UF0915, 1415, 2020 and UN0815, 1215, 1520 User Manual
October 2019
Page 4
This appliance is intended to be used in commercial
applications including:
• Restaurant kitchens
• Bars
• Hotels
Dimensions and Electrical:
Location:
The unit can be built into a cabinet as the air flow
is in and out the front.
The front of the machine
must not be blocked.
Certain maintenance or
repair procedures will require removal of the top,
back and side panels, so plan ahead for service and
maintenance needs.
Spacing:
No additional spacing is required at the top or sides.
However, suggested minimum side clearance for
installation is 1/8 inch or 3 mm and suggested
minimum top clearance is 1/4 inch or 7 mm.
Allow 4 inches (100 mm) minimum space at the back
for the utility connections. Do not block louvers at the
front of the cabinet.
Air OUT
Air IN
Model
Electrical
(volts/Hz/Phase
Ice Form
Width
(in / cm)
Depth
(in/cm)
Height (w/o legs)
(in/cm)
Power
Cord
UN0815A-1A
115/60/1
Nugget
15 / 38
23.7 / 60.3 31.94 / 81.1
5-15P
UN1215A-1A
115/60/1
Nugget
15 / 38
23.7 / 60.3 31.94 / 81.1
same
UN1520A-1A
115/60/1
Nugget
20 / 51
23.7 / 60.3 31.94 / 81.1
same
UF0915A-1A
115/60/1
Flake
15 / 38
23.7 / 60.3 31.94 / 81.1
same
UF1415A-1A
115/60/1
Flake
15 / 38
23.7 / 60.3 31.94 / 81.1
same
UF2020A-1A
115/60/1
Flake
20 / 51
23.7 / 60.3 31.94 / 81.1
same
Pre-Installation