SCOTTY WOOD FURNACE – INSTRUCTION MANUAL
SCOTTY
3/31/2006
3
SECTION 1 – OPERATING INSTRUCTIONS
KERR SCOTTY Wood Furnace Model DB-102
Certified by the Canadian Standards Association
Manufactured by:
Parrsboro Metal Fabricators Ltd.
P.O. Box 637, Crossroads
12118, Highway 209
Parrsboro, Nova Scotia, Canada
B0M 1S0
Specifications
Length
46 ½”
Width
22 ½”
Height
43”
Shipping Weight
344 lb
Fire Box 1/8”plate Length
27 ½”
Diameter
18”
Secondary Heat Exchanger
14 gauge steel
Fire Box Door
Cast Iron
12” x 12”
Warm Air Plenum
29” x 20 ¾”
Return Air Plenum
14 ½” x 20 ¾”
Air Filter Size
16” x 20” x 1”
Blower Size
G9 – 10
Blower Motor
¼ hp
CFM
1000 (Required)
Smoke Pipe
7” Inside Diameter
Floor to smoke pipe center
36”
Output (max)
70,000 Btu/h
Fuel
Wood 24” logs
Electrical Rating
Volts 120, Cycles 60, Amps 15
NOTE
– Keep this manual in a safe place for future reference. Follow manual
carefully for the correct way to install and operate this unit.
CAUTION
– Do not fire this unit until operating instructions have been read and
fully understood.
INSTALL WOOD FURNACE ONLY ON A FURNACE DUCT SYSTEM AND
CHIMNEY THAT ARE IN GOOD CONDITION AND APPROVED FOR USE.
SAVE THESE INSTRUCTIONS