden stops which results in less stress on the components When the motor experiences a sudden increase in the energy absorption or a remarkable reduction of the motor speed as a possible result...

Страница 18: ...ScreenLine 19 SL20M SL22M pliss single control 230V ac SL20 22M pliss _GB 15 05 2007 9 45 Pagina 19...

Страница 19: ...SL20M SL22M pliss centralised control with switch and or remote control 20 ScreenLine 230V ac SL20 22M pliss _GB 15 05 2007 9 45 Pagina 20...

Страница 20: ...c A B G ScreenLine 21 SL20M SL22M pliss centralised radio control with without switches for two groups A B G No 1 group control No 2 group control General group control SL20 22M pliss _GB 15 05 2007 9...

Страница 21: ...and single control for two groups 22 ScreenLine 230V ac 230V ac B A G C 1 C 2 C 3 C 4 C 5 C 6 C 7 C 8 A B No 1 group control No 2 group control C x G Single blind control General group control SL20 22...

Страница 22: ...M pliss centralised control with switch and or remote control and single switch 230V ac 230V ac G C 1 C 2 C 3 C 4 C 5 C 6 C 7 C 8 C x G Single blind control General group control SL20 22M pliss _GB 15...

Страница 23: ...6 5mm spacer bars 12mm sight line ONLY Fill in the secondary sealant depth column where you require a different secondary sealant depth the size of the blind provided will be adjusted to meet our own...

Страница 24: ...the Purchaser who within 3 three days after receipt must inform the Company about any defect damage theft shortage and delays occurred during the transport in order for the latter to file a complaint...

Страница 25: ...might cause delays to the Company to settle the complaint It is agreed that should this be the case the Company will not be liable for such delays Complaints regarding Products having been cut used a...

Отзывы: