Code or Light Action
Probable Cause
Suggested Action
O
Unit manually switched off
If desired, switch unit on.
F
Freeze mode
None, unit is making ice.
b
Bin sensors sense bin full
Check if bin is full.
E
Corrupted memory
Replace controller
C
Clean mode
Continue clean mode
d
Test mode
None, allow unit to finish test
mode.
1
Auger motor rotated auger
backwards.
Replace auger motor. Check water
seal area for leaks, replace seal if
leaking.
2
Auger motor stalled or operating
slowly
Clean ice making system and retry.
If unit shuts off again right after a
reset, magnet rotor on motor shaft
may be loose.
3
No water in reservoir
Restore water. If there is water,
is it too pure? Are sensor wires
connected?
4
High pressure cut out open
Check fan motor on air cooled or
water supply on water cooled.
Status light is on
Unit is in ice making mode
Normal, may not be making ice if
bin is full
Time to Clean light is on
Unit has not been cleaned for at
least 6 months
Clean unit
Auger light is on
Auger motor is active
Normal when making ice
Compressor light is on
Compressor is active
Normal when making ice
Code E cannot be corrected in the field. Replace controller.
Controller Diagnostics
Содержание UF424A-1A
Страница 1: ...Technical Manual for Model UF424 and UN324 ...
Страница 33: ...UF424 UN324 Technical Manual September 2017 Page 33 Schematic Diagram ...
Страница 34: ...UF424 UN324 Technical Manual September 2017 Page 34 Wiring Diagram ...
Страница 35: ...SCOTSMAN ICE SYSTEMS 101 Corporate Woods Parkway Vernon Hills IL 60061 800 726 8762 www scotsman ice com ...