Page 2 of 12
P/N 595284-01 Rev A 9/13
INSTALLATION OF THE
SCOTT ACCOUNTABILITY SYSTEM
QUEUE INTERFACE ACCESSORY
The QUEUE Interface Accessory, SCOTT P/N 201211-01, must be properly
installed and powered to operate correctly.
If you have any questions about installing the QUEUE Interface assembly, consult a qualified
electrician before proceeding.
1. Choose a suitable location for the QUEUE Interface Accessory:
a) Mount the assembly will be readily accessible but will not pose a hazard to
occupants of the vehicle.
b) Choose a location where the QUEUE Interface Accessory will not be exposed
to excess moisture.
c) The mounting surface should be flat so that tightening the mounting screws
will not bend or stress the back plate of the QUEUE Interface.
2. Place the QUEUE Interface Accessory in the desired position and mark the six
(6) mounting holes through the two mounting tabs on the housing.
WARNING
WHEN INSTALLING WITHIN A VEHICLE,
DO NOT MOUNT THE QUEUE INTERFACE
ACCESSORY IN A LOCATION WHERE IT
MAY PRESENT A HAZARD TO OCCUPANTS
OF THE VEHICLE. FAILURE TO PROPERLY
LOCATE AND PROPERLY MOUNT THE
QUEUE INTERFACE ASSEMBLY MAY RESULT
IN SERIOUS INJURY.
CONNECT THE POWER (TWO VERSIONS)
UNIVERSAL POWER
CORD (CONNECT
TO POWER SUPPLY)
HARD WIRE POWER CORD
(CONNECT TO VEHICLE
12V or 24V POWER)
3. When installed in a vehicle, the QUEUE Interface Accessory must be securely
mounted in either a vertical or horizontal position using the mounting holes pro-
vided. Use #10 flat head machine screws in a minimum of four (4) of the holes
(two on each end). Recommended torque is 2.5 ft-lbs. or 30 inch-lbs.
4. Power supply considerations:
a) For use with the 100–240 VAC power converter, use only QUEUE Interface
Wall Power Assembly P/N 201332-01. Choose a location for mounting the as-
sembly where the power source necessary can be reached within the length
of the power supply cord which is approximately six (6) feet.
b) When powered by 12 VDC supplied from the vehicle, use only SCOTT Hard
Wire Power Cord P/N 201222-01. Attach the ring terminals to the appropriate
power terminals on the vehicle. The Hard Wire Power Cord is approximately
12 feet long and is equipped with an in-line fuse which uses a blade style low-
voltage 2 amp fuse, SCOTT P/N 31002883.
MOUNTING
HOLES
MOUNTING
HOLES
CAUTION
THE QUEUE INTERFACE ACCESSORY
MUST BE INSTALLED AT LEAST THREE (3)
FEET AWAY FROM WHERE AN RFID CARD
READER/WRITER MAY BE USED. CLOSE
PROXIMITY OF THE QUEUE INTERFACE MAY
CAUSE THE RFID CARD READER/WRITER
TO MALFUNCTION. FAILURE TO RECOGNIZE
A MALFUNCTION OF THE RFID CARD
READER/WRITER AND TAKE THE PROPER
CORRECTIVE ACTION MAY RESULT A FAILED
READ/WRITE OF THE RFID BADGE.