INSTALLATION OF THE 

SCOTT ACCOUNTABILITY SYSTEM

QUEUE INTERFACE ACCESSORY

The QUEUE Interface Accessory, SCOTT P/N 201211-01, must be properly 

installed and powered to operate correctly.

If you have any questions about installing the QUEUE Interface assembly, consult a qualified 

electrician before proceeding.

1.  Choose a suitable location for the QUEUE Interface Accessory:

a)  Mount the assembly will be readily accessible but will not pose a hazard to 

occupants of the vehicle.

b)  Choose a location where the QUEUE Interface Accessory will not be exposed 

to excess moisture.

c)  The mounting surface should be flat so that tightening the mounting screws 

will not bend or stress the back plate of the QUEUE Interface. 

2.  Place the QUEUE Interface Accessory in the desired position and mark the six 

(6) mounting holes through the two mounting tabs on the housing. 

WARNING

WHEN INSTALLING WITHIN A VEHICLE, 

DO NOT MOUNT THE QUEUE INTERFACE 

ACCESSORY IN A LOCATION WHERE IT 

MAY PRESENT A HAZARD TO OCCUPANTS 

OF THE VEHICLE. FAILURE TO PROPERLY 

LOCATE AND PROPERLY MOUNT THE 

QUEUE INTERFACE ASSEMBLY MAY RESULT 

IN SERIOUS INJURY.

CONNECT THE POWER (TWO VERSIONS)

UNIVERSAL POWER 

CORD (CONNECT 

TO POWER SUPPLY)

HARD WIRE POWER CORD 

(CONNECT TO VEHICLE 

12V or 24V POWER)

3.  When installed in a vehicle, the QUEUE Interface Accessory must be securely 

mounted in either a vertical or horizontal position using the mounting holes pro-

vided. Use #10 flat head machine screws in a minimum of four (4) of the holes 

(two on each end). Recommended torque is 2.5 ft-lbs. or 30 inch-lbs.

4.  Power supply considerations:

a)  For use with the 100–240 VAC power converter, use only QUEUE Interface 

Wall Power Assembly P/N 201332-01. Choose a location for mounting the as-

sembly where the power source necessary can be reached within the length 

of the power supply cord which is approximately six (6) feet. 

b)  When powered by 12 VDC supplied from the vehicle, use only SCOTT Hard 

Wire Power Cord P/N 201222-01. Attach the ring terminals to the appropriate 

power terminals on the vehicle. The Hard Wire Power Cord is approximately 

12 feet long and is equipped with an in-line fuse which uses a blade style low-

voltage 2 amp fuse, SCOTT P/N 31002883.

MOUNTING 

HOLES

MOUNTING 

HOLES

CAUTION

THE QUEUE INTERFACE ACCESSORY 

MUST BE INSTALLED AT LEAST THREE (3) 

FEET AWAY FROM WHERE AN RFID CARD 

READER/WRITER MAY BE USED. CLOSE 

PROXIMITY OF THE QUEUE INTERFACE MAY 

CAUSE THE RFID CARD READER/WRITER 

TO MALFUNCTION. FAILURE TO RECOGNIZE 

A MALFUNCTION OF THE RFID CARD 

READER/WRITER AND TAKE THE PROPER 

CORRECTIVE ACTION MAY RESULT A FAILED 

READ/WRITE OF THE RFID BADGE. 

Содержание CONNECT QUEUE

Страница 1: ...s Portable Units communicate to the Base Station directly and or through other logged on units forming a communications mesh network to the Base Station The SCOTT CONNECT QUEUE Interface Accessory extends the range for the PDA s by providing another network location to communicate with the Base Station Because of this mesh network system the signal strength of each user as displayed on the Base St...

Страница 2: ...OWER SUPPLY HARD WIRE POWER CORD CONNECT TO VEHICLE 12V or 24V POWER 3 When installed in a vehicle the QUEUE Interface Accessory must be securely mounted in either a vertical or horizontal position using the mounting holes pro vided Use 10 flat head machine screws in a minimum of four 4 of the holes two on each end Recommended torque is 2 5 ft lbs or 30 inch lbs 4 Power supply considerations a For...

Страница 3: ...REDUCE THE PERFORMANCE OF THE EQUIPMENT WHICH MAYRESULT IN SERIOUS INJURY OR DEATH 5 Align the pins in the connector with the socket and thread the collar on until snug Use no tools to tighten 6 All wiring must be secured and must not provide a hazard to tripping or entangle ment in the chosen location All wiring must be protected to prevent abrasion or other damage 7 Install the 2 4 GHZ Antenna S...

Страница 4: ...arment such as inside a sleeve RFID BADGE RFID TAG RFID BUTTON Resources added this way will not be automatically able to receive communications from the system Special consideration must be given to resources who appear on the system using one of these methods Any Firefighter Resources logged into the QUEUE Interface accessory will be added to the accountability system when the QUEUE Interface co...

Страница 5: ...verify that all resources have received the message to EVACUATE before pressing the ACK button to send an Acknowledge message to the Accountability System Base Station and silence the Warning Sound The SWIPE AREA is used to either log in or log out to the QUEUE Interface If the QUEUE Interface is removed on the current Accountability System Base Station the RANGE light will show YELLOW as the QUEU...

Страница 6: ...ding tones FAILED SCAN If a SWIPE in OR out is unsuccessful there will be NO FLASH and NO SOUND USE WITH THE BASE STATION 1 Turn on the Base Station computer with the SCOTT IMPERIUM Accountability Software with the PCMCIA Communications Card or USB GATEWAY Commu nications Interface installed Refer to the Base Station Instructions 2 When the QUEUE Interface Accessory establishes communication with ...

Страница 7: ...event or who are known to have left the event can be deleted as follows 1 With the Entry for the QUEUE Interface showing on the TACTICAL Screen open the TEAM DETAILS to see all individuals who are logged into the QUEUE Interface 2 Click the EDIT Tool Pencil and SELECT the individual or individuals to be deleted from the Entry for the QUEUE Interface 3 Drag the selected individuals out of the Entry...

Страница 8: ...ed to the computer with the USB interface cable 2 Verify that the QUEUE Interface is connected to an active power supply CONNECT THE USB CABLE CONNECT THE POWER TWO VERSIONS UNIVERSAL POWER CORD CONNECT TO POWER SUPPLY HARD WIRE POWER CORD CONNECT TO VEHICLE 12V or 24V POWER 3 Start up the personal computer in accordance with the computer s user instruc tions The computer will display a message th...

Страница 9: ...Interface Accessory is programmed at the factory to a default identification ID To change the ID of a QUEUE Interface Accessory proceed as follows 1 The current name of the QUEUE Interface will appear in the space below the picture 2 To rename the QUEUE Interface type a new name maximum eight characters alpha numeric in the Field Repeater ID 3 Select Apply to change the name If suc cessful the GRE...

Страница 10: ...sired operation FCC Warning Part 15 21 Changes or modifications not expressly approved by the party responsible for compli ance could void the user s authority to operate the equipment The SCOTT CONNECT QUEUE Interface Accessory Transmitter has been as signed FCC ID T5E 201211 RADIO FREQUENCY INTERFERENCE RFI When any electronic device is adversely affected by radio waves Radio Frequency Interfere...

Страница 11: ...ation of the device LA DÉCLARATION DE CONFORMITÉ D INDUSTRIE DE CANADA Déclaration D Industrie De Canada Le terme avant de la certification le nombre d enregistrement signifie seulement que les spécifications techniques d Industrie du Canada ont été rencontrées Sectionner 14 de RSS 210 Le programme d installation de cet équipement de radio doit garantir que l antenne est localisée ou tel est indiq...

Страница 12: ...of the equipment is noted remove the equipment from service and tag for repair by authorized personnel Notify all personnel that the unit is out of service and take alternate steps to account for the appli cable personnel CLEANING MAINTENANCE AND STORAGE Clean the exterior of the SCOTT CONNECT QUEUE Interface Accessory by wiping with a damp sponge and thoroughly wiping dry No attempt shall be made...

Отзывы: