OPERATION AND MAINTENANCE INSTRUCTIONS

SCOTT CONNECT

QUEUE Interface Accessory

DESCRIPTION

The SCOTT CONNECT QUEUE Interface Accessory provides a log-in interface 

for SCOTT IMPERIUM Accountability System users that can be associated with 

a particular vehicle (such as a fire truck) at an event where accountability of 

participating personnel is required. By swiping a SCOTT Accountability System 

programmed ID Badge, Tag, or Button, the ID’s of up to twelve (12) users 

can be stored and downloaded to the Accountability System Base Station. 
The SCOTT CONNECT QUEUE Interface Accessory is 

ONLY

 compatible 

with an Accountability System Base Station that is using either a PCMCIA 

Gateway, SCOTT P/N 200732-02, or a USB Gateway, SCOTT P/N 201088-02 

with the IMPERIUM Accountability Software.
Resources who are not using a properly equipped SCOTT SCBA respirator 

may be added to the system for accountability purposes by using SCOTT 

Programmable ID Tags with either the QUEUE Interface or an RFID TAG 

READER/WRITER accessory. Resources added this way will not automatically 

be able to receive communications from the system. Special consideration 

must be given to resources who appear on the system using one of these 

methods. The Base Station Operator must verify that all personnel who 

appear as logged into the QUEUE Interface Accessory are actually present 

at the event.
When activated, the SCOTT CONNECT QUEUE Interface Accessory appears 

on the SCOTT IMPERIUM Accountability Software Base Station Display as 

the identification name of the vehicle. The QUEUE Interface Accessory then 

downloads to the base station the ID information of all participants who 

have logged into the unit. When these individuals are included in the event 

activities, they appear on the Tactical Display Screen much like a SEMS II 

PDA user, except that the user details such as Air Pressure will not display. 
The SCOTT CONNECT QUEUE Interface Accessory can be placed up to 

seven tenths (0.7) mile line-of-sight from the base station. When logged on, 

all the SEMS II Personal Distress Alarms (PDA’s) Portable Units communicate 

to the Base Station directly and/or through other logged on units forming a 

communications “mesh network” to the Base Station. The SCOTT CONNECT 

QUEUE Interface Accessory extends the range for the PDA’s by providing 

another network location to communicate with the Base Station. Because of 

this mesh network system, the signal strength of each user as displayed on 

the Base Station may change as the network constantly re-adjusts to the 

movement of the users. For identification purposes, the SCOTT CONNECT 

QUEUE Interface Accessory comes factory programmed with an eight digit 

ID number that will be displayed. This default number can be reprogrammed. 

Refer to the UPDATE QUEUE Interface ID section of this instruction for details.

© 2013 Scott Safety.

SCOTT, the SCOTT SAFETY Logo, Scott Health and Safety, SEMS, IMPERIUM, and QUEUE are registered and/or unregistered 

marks of Scott Technologies, Inc. or its affiliates.

WARNING

THE SCOTT ACCOUNTABILITY SYSTEM IS INTENDED FOR USE WITH PROPERLY EQUIPPED SCOTT SELF-CONTAINED 

BREATHING APPARATUS (SCBA) WHICH MAY SUPPORT HUMAN LIFE IN HAZARDOUS ATMOSPHERES. FAILURE TO CAREFULLY 

READ AND UNDERSTAND THE FOLLOWING INSTRUCTIONS MAY RESULT IN SERIOUS INJURY OR DEATH TO THE SCBA USER.

USE OF THE SCOTT CONNECT QUEUE INTERFACE ACCESSORY WILL REQUIRE MODIFICATION OF THE RESPIRATOR 

"REGULAR OPERATIONAL INSPECTION PROCEDURES"  AND WILL REQUIRE TRAINING OF THE RESPIRATOR USER IN THE 

USE OF SUCH EQUIPMENT.

THE FOLLOWING INSTRUCTIONS SUPPLEMENT BUT DO NOT REPLACE THE OPERATING AND MAINTENANCE INSTRUCTIONS 

SUPPLIED WITH EACH RESPIRATOR.

CAUTION

ONLY THE -02 VERSIONS OF THESE SCOTT 

GATEWAYS WILL OPERATE WITH THE 

IMPERIUM SOFTWARE AND PROVIDE FULL 

FUNCTIONALITY OF THE SYSTEM FEATURES 

AND THE QUEUE INTERFACE ACCESSORY. 

DO NOT USE WITH THE -01 VERSIONS 

OF THESE ITEMS. IF YOU HAVE THE -01 

VERSIONS OF THESE GATEWAYS, CONTACT 

SCOTT OR YOUR SCOTT DISTRIBUTOR FOR 

DETAILS.

WARNING

SPECIAL CONSIDERATION MUST BE GIVEN 

TO RESOURCES WHO APPEAR ON THE 

SYSTEM USING ONE OF THE TAG READING 

METHODS. THE BASE STATION OPERATOR 

MUST VERIFY THAT ALL PERSONNEL WHO 

APPEAR AS LOGGED INTO THE QUEUE 

INTERFACE ACCESSORY ARE ACTUALLY 

PRESENT AT THE EVENT. FAILURE TO 

DO SO MAY RESULT PRESENTATION OF 

INACCURATE INFORMATION WHICH COULD 

LEAD TO SERIOUS INJURY OR DEATH.

Содержание CONNECT QUEUE

Страница 1: ...s Portable Units communicate to the Base Station directly and or through other logged on units forming a communications mesh network to the Base Station The SCOTT CONNECT QUEUE Interface Accessory extends the range for the PDA s by providing another network location to communicate with the Base Station Because of this mesh network system the signal strength of each user as displayed on the Base St...

Страница 2: ...OWER SUPPLY HARD WIRE POWER CORD CONNECT TO VEHICLE 12V or 24V POWER 3 When installed in a vehicle the QUEUE Interface Accessory must be securely mounted in either a vertical or horizontal position using the mounting holes pro vided Use 10 flat head machine screws in a minimum of four 4 of the holes two on each end Recommended torque is 2 5 ft lbs or 30 inch lbs 4 Power supply considerations a For...

Страница 3: ...REDUCE THE PERFORMANCE OF THE EQUIPMENT WHICH MAYRESULT IN SERIOUS INJURY OR DEATH 5 Align the pins in the connector with the socket and thread the collar on until snug Use no tools to tighten 6 All wiring must be secured and must not provide a hazard to tripping or entangle ment in the chosen location All wiring must be protected to prevent abrasion or other damage 7 Install the 2 4 GHZ Antenna S...

Страница 4: ...arment such as inside a sleeve RFID BADGE RFID TAG RFID BUTTON Resources added this way will not be automatically able to receive communications from the system Special consideration must be given to resources who appear on the system using one of these methods Any Firefighter Resources logged into the QUEUE Interface accessory will be added to the accountability system when the QUEUE Interface co...

Страница 5: ...verify that all resources have received the message to EVACUATE before pressing the ACK button to send an Acknowledge message to the Accountability System Base Station and silence the Warning Sound The SWIPE AREA is used to either log in or log out to the QUEUE Interface If the QUEUE Interface is removed on the current Accountability System Base Station the RANGE light will show YELLOW as the QUEU...

Страница 6: ...ding tones FAILED SCAN If a SWIPE in OR out is unsuccessful there will be NO FLASH and NO SOUND USE WITH THE BASE STATION 1 Turn on the Base Station computer with the SCOTT IMPERIUM Accountability Software with the PCMCIA Communications Card or USB GATEWAY Commu nications Interface installed Refer to the Base Station Instructions 2 When the QUEUE Interface Accessory establishes communication with ...

Страница 7: ...event or who are known to have left the event can be deleted as follows 1 With the Entry for the QUEUE Interface showing on the TACTICAL Screen open the TEAM DETAILS to see all individuals who are logged into the QUEUE Interface 2 Click the EDIT Tool Pencil and SELECT the individual or individuals to be deleted from the Entry for the QUEUE Interface 3 Drag the selected individuals out of the Entry...

Страница 8: ...ed to the computer with the USB interface cable 2 Verify that the QUEUE Interface is connected to an active power supply CONNECT THE USB CABLE CONNECT THE POWER TWO VERSIONS UNIVERSAL POWER CORD CONNECT TO POWER SUPPLY HARD WIRE POWER CORD CONNECT TO VEHICLE 12V or 24V POWER 3 Start up the personal computer in accordance with the computer s user instruc tions The computer will display a message th...

Страница 9: ...Interface Accessory is programmed at the factory to a default identification ID To change the ID of a QUEUE Interface Accessory proceed as follows 1 The current name of the QUEUE Interface will appear in the space below the picture 2 To rename the QUEUE Interface type a new name maximum eight characters alpha numeric in the Field Repeater ID 3 Select Apply to change the name If suc cessful the GRE...

Страница 10: ...sired operation FCC Warning Part 15 21 Changes or modifications not expressly approved by the party responsible for compli ance could void the user s authority to operate the equipment The SCOTT CONNECT QUEUE Interface Accessory Transmitter has been as signed FCC ID T5E 201211 RADIO FREQUENCY INTERFERENCE RFI When any electronic device is adversely affected by radio waves Radio Frequency Interfere...

Страница 11: ...ation of the device LA DÉCLARATION DE CONFORMITÉ D INDUSTRIE DE CANADA Déclaration D Industrie De Canada Le terme avant de la certification le nombre d enregistrement signifie seulement que les spécifications techniques d Industrie du Canada ont été rencontrées Sectionner 14 de RSS 210 Le programme d installation de cet équipement de radio doit garantir que l antenne est localisée ou tel est indiq...

Страница 12: ...of the equipment is noted remove the equipment from service and tag for repair by authorized personnel Notify all personnel that the unit is out of service and take alternate steps to account for the appli cable personnel CLEANING MAINTENANCE AND STORAGE Clean the exterior of the SCOTT CONNECT QUEUE Interface Accessory by wiping with a damp sponge and thoroughly wiping dry No attempt shall be made...

Отзывы: